CAPILLARITY OF CONCRETE INCORPORATING FOUNDRY SAND AS REPLACEMENT OF SAND

Pages
1224–1230
Publication Date
2011-05-01
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

There was an increase in capillary water absorption (C.W.A), a decrease in compressive strength and ultrasonic pulse velocity (U.P.V) with the increase in used foundry sand content in concrete.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The potential uses and the high cost of land-filling of used foundry sands have prompted research into their beneficial reuse.
📊
Key Findings & Data:Capillary water absorption, compressive strength and ultrasonic pulse velocity at 28 days of curing were reported in this investigation.
💡
Conclusion & Impact:There was an increase in capillary water absorption (C.W.A), a decrease in compressive strength and ultrasonic pulse velocity (U.P.V) with the increase in used foundry sand content in concrete.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Foundry Sands · CAPYLLARY WATER ABSORPTYON · Durability

Abstract

The potential uses and the high cost of land-filling of used foundry sands have prompted research into their beneficial reuse. This paper presents the results of experimental research into concrete produced by replacing the natural aggregates with recycled aggregates coming from foundry industries. Little work has been done so far on the effect of used foundry sand on the durability of concrete especially water absorption. The main aim of this work was to determine capillary water absorption and methods of improvement. Capillary water absorption, compressive strength and ultrasonic pulse velocity at 28 days of curing were reported in this investigation. The natural was replaced with 0%, 30%, 60% and 100% with foundry sand. Coarse natural aggregate was used in all cases and the amount of cement and W/C ratio of 0.5 remained constant in the all mixes. There was an increase in capillary water absorption (C.W.A), a decrease in compressive strength and ultrasonic pulse velocity (U.P.V) with the increase in used foundry sand content in concrete.

Özet

The potential uses and the high cost of land-filling of used foundry sands have prompted research into their beneficial reuse. This paper presents the results of experimental research into concrete produced by replacing the natural aggregates with recycled aggregates coming from foundry industries. Little work has been done so far on the effect of used foundry sand on the durability of concrete especially water absorption. The main aim of this work was to determine capillary water absorption and methods of improvement. Capillary water absorption, compressive strength and ultrasonic pulse velocity at 28 days of curing were reported in this investigation. The natural was replaced with 0%, 30%, 60% and 100% with foundry sand. Coarse natural aggregate was used in all cases and the amount of cement and W/C ratio of 0.5 remained constant in the all mixes. There was an increase in capillary water absorption (C.W.A), a decrease in compressive strength and ultrasonic pulse velocity (U.P.V) with the increase in used foundry sand content in concrete.

🔖

Cite This Article

Khatib, J. M., Herkı, B. A., Fırat, S., Menadi, B., Kenai, S. (2011). CAPILLARITY OF CONCRETE INCORPORATING FOUNDRY SAND AS REPLACEMENT OF SAND. Engineering Sciences, Cilt: 6 Sayı: 4, 1224–1230. https://doi.org/10.12739/nwsaes.v6i4.5000066934