Journals / Health Sciences Quarterly / 2020 / Cilt: 4 - Sayı: 1

ELECTROCHEMICAL BIOSENSOR FOR BRCA1 GENE AND TAMOXIFEN INTERACTION

Pages
35–48
Publication Date
2020-01-31
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Additionally, it was found that TAM interact with guanine bases and TAM signal which is near the guanine oxidation area also increase after the interaction with DNA.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The electrochemical nanobiosensor was designed for the determination of specific DNA sequences related to breast cancer 1 (BRCA1) gene and interaction between Anticancer Drug Tamoxifen (TAM) and related DNA sequences by using pencil graphite electrode (PGE), bare and multi-walled carbon nanotube (MWCNT) contained screen printed carbon electrodes (SPEs) for the first time.
📊
Key Findings & Data:It was obtained that the guanine signal at about +1.00V obtained from probe DNA or hybrid DNA shows a remerkable increase after the interaction with TAM.
💡
Conclusion & Impact:Additionally, it was found that TAM interact with guanine bases and TAM signal which is near the guanine oxidation area also increase after the interaction with DNA.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Tamoxifen · BRCA1 · Electrochemical DNA nanobiosensor

Abstract

The electrochemical nanobiosensor was designed for the determination of specific DNA sequences related to breast cancer 1 (BRCA1) gene and interaction between Anticancer Drug Tamoxifen (TAM) and related DNA sequences by using pencil graphite electrode (PGE), bare and multi-walled carbon nanotube (MWCNT) contained screen printed carbon electrodes (SPEs) for the first time. Here, biomolecular interaction between TAM and DNA was investigated differential pulse voltammetry (DPV) based on not only guanine signal but also TAM oxidation response. It was obtained that the guanine signal at about +1.00V obtained from probe DNA or hybrid DNA shows a remerkable increase after the interaction with TAM. Additionally, it was found that TAM interact with guanine bases and TAM signal which is near the guanine oxidation area also increase after the interaction with DNA. Consequently, the prepared biosensor offer suitable platform for the analysis of DNA hybridization and TAM-DNA interaction sensitively.

Özet

The electrochemical nanobiosensor was designed for the determination of specific DNA sequences related to breast cancer 1 (BRCA1) gene and interaction between Anticancer Drug Tamoxifen (TAM) and related DNA sequences by using pencil graphite electrode (PGE), bare and multi-walled carbon nanotube (MWCNT) contained screen printed carbon electrodes (SPEs) for the first time. Here, biomolecular interaction between TAM and DNA was investigated differential pulse voltammetry (DPV) based on not only guanine signal but also TAM oxidation response. It was obtained that the guanine signal at about +1.00V obtained from probe DNA or hybrid DNA shows a remerkable increase after the interaction with TAM. Additionally, it was found that TAM interact with guanine bases and TAM signal which is near the guanine oxidation area also increase after the interaction with DNA. Consequently, the prepared biosensor offer suitable platform for the analysis of DNA hybridization and TAM-DNA interaction sensitively.

🔖

Cite This Article

YANIK, S., OZKAN-ARIKSOYSAL, D., YILMAZ, S. (2020). ELECTROCHEMICAL BIOSENSOR FOR BRCA1 GENE AND TAMOXIFEN INTERACTION. Health Sciences Quarterly, Cilt: 4 - Sayı: 1, 35–48. https://ajindex.com/articles/836610

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (16)

  1. BAGNI, G, MASCINI, M., 2010. DNA Biosensor for Environmental Risk Assessment and Drugs Studies. In: Sensors for Chemical and Biological Applications. Ed.: Ram, M. K., Bhethanabotla, V. R., Boca Raton, FL: CRC Press. 249–276.
  2. DANESHGAR, P., NOROUZI, P., GANJALI, M. R., ZAMANI, H. A. 2009. Ultrasensitive flow-injection electrochemical method for detection of anticancer drug tamoxifen, Talanta, 77: 1075-1080.
  3. HURTADO-MONROY, R., VARGAS-VIVEROS, P., CARRILLO-MUÑNOZ, S., DUENAS-GONZALEZ, A., 2007. Tamoxifen-associated vasculitis in a breast cancer patient, World Journal of Surgical Oncology, 5-7
  4. KATZ, E., WILLNER, I., WANG, J., 2004. Electroanalytical and Bioelectroanalytical Systems Based on Metal and Semiconductor Nanoparticles, Electroanal., 16: 19-44.
  5. KEİSHAM, R., PROBHAT, K., RAJU K., 2012. Detection of anticancer drug tamoxifen using biosensor based on polyaniline probe modified with horseradish peroxidase, Materials Science and Engineering C,33: 583-587.
  6. KELSEY, J. L., BERNSTEIN, L., 1996. Epidemiology and Prevention of Breast Cancer, Annual Review of Public Health, 17:47-67.
  7. OZKAN, D., KARADENIZ H., ERDEM A., MASCINI M., OZSOZ M., 2004. Electrochemical genosensor for Mitomycin C- DNA interaction based on guanine signal, Journal of Pharmaceutical and Biomedical Analysis, 35(4), 905-912
  8. PATOLSKY, F., LIEBER, C.M., 2005.
  9. Nanowire nanosensors, Materials Today, 8(4): 20-28.
  10. PUMERA, M., SANCHEZ, S., ICHINOSE, I., TANG, J., 2007.
  11. Electrochemical nanobiosensors, Sensors and Actuators B Chem., 123: 1195-1205.
  12. SEYMA AYDINLIK, S., OZKAN-ARIKSOYSAL, D., KARA, P., SAYINER, A. A., OZSOZ, M., 2011. A nucleic acid-based electrochemical biosensor for the detection of influenza B virus from PCR samples using gold nanoparticle-adsorbed disposable graphite electrode and Meldola’s blue as an intercalator, Anal. Methods, 3, 1607–1614.
  13. SUBAK, H., OZKAN-ARIKSOYSAL, D., 2018. Label-Free electrochemical biosensor for the detection of ınfluenza genes and the solution of guanine-based displaying problem of dna hybridization. Sens. Actuators B, 263, pp. 196-207
  14. TOPKAYA, S. N., OZKAN-ARIKSOYSAL, D., 2016. Prostate cancer biomarker detection with carbon nanotubes modified screen printed electrodes, Electroanalysis, 28(5), 1077-1084.
  15. WANG, J., 2005. Nanomaterial-based electrochemical biosensors, Analyst, 130: 421-426.
  16. YARMAN, A., and SCHELLER. F. W., 2014. The first electrochemical mıp sensor for tamoxifen, Sensors,14, 7647-7654.