Journals / Türk Kardiyoloji Derneği Arşivi / 2019 / Cilt: 47 - Sayı: 5

Axillary artery as alternative access for transcatheter aortic valve implantation in a patient with thoracic and abdominal multilayer flow modulator stents, and in a patient with occluded bilateral carotid and iliac arteries

Aksiller arter, torakal ve abdominal çok katmanlı akış modülatörü stentli bir hasta ile iki taraflı karotis ve iliak arteri tıkanmış bir hastada transkateter aort kapak implantasyonu için alternatif giriş

Pages
399–405
Publication Date
2022-11-05
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Presently described are 2 TAVI cases, onewith thoracoabdominal MLFM stents, and the second withoccluded bilateral carotid and iliac arteries.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Transaxillary access is an alternative tofemoral access in patients with iliofemoral occlusion fortranscatheter aortic valve implantation (TAVI).
📊
Key Findings & Data:A MultilayerFlow Modulator (MLFM) stent is frequently used in patientswith a complex thoracic and abdominal aortic aneurysm.The MLFM stent is particularly used in cases where largearteries, such as the renal or celiac artery, feed from theaneurysmal sac.
💡
Conclusion & Impact:Presently described are 2 TAVI cases, onewith thoracoabdominal MLFM stents, and the second withoccluded bilateral carotid and iliac arteries.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Transaxillary access is an alternative tofemoral access in patients with iliofemoral occlusion fortranscatheter aortic valve implantation (TAVI). A MultilayerFlow Modulator (MLFM) stent is frequently used in patientswith a complex thoracic and abdominal aortic aneurysm.The MLFM stent is particularly used in cases where largearteries, such as the renal or celiac artery, feed from theaneurysmal sac. To the best of our knowledge, there is noprior report in the literature of a TAVI case with a pre-existingMLFM stent. Presently described are 2 TAVI cases, onewith thoracoabdominal MLFM stents, and the second withoccluded bilateral carotid and iliac arteries.

Özet

Aksiller arter girişi iliyofemoral oklüzyonlu hastalarda kateter aracılı aort kapak implantasyonu (TAVI) için alternatif bir yoldur. Kompleks torasik ve abdominal aort anevrizması olan hastalarda çok katmanlı akım modülatörü (MLFM) stenti kullanılır. MLFM stent, özellikle böbrek arteri, çölyak arter gibi geniş arterlerin anevrizmal kesesi içinden çıktığı durumunda kullanılır. Literatürde MLFM stentli hastada rapor edilmiş TAVI olgusu yoktur. Bu yazıda, biri torasik ve abdominal aortada MLFM stenti ve diğeri iki taraflı karotis ve iliyak arterleri tıkalı olan, aksiller arter aracılığı ile TAVI uygulanan iki olguyu sunuyoruz.

🔖

Cite This Article

Melek, M., ARI, H., Arı, S., Karakuş, A., Çamcı, S. (2022). Axillary artery as alternative access for transcatheter aortic valve implantation in a patient with thoracic and abdominal multilayer flow modulator stents, and in a patient with occluded bilateral carotid and iliac arteries. Türk Kardiyoloji Derneği Arşivi, Cilt: 47 - Sayı: 5, 399–405. https://ajindex.com/articles/632101

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Figulla L, Neumann A, Figulla HR, Kahlert P, Erbel R, Neumann T. Transcatheter aortic valve implantation: evidence on safety and efficacycompared with medical therapy. A systematic review of current literature. Clin Res Cardiol 2011;100:265−76
  2. Petronio AS, De Carlo M, Giannini C, De Caro F, Bortolotti U. Subclavian TAVI: more than an alternative access route. EuroIntervention 2013;9 Suppl:S33−7. 3. da Gama Ribeiro V, Vouga L, Markowitz A, Bezerra HG, Braga P, Ansari M, et al. Vascular access in transcatheter aortic valve implantation. Int J Cardiovasc Imaging 2011;27:1235−43
  3. Ruge H, Lange R, Bleiziffer S, Hutter A, Mazzitelli D, Will A, et al. First successful aortic valve implantation with the CoreValve ReValving Systemvia right subclavian artery access: a case report. Heart Surg Forum 2008;11:E323−4
  4. Raux M, Patel VI, Cochennec F, Mukhopadhyay S, Desgranges P, Cambria RP, et al. A propensity-matched comparison of outcomes for fenestrated endovascular aneurysm repair and open surgical repair of complex abdominal aortic aneurysms. J Vasc Surg 2014;60:858−64
  5. Sultan S, Sultan M, Hynes N. Early mid-term results of the first 103 cases of multilayer flow modulator stentdone under indication for use in the management of thoracoabdominal aorticpathology from the independent global MFM registry. J Cardiovasc Surg (Torino) 2014;55:21−32
  6. Gilard M, Eltchaninoff H, Iung B, Donzeau-Gouge P, Chevreul K, Fajadet J, et al. Registry of transcatheter aortic- valve implantation in high-risk patients. N Engl J Med 2012;366:1705−15
  7. Schäfer U, Ho Y, Frerker C, Schewel D, Sanchez-Quintana D, Schofer J, et al. Direct percutaneous access technique for transaxillary transcatheter aortic valve implantation: “the Hamburg Sankt Georg approach”. JACC Cardiovasc Interv 2012;5:477−86
  8. Walther T, Schuler G, Borger MA, Kempfert J, Seeburger J, Rückert Y, et al. Transapical aortic valve implantation in 100 consecutive patients: comparisonto propensitymatched conventional aortic valve replacement. Eur Heart J 2010;31:1398−403
  9. Guyton RA, Block PC, Thourani VH, Lerakis S, Babaliaros V. Carotid artery access for transcatheter aortic valve replacement. Catheter Cardiovasc Interv 2013;82:E583−6
  10. Hamm CW, Möllmann H, Holzhey D, Beckmann A, Veit C, Figulla HR, et al. The German Aortic Valve Registry (GARY): in-hospital outcome. Eur Heart J 2014;35:1588−98
  11. Rogers T, Lederman RJ. Percutaneous transaxillary access for TAVR: Another opportunity to stay out of