Journals / The European Research Journal / 2020 / Cilt: 6 - Sayı: 6

Evaluation of myocardial function in pregnant women with speckle-tracking echocardiography

Pages
615–623
Publication Date
2020-11-04
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Speckle-tracking echocardiography may be used to evaluate the effects of pregnancy and that provide further data on cardiac functions.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objectives: The speckle-tracking technique calculates the regional rate, the strain and the strain rate from two-dimensional gray-scale visualizations.
📊
Key Findings & Data:Methods: One hundred five voluntary pregnant and 35 healthy women of reproductive age were included in the study.
💡
Conclusion & Impact:Speckle-tracking echocardiography may be used to evaluate the effects of pregnancy and that provide further data on cardiac functions.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Strain · echocardiography · tissue Doppler imaging

Abstract

Objectives: The speckle-tracking technique calculates the regional rate, the strain and the strain rate from two-dimensional gray-scale visualizations. The aim of this study was to evaluate with speckle-tracking echocardiography the effects of the first, second and third trimesters of pregnancy on cardiac functions. Methods: One hundred five voluntary pregnant and 35 healthy women of reproductive age were included in the study. For echocardiographic evaluations, the 111 highest-quality visualizations were chosen: 24 cases in the first trimester, 31 cases in the second trimester, 32 cases in the third trimester and 24 healthy women as a control group. Global longitudinal, radial, and circumferential strain, and left ventricular (LV) rotation and twist were evaluated by two-dimensional speckle tracking echocardiography. Results: During pregnancy, the diameter, and volume of the left atrium, LV stroke volume, and the heart rate significantly increased beginning in the first trimester (p < 0.0125). The parameters of pulse-Doppler E velocity and tissue Doppler Em velocity significantly increased in the first trimester (p < 0.0125), whereas in the second and third trimester they decreased to control levels. Global longitudinal strain was significantly decreased in the third trimester of the pregnancy (p < 0.0125). Basal and apical LV rotation and twist were significantly increased in the third trimester of pregnancy (p < 0.0125). LV apical and basal reverse rotation rate were significantly increased in the first trimester of pregnancy (p < 0.0125). Conclusions: In the third trimester global longitudinal strain decreased whereas LV rotation and twist increased. Speckle-tracking echocardiography may be used to evaluate the effects of pregnancy and that provide further data on cardiac functions.

🔖

Cite This Article

ARI, S., ARİ, H., YILMAZ, M., BOZAT, T. (2020). Evaluation of myocardial function in pregnant women with speckle-tracking echocardiography. The European Research Journal, Cilt: 6 - Sayı: 6, 615–623. https://ajindex.com/articles/703963

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Clapp JF III, Capeless E. Cardiovascular function before, during and after the first and subsequent pregnancies. Am J Cardiol 1997;80:1469-73
  2. Amundsen BH, Helle-Valle T, Edvardsen T, Torp H, Crosby J, Lyseggen E, et al. Noninvasive myocardial strain measurement by speckle tracking echocardiography: validation against sonomicrometry and tagged magnetic resonance imaging. J Am Coll Cardiol 2006; 47:789-93
  3. Suffoletto MS, Dohi K, Cannesson M, Saba S, Gorcsan J 3rd. Novel speckle-tracking radial strain from routine black-and-white echocardiographic images to quantify dyssynchrony and predict response to cardiac resynchronization therapy. Circulation 2006;113:960-8
  4. Helle-Valle T, Crosby J, Edvardsen T, Lyseggen E, Amundsen BH, Smith HJ, et al. New noninvasive method for assessment of left ventricular rotation: speckle tracking echocardiography. Circulation 2005;112:3149-56
  5. Teicholz LE, Kreulen T, Herman MW, Gorlin R. Problems in echocardiographic–angiographic correlations in the presence or absence of asynergy. Am J Cardiol 1976;37:7-11
  6. Moran AM, Colan SD, Mauer MB, Geva T. Adaptive mechanisms of left ventricular diastolic function to the physiologic load of pregnancy. Clin Cardiol 2002;25:124-31
  7. Tasar O, Kocabay G, Karagoz A, Kalayci Karabay A, Karabay CY, Kalkan S, et al. Evaluation of left atrial functions by 2-dimensional speckle-tracking echocardiography during healthy pregnancy. J Ultrasound Med 2019;38:2981-8
  8. Kametas NA, McAuliffe F, Hancock J, Chambers J, Nicolaides KH. Maternal left ventricular mass and diastolic function during pregnancy. Ultrasound Obstet Gynecol 2001;18:460-6
  9. Mesa A, Jessurun C, Hernandez A, Adam K, Brown D, Vaughn WK, et al. Left ventricular diastolic function in normal human pregnancy. Circulation 1999;99:511-7
  10. Fok WY, Chan IY, Wong JT, Yu CM, Lau TK. Left ventricular diastolic function during normal pregnancy: assessment by spectral tissue Doppler imaging. Ultrasound Obstet Gynecol 2006;28:789-93
  11. Schannwell CM, Zimmermann T, Schneppenheim M, Plehn G, Marx R, Strauer BE. Left ventricular hypertrophy and diastolic dysfunction in healthy pregnant women. Cardiology 2002;97:73-8
  12. Bamfo JE, Kametas NA, Nicolaides KH, Chambers JB. Reference ranges for tissue Doppler measures of maternal systolic and diastolic left ventricular function. Ultrasound Obstet Gynecol 2007;29:414-20
  13. Savu O, Jurcuţ R, Giuşcă S, van Mieghem T, Gussi I, Popescu BA, et al. Morphological and functional adaptation