Journals / Eastern Anatolian Journal of Science / 2017 / Cilt: 3 - Sayı: 2

CHEMOMETRIC ANALYSIS OF MOXIFLOXACIN AND METRONIDAZOLE IN BINARY DRUG COMBINATIONS WITH SPECTROPHOTOMETRIC METHOD

Pages
30–37
Publication Date
2017-11-30
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The second step, in drug tablets (Avelox and Flagy), was calculated amounts for metronidazole and moxifloxacin.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, sensitive and accurate spectrophotometric-chemometric methods were developed for metronidazole and moxifloxacin without any separation step in pharmaceutical tablets.
📊
Key Findings & Data:A concentration set including binary mixtures of metronidazole and moxifloxacin formed to 24 different combinations were randomly prepared in 0.1 M HCl.
💡
Conclusion & Impact:The second step, in drug tablets (Avelox and Flagy), was calculated amounts for metronidazole and moxifloxacin.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Metronidazole and moxifloxacin · PLS

Abstract

In this study, sensitive and accurate spectrophotometric-chemometric methods were developed for metronidazole and moxifloxacin without any separation step in pharmaceutical tablets. The examined Alzheimer's drugs are donepezil and rivastigmine. The used chemometric methods are partial least squares regression (PLS) and principal component regression (PCR). PLS and PCR were successfully applied for chemometric analysis of metronidazole and moxifloxacin in synthetic mixtures and pharmaceutical tablets. A concentration set including binary mixtures of metronidazole and moxifloxacin formed to 24 different combinations were randomly prepared in 0.1 M HCl. The accuracy and precision of the developed method were validated by analyzing synthetic mixtures containing the examined drugs. As a result of the determination, high recoveries and low standard deviations were found. Absorbance and concentration values were used in Minitab and other chemometric programs to calculate estimated concentrations with PCR and PLS. The second step, in drug tablets (Avelox and Flagy), was calculated amounts for metronidazole and moxifloxacin.

🔖

Cite This Article

Ertokuş, G. P., ÇELİK, Ü. M. (2017). CHEMOMETRIC ANALYSIS OF MOXIFLOXACIN AND METRONIDAZOLE IN BINARY DRUG COMBINATIONS WITH SPECTROPHOTOMETRIC METHOD. Eastern Anatolian Journal of Science, Cilt: 3 - Sayı: 2, 30–37. https://ajindex.com/articles/751617

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. ELKADY, E.F., MAHROUSE, M.A., (2011), Reversed-phase ion-pair HPLC and TLC-densitometric methods for the simultaneous determination of ciprofloxacin hyrochloride and metronidazole in tablets, Chromatographia, (73), 297-305
  2. TRAIRATVORAKUL, C., DETSOMBOONRAT, P., (2011), Success rates of a mixtures of ciprofloxacin, metronidazole and minocycline antibiotics used in the non-instrumentation endodontic treatment of mandibular primary molars with carious pulpal involvement, International Journal Of Paediatric Dentistry, 1-11
  3. JAIN, R., JAIN, N., JAIN, D.K., PATEL, V.K., RAJAK, H., JAIN, S.K., (2017), Novel UV spectrophotometer methods for quantitative estimation of metronidazole and furazolidone using mixed hydrotropy solubilization, Arabian Journal Of Chemistry, (10), 151-156
  4. MAHROUSE, M.A., ELKADY, E.F., (2011), Validated spectrophotometric methods for the simultaneous determination of ciprofloxacin hydrochloride and metronidazole in tablets, Chem.Pharm.Bull., 59(12), 1485-1493
  5. SAHOO, D.R., JAIN, S., (2016), A rapid and validated RP-HPLC method for the simultaneous quantificiation of benzoic acid, metronidazole and miconazole nitrate in vaginal formulations, Journal Of Chromatographic Sciences, 54(9), 1613-1618
  6. MORCOSS, M.M., ABDELWAHAB, N.S., ALI, N.W., ELSAADY, M.T., (2016), Different chromatographic methods for simultaneous determination of diloxanide furoate, metronidazole and its toxic impurity, J.IRAN CHEM SOC, (13), 1643-1651
  7. HERNANDEZ-JIMENEZ, A., ROA-MORALES, G., REYES-PEREZ, H., BALDERAS-HERNANDEZ, P., BARRERA-DIAZ, C.E., BERNABE-PINEDA, M., (2016), Voltammetric determination of metronidazole using a sensor based on electropolymerization of α-Cyclodextrin over a carbon paste electrode, Electoanalysis, (28), 704-710
  8. SAGHRAVANIAN, M., EBRAHIMI, M., ES’HAGHI, Z., BEYRAMABADI, S.A., (2017), Experimental sensing and density functional theory study of an ionic liquid mediated carbon nanotube modified carbon-paste electrode for electrochemical detection of metronidazole, South African Journal of Chemistry,(70), 29-37
  9. SULTAN, M.A., (2009), New, simple and validated kinetics spectrophotometric method for determination of moxifloxacine in its pharmaceutical formulations, Arabian Journal Of Chemistry, (2), 79-85
  10. AL OMARI, M.M.H., JAAFARI, D.S., AL-SOUOD, K.A., BADWAN, A.A., (2014), Moxifloxacin Hydrochloride, Profiles of Drug Substances. Excipients and Related Methodology, (39), 299-420
  11. ASHOUR, S., BAYRAM, R., (2015),