Journals / Gazi University Journal of Science Part A: Engineering and Innovation / 2022 / Cilt: 9 - Sayı: 4

Experimental Investigation of Hydro-Mechanical Soil Properties of a Slope Failure

Pages
392–400
Publication Date
2022-12-31
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Finally, the friction angle due to suction was calculated to be 1.7 degrees from the results of dry and saturated shear strength parameters.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:A sudden slope failure occurred in Manisa possibly due to the effect of water infiltration because of a slightly damaged sewage pipe.
📊
Key Findings & Data:Considering that there was no other evidence such as rainfall or any loading conditions to trigger the slope failure, a laboratory investigation on the soil’s unsaturated hydro-mechanical properties was initiated.
💡
Conclusion & Impact:Finally, the friction angle due to suction was calculated to be 1.7 degrees from the results of dry and saturated shear strength parameters.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Unsaturated Soils · Matric Suction · Landslides

Abstract

A sudden slope failure occurred in Manisa possibly due to the effect of water infiltration because of a slightly damaged sewage pipe. Considering that there was no other evidence such as rainfall or any loading conditions to trigger the slope failure, a laboratory investigation on the soil’s unsaturated hydro-mechanical properties was initiated. Slopes are naturally unsaturated soils, and they may lose their stability with increased saturation degrees with water infiltration. Thus, for a proper investigation, the unsaturated hydro-mechanical properties of soils should be determined. The results presented in this study are focused on determining the key parameters to evaluate the slope failure for unsaturated soil conditions. In this regard, hydraulic conductivity and suction characteristics and the shear strength parameters were determined as well as the classical geotechnical properties of the soil. Classification of soil was determined as silty sand which is known to have slight to moderate suction stresses and mostly affected suddenly by water infiltration. A flexible-wall permeability test was run with a falling head procedure and the saturated hydraulic conductivity of the soil sample was measured as 1x10-7 m/s. Suction characteristics were detected by filter paper method, besides, the soil water retention curve of the soil was constructed. The maximum matric suction of the soil was measured as 2887 kPa for an air-dried sample. Following, the shear strength parameters were measured by conventional direct shear test for both dry and soaked conditions. Finally, the friction angle due to suction was calculated to be 1.7 degrees from the results of dry and saturated shear strength parameters.

🔖

Cite This Article

DURUKAN, S., BAŞARI, E. (2022). Experimental Investigation of Hydro-Mechanical Soil Properties of a Slope Failure. Gazi University Journal of Science Part A: Engineering and Innovation, Cilt: 9 - Sayı: 4, 392–400. https://ajindex.com/articles/859469

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (5)

  1. ASTM D3080-11 (2011). Standard test method for direct shear test of soils under consolidated drained conditions. American Society for Testing and Materials, Withdrawn Standart. ASTM D5084-16 (2016). Standard test method for measurement of hydraulic conductivity of saturated porous materials using a flexible wall permeameter. American Society for Testing and Materials, Active Standart. ASTM D5298-16 (2016). Standard test method for measurement of soil potential (suction) using filter paper. American Society for Testing and Materials, Active Standart. Batali, L., & Andreea, C. (2016). Slope Stability Analysis Using the Unsaturated Stress Analysis. Case Study. Procedia Engineering, 143, 284-291. doi:10.1016/j.proeng.2016.06.036 Bai, F. Q., & Liu, S. H. (2012). Measurement of the Shear Strength of an Expansive Soil by Combining a Filter Paper Method and Direct Shear Tests. Geotechnical Testing Journal, 35(3), 451-459. doi:10.1520/GTJ103342 Bulut, R., & Leong, C. (2008). Indirect Measurement of Suction. Geotechnical and Geological Engineering, 26, 633-644. doi:10.1007/s10706-008-9197-0
  2. Chowdhury, R. H., & Azam, S. (2016). Unsaturated shear strength properties of a compacted expansive soil from Regina, Canada. Innovative Infrastructure Solutions, 1, 47. doi:10.1007/s41062-016-0047-2
  3. Durukan, S., & Akıncı, G. (2017). Assessment and statistical evaluation of suction characteristics obtained via filter paper technique on zeolite – bentonite mixtures. Environmental Earth Sciences, 76, 685, 1-13. doi:10.1007/s12665-017-7032-8
  4. Gan, JK-M, & Fredlund D. G., (1995, September 6-8). Shear Strength Behavior of Two Saprolitic Soils. In: Proceedings of the First International Conference on Unsaturated Soils (UNSAT'95), Paris, France. Fattah, M. Y., Salim, N. M., & Irshayyid, E. J. (2017). Determination of the soil–water characteristic curve of unsaturated bentonite–sand mixtures. Environmental Earth Sciences, 76(5), 201. doi:10.1007/s12665-017-6511-2
  5. Fredlund, D. G., Morgenstern, N. R., & Widger, R. A. (1978). The shear strength of unsaturated soils. Canadian Geotechnical Journal, 15(3), 313-321. doi:10.1139/t78-029 Intrieri, E., Gigli, G., Mugnai, F., Fanti, R., & Casagli, N. (2012). Design and implementation of a land-slide early warning system. Engineering Geology. 147-148, 124-136. doi:10.1016/j.enggeo.2012.07.017 Jewell, R. A. & Wroth, C. P. (1987). Direct shear tests on reinforced sand. Geotechnique, 37(1), 53-68. doi:10.1680/geot.1987.37.1.53 McCartney, J. S., Villar,