Journals / Journal of Surgery and Medicine / 2021 / Cilt: 5 - Sayı: 1

Retrospective analysis of the use of 22-gauge and 25-gauge needles for EUS-guided fine needle aspiration of solid lesions

Pages
22–25
Publication Date
2021-01-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The use of 25G needles in hard masses can provide ease of puncture.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Background/Aim: Data on the comparison of diagnostic yields of 22-gauge (22G) and 25-gauge (25G) needles used in endoscopic ultrasound guided fine needle aspiration (EUS-FNA) biopsy usually include solid pancreatic masses.
📊
Key Findings & Data:In our study, we compared the diagnostic yield, safety, and performance characteristics of 22G and 25G needles in the EUS-FNA of various solid lesions in or adjacent to the upper gastrointestinal wall and suspicious lymph nodes.
💡
Conclusion & Impact:The use of 25G needles in hard masses can provide ease of puncture.
🔬Design:Research Article
📍Scope:2018 Verileri
⚙️Variables:EUS-FNA · cytopathology · 22-gauge needle

Abstract

Background/Aim: Data on the comparison of diagnostic yields of 22-gauge (22G) and 25-gauge (25G) needles used in endoscopic ultrasound guided fine needle aspiration (EUS-FNA) biopsy usually include solid pancreatic masses. In our study, we compared the diagnostic yield, safety, and performance characteristics of 22G and 25G needles in the EUS-FNA of various solid lesions in or adjacent to the upper gastrointestinal wall and suspicious lymph nodes. Methods: In this retrospective cohort study, we enrolled patients who underwent EUS-FNA using 22G and 25G needles between August 2018 and January 2020. We compared EUS-FNA results with histological findings in operated patients and long-term clinical follow-up results in non-operated patients. Results: Seventy-nine patients (40 patients with 22G needles) were enrolled. There were pancreatic solid masses in 50 (63.3%) patients, subepithelial lesions in 13 (16.5%), suspicious lymph nodes in 12 (15.2%), and various lesions adjacent to the lumen in 4 (5.1%) patients. The diagnostic yield of 22G and 25G needles were 92.5% and 94.9%, respectively, which were similar (P=0.664). EUS-FNA of 2 pancreatic masses required a crossover from a 22G needle to a 25G needle due to lesion stiffness. The technical success rate for the lesion type was 100% and 95% for 25G and 22G needles, respectively (P=0.160). No major complications were observed with either needle. Conclusions: The 25G needle was not superior to the 22G needle in terms of diagnostic yield and safety profile in EUS-FNA of solid lesions. The use of 25G needles in hard masses can provide ease of puncture.

🔖

Cite This Article

KOC, D. O., GÖKDEN, Y. (2021). Retrospective analysis of the use of 22-gauge and 25-gauge needles for EUS-guided fine needle aspiration of solid lesions. Journal of Surgery and Medicine, Cilt: 5 - Sayı: 1, 22–25. https://ajindex.com/articles/780098

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (10)

  1. Yamao K, Sawaki A, Mizuno N, Shimizu Y, Yatabe Y, Koshikawa T. Endoscopic ultrasound-guided fine-needle aspiration biopsy (EUS-FNAB): past, present, and future. J Gastroenterol. 2005
  2. 40(11):1013-23. doi: 10.1007/s00535-005-1717-6 2. Camellini L, Carlinfante G, Azzolini F, Iori V, Cavina M, Sereni G, et al. A randomized clinical trial comparing 22G and 25G needles in endoscopic ultrasound-guided fine-needle aspiration of solid lesions. Endoscopy. 2011
  3. 43(8):709-15. doi: 10.1055/s-0030-1256482. 3. Fabbri C, Polifemo AM, Luigiano C, Cennamo V, Baccarini P, Collina G, et al. Endoscopic ultrasound-guided fine needle aspiration with 22- and 25-gauge needles in solid pancreatic masses: a prospective comparative study with randomisation of needle sequence. Dig Liver Dis. 2011
  4. 43(8):647-52. doi: 10.1016/j.dld.2011.04.005. 4. Vilmann P, SĂftoiu A, Hollerbach S, Guldhammer Skov B, Linnemann D, Popescu CF, et al. Multicenter randomized controlled trial comparing the performance of 22 gauge versus 25gauge EUS-FNA needles in solid masses. Scand J Gastroenterol. 2013
  5. 48(7):877-83. doi: 10.3109/00365521.2013.799222. 5. Affi A, Vazquez-Sequeiros E, Norton ID, Clain JE, Wiersema MJ. Acute extraluminal hemorrhage associated with EUS-guided fine needle aspiration: frequency and clinical significance. Gastrointest Endosc. 2001
  6. 53(2):221-25. doi: 10.1067/mge.2001.111391. 6. Affolter KE, Schmidt RL, Matynia AP, Adler DG, Factor RE. Needle size has only a limited effect on outcomes in EUS-guided fine needle aspiration: a systematic review and meta-analysis. Dig Dis Sci. 2013
  7. 58(4):1026-34. doi: 10.1007/s10620-012-2439-2. 7. Guedes HG, Hourneaux de Moura DT, Duarte RB, Coronel Cordero MA, Lera Dos Santos ME, Cheng S, et al. A comparison of the efficiency of 22G versus 25G needles in EUS-FNA for solid pancreatic mass assessment: A systematic review and meta-analysis. Clinics. 2018
  8. e261. doi: 10.6061/clinics/2018/e261. 8. Alper E, Onur I, Arabul M, Unsal B. Endoscopic ultrasound-guided tissue sampling: How can we improve the results? Turk J Gastroenterol. 2016
  9. 27(1):1-3. doi: 10.5152/tjg.2015.150497. 9. Siddique DA, Rahal MA, Trevino K, Wu HH, Al-Haddad MA. Endoscopic ultrasound-guided sampling of solid pancreatic lesions: A comparative analysis of 25 gauge versus 22 gauge core biopsy needles. Anticancer Res. 2020
  10. 40(10):5845-51. doi: 10.21873/anticanres.14603. 10. Lee JK, Lee KT, Choi ER, Jang TH, Jang KT, Lee JK, et al. A prospective, randomized trial comparing 25-gauge and