⚡ TL;DR(Too Long; Didn't Read)

Conclusion: As a result, block success and patient satisfaction was found similar in ultrasound-guided neurostimulator and only neurostimular used axillary brachial plexus block; complication rate observed was significantly low in in ultrasound-guided neurostimulator group.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objectives: Different methods may be used in application of axillar block.
📊
Key Findings & Data:Methods: After obtaining approval from the ethics committee and consent of the patients, 50 ASA I III patients over age of 20 waiting for forearm and hand surgery have been included in this study.
💡
Conclusion & Impact:Conclusion: As a result, block success and patient satisfaction was found similar in ultrasound-guided neurostimulator and only neurostimular used axillary brachial plexus block; complication rate observed was significantly low in in ultrasound-guided neurostimulator group.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:ULTRASONOGRAPHY · AXILLER BLOCK · nerustimulator

Abstract

Objectives: Different methods may be used in application of axillar block. The aim of this study is to investigate the effect of ultrasonography on block success, complications and patient satisfaction in application of Axillary Brachial Plexus Block. Methods: After obtaining approval from the ethics committee and consent of the patients, 50 ASA I III patients over age of 20 waiting for forearm and hand surgery have been included in this study. Pulse, non invasive blood pressure and peripheral oxygen saturation of the patients were monitored after their demographic data were recorded. Brachial plexus block was applied with only neurostimulator in Group I (n=25) and with ultrasonography guided neurostimulator in Group II (n=25). Number of skin punctures, presence of vascular punctures and processing time was recorded. Sensorial block formation was evaluated by pin prick testing, motor block was evaluated by Holmenn scale, and sensation of pain was evaluated with numerical pain rating scale. Operation began after duration of block formations were recorded. Need for general anesthesia and patient satisfaction was also recorded. Results: Demographic data, time of onset of motor and sensorial block, operation and process time, and pain score was found to be similar in Group I and II. Number of skin punctures and vascular punctures were significantly less in Group II. Conclusion: As a result, block success and patient satisfaction was found similar in ultrasound-guided neurostimulator and only neurostimular used axillary brachial plexus block; complication rate observed was significantly low in in ultrasound-guided neurostimulator group.

🔖

Cite This Article

GÖK, E., TÜRKMEN, Ü. A., MORALAR, D. G., ERVATAN, Z., DENİZLİ, E., ÇAKIRGÖZ, M. (2021). Comparison Neurostimulator Use Versus Ultrasound-guided Neurostimulator Use In Axillar Brachial Plexus Block. Aydın Sağlık Dergisi, Cilt: 7 - Sayı: 1, 55–69. https://ajindex.com/articles/738525

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. Bloc, S., Mercadal, L., Garnier, T., Komly, B., Leclerc, P., Morel, B., Ecoffey, C., & Dhonneur, G. (2010). Comfort of the patient during axillary blocks placement: a randomized comparison of the neurostimulation and the ultrasound guidance techniques. European journal of anaesthesiology, 27(7), 628–633. doi.org/10.1097/EJA.0b013e328333fc0a [2] Conceição, D. B., Helayel, P. E., & Oliveira Filho, G. R. (2009). A comparative study between ultrasound and neurostimulation guided axillary brachial plexus block. Revista brasileira de anestesiologia, 59(5), 585–591. [3] Danelli, G., Bonarelli, S., Tognú, A., Ghisi, D., Fanelli, A., Biondini, S., Moschini, E., & Fanelli, G. (2012). Prospective randomized comparison of ultrasound-guided and neurostimulation techniques for continuous interscalene brachial plexus block in patients undergoing coracoacromial ligament repair. British journal of anaesthesia, 108(6), 1006–1010. https://doi.org/10.1093/bja/aes031 [4] Denny, N. M., & Harrop-Griffiths, W. (2005). Location, location, location! Ultrasound imaging in regional anaesthesia. British journal of anaesthesia, 94(1), 1–3. doi.org/10.1093/bja/aei001 [5] Dingemans, E., Williams, S. R., Arcand, G., Chouinard, P., Harris, P., Ruel, M., & Girard, F. (2007). Neurostimulation in ultrasound-guided infraclavicular block: a prospective randomized trial. Anesthesia and analgesia, 104(5), 1275-80. doi.org/10.1213/01.ane.0000226101.63736.20 [6] Fuzier, R., Fourcade, O., Fuzier, V., Albert, N., Samii, K., & Olivier, M. (2006). Double- vs. single-injection infraclavicular plexus block in the emergency setting: higher success rate with lower volume of local anaesthetic. European journal of anaesthesiology, 23(4), 271–275.doi.org/10.1017/S0265021506000329 [7] Gürkan, Y., Ozdamar, D., Hoşten, T., Solak, M., & Toker, K. (2009). Ultrasound guided lateral sagital infraclavicular block for pectoral flap release. Agri, 21(1), 39–42. [8] Hogan Q (2003). Finding nerves is not simple. Reg Anesth Pain Med; 28:367-71. [9] Hopkins P. M. (2007). Ultrasound guidance as a gold standard in regional anaesthesia. British journal of anaesthesia, 98(3), 299–301. doi.org/10.1093/bja/ael387 [10] Khabiri, B., Arbona, F. L., & Norton, J. A. (2010). Seizure complicating placement of a nerve stimulator-guided infraclavicular block: could the use of ultrasound decrease the risk?. Journal of clinical anesthesia, 22(8), 627–631. doi.org/10.1016/j.jclinane.2009.09.016 [11] Kumar, A., Sharma, D., Sibi, M. E., D