Journals / Türk Nefroloji Diyaliz ve Transplantasyon Dergisi / 2013 / Cilt: 22 - Sayı: 3

Arteriovenöz fistül ve psodoanevrizma: böbrek biyopsinin nadir fakat önemli iki komplikasyonu ve 16 g otomatik biyopsi iğnesinin güvenilirliği

Arteriovenous fistula and pseudoaneurysm: two ımportant but rare complications of percutaneous renal biopsy and safety of the 16 g automated biopsy needle

Pages
283–289
Publication Date
2022-11-05
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

RBC counts per high power field increased significantly after the procedure in all subjects (p

📌 3 Key Takeaways

🎯
Objective & Hypothesis:OBJECTIVE: The aim of this study was to evaluate the safety of 16 G automated biopsy needles, and the incidence of AVF and pseudoaneurysm in patients undergoing renal biopsy.
📊
Key Findings & Data:MATERIAL and METHODS: Patients who underwent renal biopsy from January 2010 to December 2012 were prospectively evaluated.
💡
Conclusion & Impact:RBC counts per high power field increased significantly after the procedure in all subjects (p
🔬Design:Research Article
📍Scope:2010 Verileri
⚙️Variables:Domain Parameters

Abstract

OBJECTIVE: The aim of this study was to evaluate the safety of 16 G automated biopsy needles, and the incidence of AVF and pseudoaneurysm in patients undergoing renal biopsy. MATERIAL and METHODS: Patients who underwent renal biopsy from January 2010 to December 2012 were prospectively evaluated. Color Doppler USG, hemoglobin and platelet counts, spot urine analysis were performed perormed before and after the biopsy procedure, AVF and pseudoaneurysm that developed secondary to percutaneous renal biopsy were evaluated by Doppler USG at 12 h, and 24 h, and 6 and 12 months after biopsy. RESULTS: Postbiopsy small perirenal, subcapsular, or parenchymal bleeding without clinical relevance were detected in 59 patients (89.2 %) 12 and 24 hours after procedure. RBC counts per high power field increased significantly after the procedure in all subjects (p

Özet

AMAÇ: Bu çalışmanın amacı, nefrotik sendrom nedeni ile böbrek biyopsisi yapılan hastalarda, psödoanevrizma ve A-V fistül sıklığını, 16 G otomatik biopsi iğnesinin güvenilirliğini değerlendirmektir. GEREÇ ve YÖNTEMLER: Çalışmaya Ocak 2010 ile Aralık 2012 yılları arasında nefrotik sendrom tanısı nedeni ile böbrek biyopsisi yapılan hastalar alındı. Biyopsi işleminden sonra psödoanevrizma ve A-V fistül gelişip gelişmediğini değerlendirmek için işlem sonrası 12. saat, 24. saat, 6. ay ve 12. ayda hastalar renkli Doppler USG, hemogram, trombosit değerleri ve spot idrar tahlil sonuçları ile değerlendirildi. BULGULAR: Biyopsi işlemi sonrasında 12. Saat ve 24. saatlerde 59 hastada (% 89.2) klinik önem taşımayan perirenal, subkapsüler ve parenkimal kanama saptandı. 12. ve 24. saatlerde gözlenen mikroskobik hematüri oranı 6. ay ve 12. aylarda görülen mikroskobik hematüri oranına göre istatistiksel olarak anlamlı oranda yüksek saptandı (p

🔖

Cite This Article

TURGUTALP, K., KIYKIM, A., KÖŞECİ, T., APAYDIN, D. (2022). Arteriovenöz fistül ve psodoanevrizma: böbrek biyopsinin nadir fakat önemli iki komplikasyonu ve 16 g otomatik biyopsi iğnesinin güvenilirliği. Türk Nefroloji Diyaliz ve Transplantasyon Dergisi, Cilt: 22 - Sayı: 3, 283–289. https://ajindex.com/articles/636333

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Vogler C, Wang Y, Brink DS, Wood E, Belsha C, Walker PD: Renal pathology in the pediatric transplant patient. Adv Anat Pathol 2007; 14: 202-216
  2. Furness PN, Philpott CM, Chorbadjian MT, Nicholson ML, Bosmans JL, Corthouts BL, Bogers JJ, Schwarz A, Gwinner W, Haller H, Mengel M, Seron D, Moreso F, Cañas C: Protocol biopsy of the stable renal transplant: A multicenter study of methods and complication rates. Transplantation 2003;76: 969-973
  3. Feneberg R, Schaefer F, Zieger B, Waldherr R, Mehls O, Schärer K: Percutaneous renal biopsy in children: A 27-year experience. Nephron 1998; 79: 438-446
  4. Matsell DG, Jones DP, Boulden TF, Burton EM, Baum SL, Tonkin IL: Arteriovenos fistula after biopsy of renal transplant kidney: Diagnosis and treatment. Pediatr Nephrol 1992; 6: 562-564
  5. Brandenburg VM, Frank RD, Riehl J: Color-coded duplex sonography study of arteriovenous fistulae and pseudoaneurysms complicating percutaneous renal allograft biopsy. Clin Nephrol 2002; 58: 398-404
  6. Tarif N, Dunne PM, Parachuru PR, Bakır AA: Life-threatening hematuria from an arteriovenous fistula complicating an open renal biopsy. Nephron 1998; 80: 66-70
  7. Riccabona M, Schwinger W, Ring E: Arteriovenous fistula after renal biopsy in children. J Ultrasound Med 1998; 17: 505-508
  8. Riehl J, Maigatter S, Kierdorf H, Schmitt H, Maurin N, Sieberth HG: Percutaneous renal biopsy: Comparison of manual and automated puncture techniques with native and transplanted kidneys. Nephrol Dial Transplant 1994; 9: 1568-1574
  9. Rüth EM, Dittrich K, Jüngert J, Uder M, Rascher W, Dötsch J: Successful interventional treatment of arteriovenous fistula after kidney biopsy in paediatric patients-a report of three cases. Nephrol Dial Transplant 2008; 23: 3215-3218
  10. Omoloja AA, Racadio JM, McEnery PT: McEnery: Post-biopsy renal arteriovenous fistula. Pediatr Transplantation 2002; 6: 82-85 Alcázar R, de la Torre M, Peces R: Symptomatic intrarenal arteriovenous fistula detected 25 years after percutaneous renal biopsy. Nephrol Dial Transplant 1996; 11: 1346-1348
  11. Racusen LC, Solez K, Colvin RB, Bonsib SM, Castro MC, Cavallo T, Croker BP, Demetris AJ, Drachenberg CB, Fogo AB, Furness P, Gaber LW, Gibson IW, Glotz D, Goldberg JC, Grande J, Halloran PF, Hansen HE, Hartley B, Hayry PJ, Hill CM, Hoffman EO, Hunsicker LG, Lindblad ES, Marcussen N, Mihatsch MJ, Nadasdy T, Nickerson P, Olsen TS, Papadimitriou JC, Randhawa PS, Rayner DC, Roberts I, Rose S, Rush D, Madrigal LS, Salomon DR, Sund S, Taskinen E, Trpkov K, Yamaguchi Y: The Ban