Journals / Turkish Journal of Analytical Chemistry / 2022 / Cilt: 4 - Sayı: 2

Electrochemical and liquid chromatographic analysis of triamcinolone acetonide in pharmaceutical formulations

Pages
59–66
Publication Date
2022-12-29
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

HPLC-PDA method displayed linearity in 0.1-50µg/mL (2.3×10-7-1.15×10-4 M) concentration range with LOD and LOQ values as 3.992×10-8 and 1.29×10-7M, respectively.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Electrochemical reduction of triamcinolone acetonide on pencil graphite electrode surface was firstly investigated by cyclic voltammetry (CV).
📊
Key Findings & Data:The dependence of cathodic peak current and peak potential on different pH medium and scan rate were investigated.
💡
Conclusion & Impact:HPLC-PDA method displayed linearity in 0.1-50µg/mL (2.3×10-7-1.15×10-4 M) concentration range with LOD and LOQ values as 3.992×10-8 and 1.29×10-7M, respectively.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Triamcinolone acetonide · voltammetry · HPLC-PDA

Abstract

Electrochemical reduction of triamcinolone acetonide on pencil graphite electrode surface was firstly investigated by cyclic voltammetry (CV). The dependence of cathodic peak current and peak potential on different pH medium and scan rate were investigated. The adsorption controlled nature of the peak was achieved. During pH optimization, 0.067 M Phosphate (pH 4.50 to pH 7.50), 0.2 M Acetate (pH 3.50 to 5.50) and 0.04 M Britton Robinson (BR; pH 2.00 to 12.00) buffers were employed as supporting electrolytes. Scan rate optimization was investigated in the range 25-1000 mVs-1 (vs. Ag/AgCl). Maximum peak current was observed in the 0.04 M BR buffer (pH 3.50). Peak current increases and shifts to more cathodic values with the increasing scan rate. Curve of logarithm of peak current (log I) versus logarithm of scan rate (log v) showed linear regression with the equation log(Ip/μA) = 0.8395 log(v/mVs-1)-0.8386 and correlation coefficient (R2: 0.9761). This indicated that slope of the logv-logI curve is close to 1.0 and the cathodic electrode reaction was adsorption controlled, as desirable. The linear range was 1×10-7-5×10-5 M, sensitivity was 1,3347 µA M-1, Limit of detection (LOD) and Limit of quantification (LOQ) were 3.18×10-8 M and 1.00×10-7 M, respectively. HPLC-PDA analysis were performed with H2O:MeOH (28:72, v/v) as mobile phases A and B at a flow rate of 1mL/min at 242nm. Method validation studies were conducted in accordance with ICH Q2(R1) guideline and corresponding results were summarized in tables. HPLC-PDA method displayed linearity in 0.1-50µg/mL (2.3×10-7-1.15×10-4 M) concentration range with LOD and LOQ values as 3.992×10-8 and 1.29×10-7M, respectively.

🔖

Cite This Article

DENİZHAN, N., YILMAZ, S., SAĞLIKOĞLU, G., KILINÇ, E., YENGİN, Ç., DER, F. G. (2022). Electrochemical and liquid chromatographic analysis of triamcinolone acetonide in pharmaceutical formulations. Turkish Journal of Analytical Chemistry, Cilt: 4 - Sayı: 2, 59–66. https://ajindex.com/articles/870920

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. The International Olympic Committee (IOC) “Anti-Doping Rules Applicable to the Games of the XXIX Olympiad”, 2008, 3-9
  2. H. Koç, O. Yüksel, Kadınlarda fiziksel ve fizyolojik performansının değerlendirilmesi, Dumlupınar Üniversitesi Sağlık Bilimleri Dergisi, 9, 2007, 1
  3. A.J.P. van Heugtena, W. de Boer, W.S. de Vries, C.M.A. Markesteijn, H. Vromans, Development and validation of a stability-indicating HPLC-UV method for the determination of triamcinolone acetonide and its degradation products in an ointment formulation, J Pharm Biomed Anal, 149, 2018, 149, 265
  4. S. Sudsakorn, L. Kaplan, D.A. Williams, Simultaneous determination of triamcinolone acetonide and oxymetazoline hydrochloride in nasal spray formulations by HPLC, J Pharm Biomed Anal, 40, 2006, 1273
  5. G.M. Fernandes-Cunha, J.B. Saliba, R.C. Siqueira, R. Jorge, A. Silva-Cunha, Determination of triamcinolone acetonide in silicone oil and aqueous humor of vitrectomized rabbits’ eyes: Application for a pharmacokinetic study with intravitreal triamcinolone acetonide injections (Kenalog®40), J Pharm Biomed Anal, 89, 2014, 24
  6. D. De Orsi, M. Pellegrini, S. Pichini, D. Mattioli, E. Marchei, L. Gagliardi, High-performance liquid chromatography–diode array and electrospray-mass spectrometry analysis of non-allowed substances in cosmetic products for preventing hair loss and other hormone-dependent skin diseases, J Pharm Biomed Anal, 48, 2008, 641
  7. S.A. Doppenschmitt, B. Scheidel, F. Harrison, J.P. Surmann, Simultaneous determination of triamcinolone acetonide and hydrocortisone in human plasma by high-performance liquid chromatography, J Chromatogr B: Biomed Sci Appl, 682, 1996, 79
  8. A.M. di Pietra, V. Andrisano, R. Gotti, V. Cavrini, On-line post-column photochemical derivatization in liquid chromatographic-diode-array detection analysis of binary drug mixtures, J Pharm Biomed Anal, 14, 1996, 1191
  9. H. Tokunaga, T. Kimura, J. Kawamura, Gas chromatographic determination of glucocorticoids as trimethylsilyl ether derivatives, Yakugaku Zasshi, 99(8), 1979, 800
  10. D. Agbaba, D. Zivanov-Stakic, S. Vladimirov, K. Zubac, Determination of triamcinolone, triamcinolone acetonide and fluocinonide in dosage forms, Acta Pol Pharm, 47(1-2), 1990, 15-18
  11. E.R.M. Kedor-Hackmann, E.A.S. Gianotto, M.I.R.M. Santoro, Determination of triamcinolone acetonide in ointment by UV derivative spectrophotometry and high performance liquid chromatography, Anal Lett, 30(10), 1997, 1861
  12. Y.S. El-Sa