Journals / Journal of Health Sciences and Medicine / 2023 / Cilt: 6 Sayı: 5

Ultrasonic shear-wave elastography: a novel method for assessing the tumor grade in endometrial cancer: a prospective study

Pages
987–992
Publication Date
2023-09-28
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion: Real-time shear-wave elastography is a promising tool to predict the grade 3 tumors and deep myometrial invasion in endometrial cancer patients.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Aims: To evaluate the diagnostic performance of the real time shear-wave elastography in patients with endometrial cancer in terms of tumor grade and myometrial invasion depth preoperatively.
📊
Key Findings & Data:Methods: In this prospective observational study, forty-eight women who were diagnosed with endometrioid type endometrium cancer in our gynecologic oncology clinic of a tertiary hospital between September 2020-January 2021 in Turkey.
💡
Conclusion & Impact:Conclusion: Real-time shear-wave elastography is a promising tool to predict the grade 3 tumors and deep myometrial invasion in endometrial cancer patients.
🔬Design:Research Article
📍Scope:2020 Verileri
⚙️Variables:Endometrial cancer · Shear-wave elastography · shear-wave

Abstract

Aims: To evaluate the diagnostic performance of the real time shear-wave elastography in patients with endometrial cancer in terms of tumor grade and myometrial invasion depth preoperatively. Methods: In this prospective observational study, forty-eight women who were diagnosed with endometrioid type endometrium cancer in our gynecologic oncology clinic of a tertiary hospital between September 2020-January 2021 in Turkey. All patients underwent an ultrasonographic shear-wave measurements. Mean shear-wave values were measured from the tumor itself. Mean elasticity values were assessed in terms of tumor grade and myometrial invasion depth. Results: The median [%25-%75] shearwave value of the participants was 29.45kPa (5.02-167.21). Shear-wave value for grade 3 endometrial cancer showed a statistically significant difference compared to grade 1 and 2 shear-wave values (p<0.001). To determine the myometrial invasion depth, lymph node involvement, lympho-vascular stromal invasion and cervical stromal invasion statues, shear-wave measurements did not show a significant result (p>0.05). ROC curve analysis showed significant results to determine the myometrial invasion depth and grade 3 endometrial cancer with the mean shear-wave cut-off values of 28.29 kPa and 57 kPa respectively (p<0.001). Conclusion: Real-time shear-wave elastography is a promising tool to predict the grade 3 tumors and deep myometrial invasion in endometrial cancer patients.

🔖

Cite This Article

DESTEGÜL, E., PEKÖZ, B. Ç., SEYFETTİNOĞLU, S., BAŞ, S., ADIGÜZEL, F. I., NARİN, M. (2023). Ultrasonic shear-wave elastography: a novel method for assessing the tumor grade in endometrial cancer: a prospective study. Journal of Health Sciences and Medicine, Cilt: 6 Sayı: 5, 987–992. https://ajindex.com/articles/964491

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (3)

  1. Siegel RL, Miller KD, Jemal A. Cancer statistics, 2019. CA Cancer J Clin. 2019;69(1):7-34. doi:10.3322/caac.21551 Vitale SG, Capriglione S, Zito G, et al. Management of endometrial, ovarian and cervical cancer in the elderly: current approach to a challenging condition. Arch Gynecol Obstet. 2019;299(2):299-315. doi:10.1007/s00404-018-5006-z Health UNIo. National Cancer Institute, DCCPS, Surveillance Research Program, Cancer Statistics Branch. Surveillance, Epidemiology, and End Results (SEER). Program Research Data (1973-2008). 2015. Sorosky JI. Endometrial cancer. Obstet Gynecol. 2012;120(2 Pt 1):383-397. doi:10.1097/AOG.0b013e3182605bf1 Krouskop TA, Dougherty DR, Vinson FS. A pulsed Doppler ultrasonic system for making noninvasive measurements of the mechanical properties of soft tissue. J Rehabil Res Dev. 1987;24(2):1-8.
  2. Lerner RM, Huang SR, Parker KJ. "Sonoelasticity" images derived from ultrasound signals in mechanically vibrated tissues. Ultrasound Med Biol. 1990;16(3):231-239. doi:10.1016/0301-5629(90)90002-t Emelianov SY, Lubinski MA, Weitzel WF, Wiggins RC, Skovoroda AR, O'Donnell M. Elasticity imaging for early detection of renal pathology. Ultrasound Med Biol. 1995;21(7):871-883. doi:10.1016/0301-5629(94)00146-5
  3. Ophir J, Cespedes I, Ponnekanti H, Yazdi Y, Li X.eElastography: a quantitative method for imaging the elasticity of biological tissues. Ultrason Imaging. 1991;13(2):111-134. doi:10.1177/ 016173469101300201 Shiina T, Nightingale KR, Palmeri ML, et al. WFUMB guidelines and recommendations for clinical use of ultrasound elastography: Part 1: basic principles and terminology. Ultrasound Med Biol. 2015;41(5):1126-1147. doi:10.1016/j.ultrasmedbio.2015.03.009 Liu Z, Jing H, Han X, et al. Shear wave elastography combined with the thyroid imaging reporting and data system for malignancy risk stratification in thyroid nodules. Oncotarget. 2017;8(26):43406-43416. doi:10.18632/oncotarget.15018 Lee HY, Lee JH, Shin JH, et al. Shear wave elastography using ultrasound: effects of anisotropy and stretch stress on a tissue phantom and in vivo reactive lymph nodes in the neck. Ultrasonography. 2017;36(1):25-32. doi:10.14366/usg.16003 Ariji Y, Nakayama M, Nishiyama W, Nozawa M, Ariji E. Shear-wave sonoelastography for assessing masseter muscle hardness in comparison with strain sonoelastography: study with phantoms and healthy volunteers. Dentomaxillofac Radiol. 2016;45(2):20150251. doi:10.1259/dmfr.20150251 Chang JM, Won JK, Lee KB, Park IA, Yi A, Moon WK