Journals / Health Sciences Quarterly / 2019 / Cilt: 3 - Sayı: 4

VOLTAMMETRIC AND CHROMATOGRAPHIC DETERMINATION OF NAPROXEN IN DRUG FORMULATION

Pages
299–310
Publication Date
2019-10-29
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

These two methods were compared in terms of accuracy, precision and recovery studies.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this work, the electrochemical oxidation of naproxen (NAP) was studied at an ultra-trace graphite electrode (UTGE).
📊
Key Findings & Data:Acetate buffer (pH 4.50) was selected as the support electrolyte due to obtaining the highest electronic signal increase during oxidation of NAP at UTGE.
💡
Conclusion & Impact:These two methods were compared in terms of accuracy, precision and recovery studies.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:commercial drug tablets. · naproxen · voltammetric method

Abstract

In this work, the electrochemical oxidation of naproxen (NAP) was studied at an ultra-trace graphite electrode (UTGE). The cyclic voltammetry (CV) technique was used to determine the optimum conditions and the effect of pH on the electrochemical oxidation of NAP. Acetate buffer (pH 4.50) was selected as the support electrolyte due to obtaining the highest electronic signal increase during oxidation of NAP at UTGE. The differential pulse voltammetry (DPV) technique was performed for electrochemical determination of NAP. In the optimum conditions, the limits of detection (LOD) and quantification (LOQ) were determined to be 8.6610-8 M and 2.8810-7 M. In addition, the amount of NAP was determined in drug tablets. The recovery studies of NAP from the drug tablet were completed in order to check the accuracy and precision of the applied voltammetric method. Furthermore, the determination of NAP was performed with the high-performance liquid chromatography (HPLC) method. These two methods were compared in terms of accuracy, precision and recovery studies.

Özet

In this work, the electrochemical oxidation of naproxen (NAP) was studied at an ultra-trace graphite electrode (UTGE). The cyclic voltammetry (CV) technique was used to determine the optimum conditions and the effect of pH on the electrochemical oxidation of NAP. Acetate buffer (pH 4.50) was selected as the support electrolyte due to obtaining the highest electronic signal increase during oxidation of NAP at UTGE. The differential pulse voltammetry (DPV) technique was performed for electrochemical determination of NAP. In the optimum conditions, the limits of detection (LOD) and quantification (LOQ) were determined to be 8.6610-8 M and 2.8810-7 M. In addition, the amount of NAP was determined in drug tablets. The recovery studies of NAP from the drug tablet were completed in order to check the accuracy and precision of the applied voltammetric method. Furthermore, the determination of NAP was performed with the high-performance liquid chromatography (HPLC) method. These two methods were compared in terms of accuracy, precision and recovery studies.

🔖

Cite This Article

YANIK, S. Y., YILMAZ, S., SAGLIKOGLU, G., SADIKOGLU, M., YAYINTAS, Ö. T. (2019). VOLTAMMETRIC AND CHROMATOGRAPHIC DETERMINATION OF NAPROXEN IN DRUG FORMULATION. Health Sciences Quarterly, Cilt: 3 - Sayı: 4, 299–310. https://ajindex.com/articles/836614

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. BOYNTON C.S., DICK C.F., MAYOR G.H., 1988, NSAID: An overview, J. Clint. Pharmacology, 28: 512 [2] KAYNAK M.S., ŞAHİN S.A., 2008, A new hplc approach for determination of in-vitro solubility of naproxen sodium, J, Hacettepe Univ. J. The Faculty of Pharm. 28, 49 [3] ARESTA A., PALMISANO F., ZAMBONIN C.G., 2005, Determination of naproxen in human urine by solid-phase microextraction coupled to liquid chromatography,J. Pharm. Biomed. Anal. 39, 643 [4] JAIN N.A., LOHIYA R.T., UMEKAR M.J., 2011, Spectrophotometric determination of naproxen and esomerprazole in a laboratory mixture by simultaneous equation, absorption correction, absorption ratio and area under curve methods, Int. J. Pharma Sci. and Research. 2, 130 (ISSN: 0975-9492) [5] YILMAZ B., ASCI A., ERDEM A.F., 2014, HPLC method for naproxen determination in human plasma and its application to a pharmacokinetic Study in Turkey J. Chromatogr. Sci. 52, 584 [6] TSVETKOVA B., 2015, RP-HPLC method for determination of naproxen in pharmaceutical dosage form, Pharmacia. 62, 15 [7] UYSAL Ü.D., TUNCEL M., 2004, Determination of naproxen in tablets by using first derivative potentiometry, Turkish J. Pharm. Sci. 1, 217 [8] DAMIANI P., BEARZOTTI M., CABEZÓN M.A., 2002, Spectrofluorometric determination of naproxen in tablets, J. Pharm. Biomed. Anal. 29, 229 [9] SARHANGZADEH K., 2015, Application of multi wall carbon nanotube–graphene hybrid for voltammetric determination of naproxen, J. Iran Chem. Soc. 12, 2133 [10] STEFANO J.S., LIMA A.P., MONTES R.H.O., RICHTER E.M., MUÑOZ R.A.A., 2012, Fast determination of naproxen in pharmaceutical formulations by batch injection analysis with pulsed amperometric detection, Braz. Chem. Soc. 23, 1834 [11] SOLTANI N., TAVAKKOLI N., MOSAVIMANESH Z.S., DAVAR F., 2018, Electrochemical determination of naproxen in the presence of acetaminophen using a carbon paste electrode modified with activated carbon nanoparticles,C.R. Chimie, 21, 54 [12] ADHOUM N., MONSER L., TOUMI M., BOUJLEL K., 2003, Determination of naproxen in pharmaceuticals by differential pulse voltammetry at a platinum electrode, Anal. Chim. Acta, 495, 69 [13] SURYANARAYANAN V., ZHANG, YOSHIHARA Y. S., SHIRAKASHI T., 2005, Voltammetric assay of naproxen in pharmaceutical formulations using boron-doped diamond electrode, Electroanalysis, 17, 925 [14] TASHKHOURIAN J., HEMMATEENEJAD B., BEIGIZADEH H., HOSSEINI-SARVARI M., RAZMI Z., 2014, ZnO nanoparticles and multiwalled carbon nanotubes modified carbon paste electrod