⚡ TL;DR(Too Long; Didn't Read)

Overall heat transfer coefficient (U-value) of RMB is determined to be 0.916 W/m2.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Heat loss/gain through the walls accounts for about 30% of the total building energy losses.
📊
Key Findings & Data:A reliable CFD software ANSYS FLUENT 18.1 is utilised in the research.
💡
Conclusion & Impact:Overall heat transfer coefficient (U-value) of RMB is determined to be 0.916 W/m2.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Hollow bricks · Lightweight concrete · Numerical simulation

Abstract

Heat loss/gain through the walls accounts for about 30% of the total building energy losses. Bricks are indispensable parts of buildings as a very common masonry wall unit; hence the present work aims at optimising thermal resistance of lightweight concrete hollow bricks through a CFD based numerical research. The optimisation is conducted over a certain number of independent variables such as hollow geometry and design, number of hollow rows across the heat transfer path and hollow depth for natural convection aspects within the hollow enclosure. A reliable CFD software ANSYS FLUENT 18.1 is utilised in the research. The accuracy of the CFD results is justified first through the reference model brick (RMB). Overall heat transfer coefficient (U-value) of RMB is determined to be 0.916 W/m2. K, which is in good accordance with the manufacturer’s data report (0.9 W/m2.K). Following this, parametric research is carried out for various scenarios to optimise the U-value as a function of brick mass. Based on the findings, the maximum improvement is found to be about 53% (U-value 0.43 W/m2. K) through the case of B48 which has an h-ratio of 1 (continuous hollow from top to bottom). Moreover, depending on the increase in h-ratio, it is achieved that the thermal performance of the bricks proportionally increases. The minimum weight of the brick design (B45) is found to be 7.645 kg and the corresponding U-value is obtained as 0.44 W/m2. K.

🔖

Cite This Article

CUCE, E., CUCE, P. M., BESİR, A. B. (2020). Improving thermal resistance of lightweight concrete hollow bricks: A numerical optimisation research for a typical masonry unit. Journal of Energy Systems, Cilt: 4 - Sayı: 3, 121–144. https://ajindex.com/articles/776268

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Besir, AB, Cuce, E. Green roofs and facades: A comprehensive review. Renewable and Sustainable Energy Reviews 2018; 82(1): 915-939
  2. Martínez, MA, Tort, AI, Cho, S, Vivancos, JL. Energy efficiency and thermal comfort in historic buildings: A review. Renewable and Sustainable Energy Reviews 2016; 61: 70-85
  3. IEA. Tracking Buildings https://www.iea.org/reports/tracking-buildings; 2019 [accessed May 14, 2020]
  4. Raji, B, Tenpierik, MJ, Van Den Dobbelsteen, A. An assessment of energy-saving solutions for the envelope design of high-rise buildings in temperate climates: A case study in the Netherlands. Energy Buildings 2016; 124: 201-221
  5. Guo, Q, Wu Y, Ding, Y, Feng, W, Zhu, N. Measures to enforce mandatory civil building energy efficiency codes in China. Journal of Cleaner Production 2016; 119: 152-166
  6. Peuportier, B, Thiers, S, Guiavarch, A. Eco-design of buildings using thermal simulation and life cycle assessment. Journal of Cleaner Production 2013; 39: 73-8
  7. De Boeck, L, Verbeke, S, Audenaert, A, De Mesmaeker, L. Improving the energy performance of residential buildings: A literature review. Renewable and Sustainable Energy Reviews 2015; 52: 960-975
  8. Kampelis, N, Gobakis, K, Vagias, V, Kolokotsa, D, Standardi, L, Isidori D, et al. Evaluation of the performance gap in industrial, residential & tertiary near-Zero energy buildings. Energy and Buildings 2017; 148: 58-73
  9. Cuce, E, Cuce, PM, Wood, CJ, Riffat, SB. Optimizing insulation thickness and analysing environmental impacts of aerogel-based thermal superinsulation in buildings. Energy and Buildings 2014; 77: 28-39
  10. Cuce, E, Riffat, SB. Aerogel-assisted support pillars for thermal performance enhancement of vacuum glazing: A CFD research for a commercial product. Arabian Journal for Science and Engineering 2015; 40(8): 2233-2238
  11. Cuce, E, Cuce, PM, Young, CH. Energy saving potential of heat insulation solar glass: Key results from laboratory and in-situ testing. Energy 2016; 97: 369-380
  12. Cuce, E, Riffat, SB. Vacuum tube window technology for highly insulating building fabric: An experimental and numerical investigation. Vacuum 2015; 111: 83-91
  13. Cuce, E, Cuce, PM. The impact of internal aerogel retrofitting on the thermal bridges of residential buildings: An experimental and statistical research. Energy and Buildings 2016; 116: 449-454
  14. Cuce, E. Toward multi-functional PV glazing technologies in low/zero carbon buildings: Heat insulation solar glass -