Journals / Van Diş Hekimliği Dergisi / 2023 / Cilt: 4 Sayı: 1

Can Calcium Phosphate Be Used as a Model Material for Implant Stability Evaluation?

İmplant Stabilitesi Değerlendirmesinde Model Materyali Olarak Kalsiyum Fosfat Kullanılabilir mi?

Pages
1–8
Publication Date
2023-08-07
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In this study, it was revealed that calcium phosphate can be used as a model material in in vitro implant studies and in the evaluation of implant stability.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The aim of this study was to evaluate the use of calcium phosphate graft material as an implant model.
📊
Key Findings & Data:This prospective, single-blind, model study was carried out in Van Yüzüncü Yıl University Faculty of Dentistry, Oral and Maxillofacial Surgery clinic in February 2023.
💡
Conclusion & Impact:In this study, it was revealed that calcium phosphate can be used as a model material in in vitro implant studies and in the evaluation of implant stability.
🔬Design:Modeling & Simulation
📍Scope:2023 Verileri
⚙️Variables:Kalsiyum fosfat · dental implant · kemik modeli

Abstract

The aim of this study was to evaluate the use of calcium phosphate graft material as an implant model. This prospective, single-blind, model study was carried out in Van Yüzüncü Yıl University Faculty of Dentistry, Oral and Maxillofacial Surgery clinic in February 2023. Calcium phosphate graft was prepared as the model material and 2 molds in Group 1 were left to set for 1 hour and 2 molds in Group 2 for 12 hours. A total of 48 implant sockets were created in 24 randomly generated groups. The results were evaluated at the 95% confidence interval and the significance level of p<0.05. Drilling times of the implant sockets in the 12-hour model group were found to be statistically significantly higher than those in the 1-hour model group (p<0.01). Implant placement torques in the implant sockets in the 12-hour model group were found to be statistically significantly higher than those in the 1-hour model group (p<0.01). In this study, it was revealed that calcium phosphate can be used as a model material in in vitro implant studies and in the evaluation of implant stability.

Özet

Bu çalışmanın amacı kalsiyum fosfat greft materyalinin implant modeli olarak kullanımını değerlendirmekti. Bu prospektif, tek kör, model çalışması Van Yüzüncü Yıl Üniversitesi Diş Hekimliği Fakültesi Ağız Diş ve Çene Cerrahisi kliniğinde Şubat 2023 tarihinde gerçekleştirildi. Kalsiyum fosfat greft model materyali olarak hazırlandı ve Grup 1’deki 2 kalıp 1 saat ve Grup 2’deki 2 kalıp 12 saat sertleşmesi için bekletildi. Rastgele oluşturulan gruplarda 24 adet toplamda 48 implant yuvası oluşturuldu. Sonuçlar % 95’lik güven aralığında, anlamlılık p<0.05 düzeyinde değerlendirildi. 12 saatlik model grubundaki implant yuvalarının drilleme zamanları 1 saatlik model grubundakilerden istatistiksel olarak anlamlı seviyede yüksek saptanmıştır (p<0,01). 12 saatlik model grubundaki implant yuvalarındaki implant yerleştirme torkları 1 saatlik model grubundakilerden istatistiksel olarak anlamlı seviyede yüksek saptanmıştır (p<0,01). Bu çalışmada kalsiyum fosfatın in vitro implant çalışmalarında, implant stabilitesinin değerlendirilmesinde model materyali olarak kullanılabileceği ortaya koyuldu.

🔖

Cite This Article

CİĞERİM, L., ORHAN, Z. D., KAHRAMAN, N. H., ALSMADI, M., BSAILEH, M. (2023). Can Calcium Phosphate Be Used as a Model Material for Implant Stability Evaluation?. Van Diş Hekimliği Dergisi, Cilt: 4 Sayı: 1, 1–8. https://ajindex.com/articles/978523

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (9)

  1. Singh K, Rao J, Afsheen T, Tiwari B. Survival rate of dental implant placement by conventional or flapless surgery in controlled type 2 diabetes mellitus patients: A systematic review. Indian J Dent Res. 2019;30(4):600- 611
  2. Jivraj S, Chee W. Rationale for dental implants. Br Dent J. 2006;200(12):661-665
  3. Setzer FC, Kim S. Comparison of Long-term Survival of Implants and Endodontically Treated Teeth. Journal of Dental Research. 2014;93(1):1926
  4. Salvi, G. E.,Monje, A., &Tomasi, C. Longterm biological compli- cations of dental implants placed either inpristineor in augmentedsites: A systematic review and metaanalysis. Clin Oral Implants Res.2018;29(Suppl 16):294–310
  5. Eriksson R, Albrektsson T: Temperature thres holds for heat- induced bone tissue injury: A vital-microscopic study in the rabbit. J Prosthet Dent. 1983;50:101
  6. Ercoli C, Funkenbusch PD, Lee H-J, Moss ME, Graser GN. The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: a study of drill dura- bility. Int J Oral Maxillofac Implants.2004;19:335–349. 7.Sharawy M, Misch CE, Weller N, Tehemar S. Heat generation during implant drilling: The significance of motor speed. J Oral Maxillofac Surg 2002;60:1160‐1169. 8(12). Watanbe F, Tawada Y, Komatsu S, Hata Y. Heatdistri- bution in bone during preparation of implantsites: heat analysis by real-time thermography. Int J Oral Maxillofac Implants.1992;7:212–219 9. Möhlhenrich SC, Modabber A, Steiner T, Mitchell DA, Hölzle F. Heat generation and drill wear during dental implant site preparation: systematic review. Br J Oral Maxillofac Surg. 2015;53(8): 679–689
  7. Reingewirtz Y, Szmukler-Moncler S, Senger B: Influence of different parameters on bone heating and drilling in implantology. Clin Oral Implant Res. 1997;8:189
  8. Yeniyol S, Jimbo R, Marin C, Tovar N, Janal MN, Coelho PG. The effect of drilling speed on early bone healing to oral implants. Oral Surg Oral Med Oral Pathol Oral Radiol. 2013;116:550-555
  9. Iyer S, Weiss C, Mehta A. Effects of drill speed on heat production and the rate and quality of bone formation in dental implant osteotomies, part I: relationship between drill speed and heat production. Int J Prosthodont. 1997;10:411-414. 13.Gaspar J, Borrecho G, Oliveira P, Salvado F, Martinsdos Santos J. Osteotomy at low-speed drilling without irrigation versus high-speed drilling with irrigation: an experimental study. Acta Med Port. 2013;26:231-6. 14.Möhlhenrich