Journals / Mühendislik Bilimleri ve Tasarım Dergisi / 2021 / Cilt: 9 - Sayı: 3

IDENTIFYING THE IMPROVEMENT POSSIBILITIES OF A FLUIDIZED BED BOILER WITH EXERGY ANALYSIS

EKSERJİ ANALİZİ İLE BİR AKIŞKAN YATAKLI KAZANIN İYİLEŞTİRME OLANAKLARININ TESPİT EDİLMESİ

Pages
911–922
Publication Date
2021-09-21
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

It showed its effect as an increase in some sub-systems and a decrease in others.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, a circulation-type fluidized bed boiler's exergy performance in a power generation plant was investigated.
📊
Key Findings & Data:In the analysis, the sub-systems' exergy performance was evaluated in terms of criteria such as exergy efficiency, exergy destruction, fuel depletion ratio, relative exergy destruction ratio, exergetic improvement potential, and productivity lack ratio.
💡
Conclusion & Impact:It showed its effect as an increase in some sub-systems and a decrease in others.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Akışkan Yatak · Kazan · Ekserji Verimi

Abstract

In this study, a circulation-type fluidized bed boiler's exergy performance in a power generation plant was investigated. The boiler was examined not as a whole but by dividing it into its sub-systems. In the analysis, the sub-systems' exergy performance was evaluated in terms of criteria such as exergy efficiency, exergy destruction, fuel depletion ratio, relative exergy destruction ratio, exergetic improvement potential, and productivity lack ratio. In addition, the effect of different dead state temperatures on these exergy performance criteria is compared and discussed. As a result of the analysis, the highest exergy efficiency was achieved in the furnace with 80.2% at 6℃, while the highest exergy destruction occurred in the furnace as 18,118.9 kW at 27℃. The highest exergetic improvement potential was realized in Economizer-II with 11,593.82 kW at 6℃, and the lowest in Economizer-I at 27℃ with 631,9 kW. The effect of the increase in the dead state temperature on the exergy performance criteria applied to boiler sub-systems was variable. It showed its effect as an increase in some sub-systems and a decrease in others.

Özet

Bu çalışmada, bir güç üretim tesisinde kullanılan dolaşım tipli akışkan yataklı kazanın ekserji performansı araştırılmıştır. Kazan bir bütün olarak değil, alt sistemlerine ayrılarak incelemeye tabi tutulmuştur. Analizde alt sistemlerin ekserji performansı, ekserji verimliliği, ekserji yıkımı, nispi ekserji yıkımı oranı, yakıt tüketme oranı, ekserjetik gelişim potansiyeli ve üretkenlik eksikliği oranı gibi kriterler bakımından değerlendirilmiştir. Ayrıca, farklı ölü hal sıcaklıklarının bu ekserji performans kriterleri üzerindeki etkisi kıyaslanmış ve tartışılmıştır. Yapılan analizler sonucunda en yüksek ekserji verimi %80,2 ile 6℃’de yanma odasında, en yüksek ekserji yıkımı ise yine yanma odasında 27℃’de 18.118,9 kW olarak gerçekleşmiştir. En yüksek ekserjetik gelişim potansiyeli 11.593,82 kW ile 6℃’de eko-II’de, en düşük ise 631,9 kW ile 27℃’de eko-I’de gerçekleşmiştir. Ölü hal sıcaklığındaki artışın kazan alt sistemlerine uygulanan ekserji performans kriterleri üzerindeki etkisi değişken olmuştur. Kimi alt sistemde artış kimi alt sistemde ise düşüş olarak etkisini göstermiştir.

🔖

Cite This Article

YAZICI, M., BAYRAKTAR, F. S., KÖSE, R. (2021). IDENTIFYING THE IMPROVEMENT POSSIBILITIES OF A FLUIDIZED BED BOILER WITH EXERGY ANALYSIS. Mühendislik Bilimleri ve Tasarım Dergisi, Cilt: 9 - Sayı: 3, 911–922. https://ajindex.com/articles/693297

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (15)

  1. Akkurt, F., Kahraman, A., 2017. An Exergy Analysis of Solar-Assisted Ejector Cooling System for Different Area Raatios at Their Maximum COP Values. Thermal Sciences, 23, 179-190.
  2. Aljundi, I.H., 2009. Energy and Exergy Analysis of A Steam Power Plant in Jordan. Applied Thermal Engineering, 29, 324-328.
  3. Balli, O., Aras, H., Aras, N., Hepbasli, A., 2008. Exergetic and Exergoeconomic Analysis of An Aircraft Jet Engine. International Journal of Exergy, 5, 567-581.
  4. Behbahaninia, A., Ramezani, S., Hejrandoost, M.L., 2017. A Loss Method for Exergy Auditing of Steam Boilers. Energy, 140,253-260.
  5. Callak, M., Balkan, F., Hepbasli, A., 2015. Avoidable and Unavoidable Exergy Destructions of A Fluidized Bed Coal Combustor and A Heat Recovery Steam Generator. Energy Conversion and Management, 98, 54-58.
  6. Çengel, Y.A., Boles, M.A., 2008. Thermodynamics on Engineering Approach (6th Edition) page 445 ISBN 978-0-07-125771-8.
  7. Dincer, I., Rosen, M.A., 2007.
  8. Exergy, Energy, Environment and Sustainable Development. Elsevier Elhelw, M., Dahma, K.S., Attia, A., 2019. Utilizing Exergy Analysis in Studying the Performance of Steam Power Plant at Two Different Operation Mode. Applied Thermal Engineering, 150, 285-293.
  9. Erdem, H.H., Akkaya, A.V., Cetin, B., Dagdas, A., Sevilgen, S.H., Sahin, B., Teke, I., Gungor, C., Atas, S., 2009. Comparative Energetic and Exergetic Performance Analyses for Coal Fired Thermal Power Plants in Turkey. International Journal of Thermal Sciences, 48,2179-2186.
  10. Eskin, N., Kilic, A., 1996. Estimation of Cooling Tube Location in Fluidized Bed Coal Combustors Through Exergy Analysis. Energy Conversion and Management, 37 (9), 1453-1461.
  11. Eskin, N., Gungor, A., Özdemir, K., 2009. Thermodynamic Analysis of A FBC Steam Power Plant. Energy Conversion and Management, 50, 2428-2438.
  12. Ganapathy, T., Alahumurthi, N., Gakkhar, R.P., Murugesan, K., 2009. Exergy Analysis of Operating Lignite Fired Thermal Power Plant. Journal of Engineering Science and Technology Review, 2 (1), 123-130.
  13. Gürtürk, M., Oztop, H.F., 2016. Exergy Analysis of A Circulating Fluidized Bed Boiler Cogeneration Power Plant. Energy Conversion and Management, 120, 346-357.
  14. Hepbasli, A., 2009. Exergetic Modeling of Oil Shale-Fired Circulating Fluidized Bed Systems. Energy Sources, Part A: Recovery, Utilization, and Environmental Effects, 31:4, 325-337.
  15. İpek, O., Kılıç, B., Gürel, B., 2017. Experimental Investigation of Exergy Loss Analysis in Newly Designed Compact Heat Exchangers. Energy, 124, 330-335.