Journals / Natural and Engineering Sciences / 2017 / Cilt: 2 - Sayı: 3

Poly(N-Methylpyrrole)-Chitosan layers for Glucose Oxidase Immobilization for Amperometric Glucose Biosensor Design

Pages
123–134
Publication Date
2017-11-11
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

After 20 successive uses of same enzyme electrode in 5 mM glucose solution, it was still its 91.3 % of initial activity.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, Pt electrode was coated by poly(N-methypyrrol) (PNMP) film, then Glucose Oxidase (GOD) was immobilized onto PNMP layer with thin chitosan (Chi) gel, and finally, the electrode was reacted with glutaraldehyde (GAL) to form crosslinking between –NH2 groups of Chi and GOD to prevent enzyme leakage from Chi.
📊
Key Findings & Data:The preparation of electrode conditions have significant effect on current values which were measured and optimized in presence of glucose, polymer synthesis and GOD immobilization conditions.
💡
Conclusion & Impact:After 20 successive uses of same enzyme electrode in 5 mM glucose solution, it was still its 91.3 % of initial activity.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Glucose · poly(N-methylpyrrole) · amperometric biosensor

Abstract

In this study, Pt electrode was coated by poly(N-methypyrrol) (PNMP) film, then Glucose Oxidase (GOD) was immobilized onto PNMP layer with thin chitosan (Chi) gel, and finally, the electrode was reacted with glutaraldehyde (GAL) to form crosslinking between –NH2 groups of Chi and GOD to prevent enzyme leakage from Chi. GOD-based electrode was used to measure current response depending on glucose concentration by chronoamperometric method. The preparation of electrode conditions have significant effect on current values which were measured and optimized in presence of glucose, polymer synthesis and GOD immobilization conditions. Therefore, the effect of N-methylpyrrole monomer concentration, scan rate, Chi concentration, GOD concentration and GAL concentration on biosensor response were investigated by classical method. In sight of obtained data, optimal monomer concentration and scan rates for PNMP synthesis were determined as 50 mM and 20 mV/s, respectively. Optimal Chi, GOD and GAL concentrations were found as 1,00%, 4 mg/mL and 0.025 %, respectively. SEM images of Pt, PNMP coated Pt and GOD immobilized Pt electrodes were obtained. After 20 successive uses of same enzyme electrode in 5 mM glucose solution, it was still its 91.3 % of initial activity.

🔖

Cite This Article

Ozyilmaz, G., Özyılmaz, A. T., Akyürekoğlu, R. H. (2017). Poly(N-Methylpyrrole)-Chitosan layers for Glucose Oxidase Immobilization for Amperometric Glucose Biosensor Design. Natural and Engineering Sciences, Cilt: 2 - Sayı: 3, 123–134. https://ajindex.com/articles/793265

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Abasiyanik, M. F & Senel, M. (2010). Immobilization of glucose oxidase on reagentless ferrocene-containing polythiophene derivative and its glucose sensing application, Journal of Electroanalytical Chemistry, 639, 21–26
  2. Abu-Rabeah, K., Niţǎ, I.I., Tencaliec, A.M., Marks, R.S. (2009). New approach of constructing biosensing matrices by physical and chemical crosslinking of biotin-alginate with alginate-pyrrole, Electrochimica Acta, 54, 4359-4364
  3. Arslan F., Ustabaş S., Arslan H. (2011). An Amperometric Biosensor for Glucose Determination Prepared from Glucose Oxidase Immobilized in Polyaniline-Polyvinylsulfonate Film. Sensors, 11, 8152-8163
  4. Borole D. D., Kapadi U. R., Mahulikar P. P., Hundiwale, D. G. (2007). Glucose oxidase electrodes of polyaniline, poly(o-anisidine) their co-polymer as a biosensor: a comparative study, Journal of Material Science, 42,4947–4953
  5. Deng, H., Teo, A.K.L., Gao, Z. (2014). An interference-free glucose biosensor based on a novel low potentialredox polymer mediator. Sensors and Actuators B, 191, 522– 528 Eftekhari, A. (2004). Electropolymerization of aniline onto passivated substrate and its application for preparation of enzyme-modified electrode, Synthetic Metals, 145, 211-216
  6. Ekiz, F., Oğuzkaya F., Akin M., Tanyeli C., Toppare L. (2011). Synthesis and application of poly-SNS-anchored carboxylic acid: a novel functional matrix for biomolecule conjugation, Journal of Materials Chemistry, 21, 12337-12343
  7. Guadalupe de Jesus, C., Lima, D., Santos, V., Wohnrath, K., Pessoa, C.A. (2013), Glucose biosensor based on the highly efficient immobilization of glucose oxidase on layer-by-layer films of silsesquioxane polyelectrolyte, Sensors and Actuators B, 186, 44-51
  8. Haighi, B., Nazari, L., Sajjadi, S.M., (2012). Fabrication and application of a sensitive and highly stable copper hexacyanoferrate modified carbon ionic liquid paste electrode for hydrogen peroxide and glucose detection, Electroanalysis, 24, 2165-2175.
  9. Huang, Y., Qin X., Li Z., Fu, Y., Qin C., Wu, F., Su, Z., Ma, M., Xie, Q., Yao, S.H., Hu, J. (2012). Fabrication of a chitosan/glucose oxidase–poly(anilineboronic acid)–Aunano/Au-plated Au electrode for biosensor and biofuel cell. Biosensors and Bioelectronics, 31, 357-362
  10. Jiang, Y., Zhang, Q., Li, F., Niu, L. (2012). Glucose oxidase and graphene bionanocomposite bridged by ionic liquid unit for glucose biosensing application, Sensors and Actuators B, 161, 728-733
  11. Kadam, S.B., Datta K., Ghosh P. & Shirsat, M.D (2011). Poly(Pyrrol