Journals / Türk Doğa ve Fen Dergisi / 2022 / Cilt: 11 - Sayı: 1

Simulation of Disturbance Observer-Based Bone Tissue Change Prediction Approach for Orthopedic Drills

Ortopedik Matkaplar İçin Bozucu Gözlemci Tabanlı Kemik Doku Değişim Tahmin Yaklaşımı Benzetimi

Pages
136–141
Publication Date
2022-03-25
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The performance of the proposed approach has been proven by simulation study.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Orthopedic drills are currently used for various operations in surgical fields such as orthopedics, ear, nose, and throat surgery.
📊
Key Findings & Data:The path that orthopedic drills travel through the tissue is controlled manually by surgeons, and manual control leads to the risk of damaging areas such as nerves and tissues.
💡
Conclusion & Impact:The performance of the proposed approach has been proven by simulation study.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Ortopedik Matkap · Bozucu Gözlemci · Kemik Delme

Abstract

Orthopedic drills are currently used for various operations in surgical fields such as orthopedics, ear, nose, and throat surgery. The path that orthopedic drills travel through the tissue is controlled manually by surgeons, and manual control leads to the risk of damaging areas such as nerves and tissues. In our study, an innovative approach is presented against existing drill designs and breakthrough detection problems. In the proposed model, the change in the load torque and the change in friction force caused by the tissue change in the drilling path are considered as a disturbance effect, and a disturbance observer has been developed that allows these disturbances to be observed. Observation of the disturbance effects allows the perception of the hardness of tissue change during drilling since it gives the change of load torque changes and friction coefficient, which cannot be measured under normal operation. The performance of the proposed approach has been proven by simulation study.

Özet

Günümüzde ortopedi, kulak burun boğaz gibi cerrahi alanlarda çeşitli operasyonlarda ortopedik matkaplar kullanılmaktadır. Ortopedik matkapların doku içerisindeki kat ettiği yol manuel olarak cerrahlar tarafından kontrol edilmektedir ve manuel kontrol sinir, doku gibi bölgelerde hasar oluşturma riskine yol açmaktadır. Çalışmamızda mevcut matkap tasarımlarına ve sorunlarına karşı yenilikçi bir model sunulmaktadır. Önerilen modelde yük torqueindeki değişim ve matkap ucundaki doku değişikliğinden kaynaklanan sürtünme kuvveti değişimi bozucu etki olarak ele alınmış, bu bozucu etkilerin gözlemlenmesine olanak sağlayan bir bozucu gözlemci geliştirilmiştir. Bozucu etkilerinin gözlemlenmesi, normal şartlarda ölçülemeyen yük torque değişimlerinin ve sürtünme katsayısının değişimini verdiğinden dolayı, delme esnasında doku değişiminin algılanmasına olanak sağlamaktadır. Önerilen yöntemi başarımı benzetim çalışmaları ile kanıtlanmıştır.

🔖

Cite This Article

TORUN, Y. (2022). Simulation of Disturbance Observer-Based Bone Tissue Change Prediction Approach for Orthopedic Drills. Türk Doğa ve Fen Dergisi, Cilt: 11 - Sayı: 1, 136–141. https://ajindex.com/articles/705732

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (4)

  1. N. Bertollo and W. Robert, “Drilling of Bone: Practicality, Limitations and Complications Associated with Surgical Drill-Bits,” in Biomechanics in Applications, 2012. E. Gönen, “Minimally invasive surgical techniques for the treatment of the shaft fractures of the long bones,” Türk Ortop. ve Travmatoloji Birliği Derneği Derg., vol. 11, no. 1, pp. 78–88, 2012, doi: 10.5606/totbid.dergisi.2012.11. O. Farouk, C. Krettek, T. Miclau, P. Schandelmaier, P. Guy, and H. Tscherne, “Minimally invasive plate osteosynthesis: Does percutaneous plating disrupt femoral blood supply less than the traditional technique?,” J. Orthop. Trauma, 1999, doi: 10.1097/00005131-199908000-00002. Y. Torun and A. Öztürk, “A New Breakthrough Detection Method for Bone Drilling in Robotic Orthopedic Surgery with Closed-Loop Control Approach,” Ann. Biomed. Eng., vol. 48, no. 4, 2020, doi: 10.1007/s10439-019-02444-5. R. A. Modi and R. P. Nayak, “Detection of Breakthrough During Bone-Drilling in Orthopaedic Surgery,” vol. 1, no. 9, pp. 794–798, 2014.
  2. Y. Torun, A. Ozturk, N. Hatipoglu, and Z. Oztemur, “Detection of Bone Excretion with Current Sensor in Robotic Surgery,” in UBMK 2018 - 3rd International Conference on Computer Science and Engineering, 2018, doi: 10.1109/UBMK.2018.8566443. A. Öztürk, “Robotik cerrahi matkaplarda güç analizi ile matkap ucu çıkış tespiti,” Cumhuriyet Üniversitesi Fen Bilimleri Enstitüsü, 2019.
  3. Y. Torun, O. Pazarci, and A. Ozturk, “Current Approaches to Bone-Drilling Procedures with Orthopedic Drills,” Cyprus J. Med. Sci., vol. 5, no. 1, pp. 93–98, 2020, doi: 10.5152/cjms.2020.1242. G. Augustin et al., “Cortical bone drilling and thermal osteonecrosis,” Clinical Biomechanics, vol. 27, no. 4. 2012, doi: 10.1016/j.clinbiomech.2011.10.010. M. Praamsma, H. Carnahan, D. Backstein, C. J. H. Veillette, D. Gonzalez, and A. Dubrowski, “Drilling sounds are used by surgeons and intermediate residents, but not novice orthopedic trainees, to guide drilling motions,” Can. J. Surg., 2008.
  4. D. Ho, T. Li, and Q. H. Meng, “Bone Drilling Breakthrough Detection via Energy-Based Signal,” in Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, 2018, vol. 2018-July, doi: 10.1109/EMBC.2018.8512621. G. Zheng and L. P. Nolte, “Computer-Assisted Orthopedic Surgery: Current State and Future Perspective,” Frontiers in Surgery, vol. 2. 2015, doi: 10.3389/fsurg.2015.00066 Y. Torun and Ö. Pazarci, “Parametric Power Spectral Density Estima