Journals / Turkish Journal of Analytical Chemistry / 2019 / Cilt: 1 - Sayı: 1

Schiff bases carrying dipicolylamine groups for selective determination of metal ions in aqueous media. A phenanthrene-based fluorescent sensor for Hg2+ determination

Pages
1–1
Publication Date
2019-12-11
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Detection and quantification limits were 0.009 mg L-1 and 0.027 mg L-1, respectively.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Abstract: Four new dipicolylamine compounds carrying anthracene, naphthalene, pyrene and phenanthrene groups were synthesized, and their ion sensor properties were studied by means of emission spectrometry in ethanol-water (1:1).
📊
Key Findings & Data:It was disclosed that among a series of studied anions and cations, only with Cd2+, Zn2+, Cu2+ and Hg2+ cations, ligands formed complexes selectively.
💡
Conclusion & Impact:Detection and quantification limits were 0.009 mg L-1 and 0.027 mg L-1, respectively.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Ion sensor · Hg2+ determination · Dipicolylamine

Abstract

Abstract: Four new dipicolylamine compounds carrying anthracene, naphthalene, pyrene and phenanthrene groups were synthesized, and their ion sensor properties were studied by means of emission spectrometry in ethanol-water (1:1). It was disclosed that among a series of studied anions and cations, only with Cd2+, Zn2+, Cu2+ and Hg2+ cations, ligands formed complexes selectively. With spectrofluorimetric measurements, the complexation stoichiometry and the complex stability constants of the formed complexes were determined. A linear range from 0.10 µg L-1 to0.15 mg L-1 where the fluorescence intensity of the phenanthrene derivative compound showed a regular decrease with the increase of the Hg2+ ion concentration was obtained. The method developed for the determination of Hg2+ was applied to tap water samples. In order to eliminate the matrix effect, a modified standard addition method was used. Detection and quantification limits were 0.009 mg L-1 and 0.027 mg L-1, respectively.

🔖

Cite This Article

GÜMRÜKÇÜOĞLU, A., ÖZBEK, N., AK, T., VANLI, E., OCAK, M., OCAK, Ü. (2019). Schiff bases carrying dipicolylamine groups for selective determination of metal ions in aqueous media. A phenanthrene-based fluorescent sensor for Hg2+ determination. Turkish Journal of Analytical Chemistry, Cilt: 1 - Sayı: 1, 1–1. https://ajindex.com/articles/808296

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. L.M. Plum, L. Rink, H. Hajo. Int. J. Environ. The Essential Toxin: Impact of Zinc on Human Health. Res. Public Health.2010;7(4):1342-1365 2. B. Fernandes Azevedo, L. Barros Furieri, F.M. Peçanha, G.A. Wiggers, P. Frizera Vassallo, M. Ronacher Simões, J. Fiorim, P. Rossi de Batista, M. Fioresi, L. Rossoni. Toxic Effects of Mercury on the Cardiovascular and Central Nervous Systems.J. Biomed. Biotechnol. 2012. DOI: 10.1155/2012/949048. 3. H. Refiker, M. Merdivan, R.S. Aygun. Selective Preconcentration of Gold from Ore Samples. Int. J. Anal. Chem., 2018, 7503202. 4. M.R. Ganjali, L.H Babaei, A. Badiei, K. Saberian, S. Behbahani, G. M. Ziarani, M. Salavati- Niasari.A novel method for fast enrichment and monitoring of hexavalent and trivalent chromium at the ppt level with modified silica MCM-41 and its determination by inductively coupled plasma optical emission spectrometry. Química Nova.2006;29(3):440-443. 5. K. Pyrzynska, T. Wierzbicki. Solid-Phase Extraction for Preconcentration and Separation of Vanadium Species in Natural Waters. Microchim Acta. 2004;147(1-2):59-64. 6. I.L. Alcantara, P.S. Roldan, G.R Castro, F.V. Moraes, F.A. Silva, C.C. Padilha, J.D. Oliveira, P.M. Padilha. Determination of Cadmium in River Water Samples by Flame AAS after On-line Preconcentration in Mini-Column Packed with 2-Aminothiazole-modified Silica Gel. Anal. Sci. 2004; 20(7):1029-1032. 7. V.A. Lemos, L.O. Dos Santos. A new method for preconcentration and determination of mercury in fish, shellfish and saliva by cold vapour atomic absorption spectrometry. Food Chem. 2014;149: 203-207. 8. M. Ali. Preconcentration and Determination of Trace Amounts of Heavy Metals in Water Samples Using Membrane Disk and Flame Atomic Absorption Spectrometry. Chinese J. Chem., 2007;25(5): 640-644. 9. N. Altunay, R. Gürkan. A simple and efficient approach for preconcentration of some heavy metals in cosmetic products before their determinations by flame atomic absorption spectrometry. Turk. J. Chem. 2016, 40: 988–1001. 10. B. Valeur, I. Leray. Design principles of fluorescent molecular sensors for cation recognition. Coord. Chem. Rev. 2000; 205(1):3-40. 11. L.G. Pathberiya, N. Barlow, T. Nguyen, B. Graham, K.L. Tuck. Facile, divergent route to bis-Zn(II)dipicolylamine type chemosensors for pyrophosphate. Tetrahedron. 2012;68(46): 9435-9439. 12. J.H. Kim, J.Y. Noh, I.H. Hwang, J. Kang, J. Kim, C. Kim. An anthracene-based fluorescent chemosensor for Zn2+ Tetrahedron Lett. 2013;54(19): 2415-2418. 13.