The Effect of ChromaGen Contact Lenses on Corneal Clarity: A Corneal Densitometry

Pages
89–94
Publication Date
2022-11-06
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Further studies with longer follow-up are required to determine the long-term effects and detect differing effects of CCL with different base curves.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objectives: The purpose of this study is to investigate the effect of ChromaGen contact lens (CCL) on corneal clarity, expressed through the measurement of corneal densitometry (CD) values.
📊
Key Findings & Data:Methods: This study included 22 eyes of 22 patients with congenital red-green color vision deficiency who were admitted to our clinic for the CCL trial.
💡
Conclusion & Impact:Further studies with longer follow-up are required to determine the long-term effects and detect differing effects of CCL with different base curves.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Objectives: The purpose of this study is to investigate the effect of ChromaGen contact lens (CCL) on corneal clarity, expressed through the measurement of corneal densitometry (CD) values. Methods: This study included 22 eyes of 22 patients with congenital red-green color vision deficiency who were admitted to our clinic for the CCL trial. After a detailed ophthalmological examination and CD measurement with Pentacam HR (Oculus Optikgerate GmbH, Wetzlar, Germany), the most appropriate CCLs were defined through pseudoisochromatic plates and inserted for 2 h. The CD measurement was repeated after the removal of the CCL. Comparison was made of CD values before and after the insertion of the most appropriate CCL. The after-CCL/before-CCL ratio was calculated, and the effect of CCL type on this ratio was investigated. Results: The after-CCL values were higher in the anterior, central, posterior, and total thickness of the 0–2 mm concentric zone (p=0.044, p=0.040, p=0.021, and p=0.032, respectively) when compared to the before-CCL values. There was no statistically significant difference between before-CCL and after-CCL values in any layer of the 2–6, 6–10, and 10–12 mm concentric zones (p>0.05, for all). After-CCL/before-CCL ratios were similar in the Magenta2 (M2), Magenta3 (M3), and Violet3 (V3) types of CCLs (p>0.017). Conclusion: Usage for 2 h of CCL was observed to increase CD values in all layers of the 0–2 mm concentric zone irrespective of the type of CCL. Further studies with longer follow-up are required to determine the long-term effects and detect differing effects of CCL with different base curves.

🔖

Cite This Article

İLHAN, Ç., ŞEKEROĞLU, M. A., DOĞUİZİ, S., YILMAZBAŞ, P. (2022). The Effect of ChromaGen Contact Lenses on Corneal Clarity: A Corneal Densitometry. BEYOGLU EYE JOURNAL, Cilt: 7 - Sayı: 2, 89–94. https://ajindex.com/articles/649058

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (16)

  1. Harris D. Colouring sight: A study of CL fitting with colour-enhancing lenses. Optician 1997;213:38–41
  2. Quantock AJ, Winkler M, Parfitt GJ, Young RD, Brown DJ, Boote C, et al. From nano to macro: studying the hierarchical structure of the corneal extracellular matrix. Exp Eye Res 2015;133:81–99
  3. Swartz T, Marten L, Wang M. Measuring the cornea: The latest developments in corneal topography. Curr Opin Ophthalmol 2007;18:325–33
  4. Piñero DP. Technologies for anatomical and geometric characterization of the corneal structure and anterior segment: A review. Semin Ophthalmol 2015;30:161–70
  5. Nemeth G, Hassan J, Modis L Jr., Hassan Z. Long-term changes in backscattered light measurements in keratoconus corneas treated with collagen cross-linking. Curr Eye Res 2017;7:1–9
  6. Tekin K, Inanc M, Kurnaz E, Bayramoglu E, Aydemir E, Koc M, et al. Objective evaluation of corneal and lens clarity in children with Type 1 diabetes mellitus. Am J Ophthalmol 2017;179:190– 7
  7. Cankaya AB, Tekin K, Inanc M. Effect of pseudoexfoliation on corneal transparency. Cornea 2016;35:1084–8
  8. Cole BL, Lian KY, Lakkis C. The new Richmond HRR pseudoisochromatic test of colour vision is better than the Ishihara test. Clin Exp Optom 2006;89:73–80
  9. Turhan SA, Toker E. Changes in corneal density after accelerated corneal collagen cross-linking with different irradiation intensities and energy exposures: 1-year follow-up. Cornea 2017;36:1331–5
  10. Anayol MA, Bostancı B, Şekeroğlu MA, Simsek M, Günaydın S, Yılmazbaş P. Assessment of corneal densitometry in rheumatoid arthritis patients. Turk J Ophthalmol 2017;47:125–9
  11. Asena L, Altınörs DD, Cezairlioğlu Ş, Bölük SO. Effect of dry eye on Scheimpflug imaging of the cornea and elevation data. Can J Ophthalmol 2017;52:313–7
  12. Otri AM, Fares U, Al-Aqaba MA, Dua HS. Corneal densitometry as an indicator of corneal health. Ophthalmology 2012;119:501–8
  13. Baratz KH, McLaren JW, Maguire LJ, Patel SV. Corneal haze determined by confocal microscopy 2 years after Descemet stripping with endothelial keratoplasty for Fuchs corneal dystrophy. Arch Ophthalmol 2012;130:868–74
  14. Enders P, Holtick U, Schaub F, Tuchscherer A, Hermann MM, Scheid C, et al. Corneal densitometry for quantification of corneal deposits in monoclonal gammopathies. Cornea 2017;36:470–5
  15. Lopes B, Ramos I, Ambrósio R Jr. Corneal densitometry in keratoconus. Cornea 2014;33:1282–6
  16. Efron N, Ang JH. Corneal hypoxia and hypercapnia during contact lens wear