A simple, reproducible, noninvasive myocardial performance index (MPI) for the assessment of overall cardiac function has been described previously.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:A simple, reproducible, noninvasive myocardial performance index (MPI) for the assessment of overall cardiac function has been described previously.
📊
Key Findings & Data:The purpose of this study was to compare the MPI obtained by pulsed Doppler method with the MPI obtained by tissue Doppler echocardiography (TDE) in normal subjects.
💡
Conclusion & Impact:At all sites measured, MPI by TDE correlated well with conventional MPI (at septal site r=0.82, p
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

A simple, reproducible, noninvasive myocardial performance index (MPI) for the assessment of overall cardiac function has been described previously. The purpose of this study was to compare the MPI obtained by pulsed Doppler method with the MPI obtained by tissue Doppler echocardiography (TDE) in normal subjects. Twenty-eight healthy subjects were included. In order to calculate MPI by TDE, isovolumetric contraction (IVCT), relaxation time (IVRT) and ejection time (ET) were measured at two different sites of mitral annulus: septum and lateral. MPI was calculated by dividing the sum of IVCT and IVRT by ET at each site of measurement. The mean MPI value was found by dividing the sum of these MPI values into two. The same parameters were measured using the mitral inflow and left ventricular outflow velocity time intervals in pulsed Doppler method. At all sites measured, MPI by TDE correlated well with conventional MPI (at septal site r=0.82, p

Özet

Miyokard performans indeksi (MPİ) basit, kullanılabilir ve girişimsel olmayan bir yöntem olarak kardiyak fonksiyonları değerlendirmek amacıyla daha önce tanımlanmıştır. Bu çalışmanın amacı sağlıklı bireylerde pulse Doppler metodu ile elde edilen MPİ'ni doku Doppler (DD) metodu ile elde edilen MPİ ile karşılaştırmaktır. Çalışmaya 28 sağlıklı birey alındı. DD ile elde edilen MPİ'ni hesaplamak amacıyla izovolumetrik kontraksiyon (İVKZ), izovolumetrik relaksasyon (İVRZ) ve ejeksiyon zamanı (EZ) mitral anulusun iki farklı bölgesinden (septum ve lateral) alındı. MPİ her bir bölgeden ölçülen İVRZ ve İVKZ toplamının EZ'na bölünmesi ile hesaplandı. Ortalama MPİ değeri hesaplanan MPİ değerlerinin ikiye bölünmesi ile elde edildi. Aynı parametreler mitral giriş ve sol ventrikül çıkış yolu hız zaman intervalleri kullanılarak pulsed Doppler metodu ile ölçüldü. Ölçülen tüm bölgelerde, DD ile elde edilen MPİ pulsed Doppler metodu ile hesaplanan MPİ ile iyi derecede korelasyon göstermekte idi (septal bölge r=0.82, p

🔖

Cite This Article

ONBAŞILI, A. O., ÜNAL, S., AĞAOĞLU, P., CEYHAN, C., TEKTEN, T. (2022). Doku Doppler miyokard performans indeksi. Türk Kardiyoloji Derneği Arşivi, Cilt: 31 - Sayı: 5, 262–269. https://ajindex.com/articles/633889

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. Tei C, Ling LH, Hodge DO, et al. New index combined systolic and diastolic myocardial performance: a simple and reproducible measure of cardiac function: a study in normals and dilated cardiomyopathy. J Cardiol 1995; 26:357-66 2. Tei C. New non-invasive index for combined systolic and diastolic function. J Cardiol 1995;26:396-404 3. Tei C, Dujardin KS, Hodge DO, Kyle RA, Tajik AJ, Seward BJ. Doppler index combining systolic and diastolic myocardial performance: clinical value in cardiac amyloidosis. J Am Coll Cardiol 1996;28:658-64 4. Sutherland GR. Doppler myocardial imaging: Rationale, principles and instrumentation. In Proceedings of the International Summit in Doppler Tissue Imaging. Madrid, April, 1977, pp.17-23 5. Galiuto L, Ignone G, DeMaria AN. Contraction and relaxation velocities of the normal left ventricle using pulsed-wave tissue Doppler echocardiography. Am J Cardiol 1998;8l:609-14 6. Yamazaki N, Mine Y, Şano A, et al. Analysis of ventricular wall motion using color-coded using tissue Doppler imaging system. Jpn J Appl Physiol 1994;33:3141-6 7. Schiller NB, Shall PM, Crawford M, ct al. Recomendations for quantitation of the left ventricle by two-dimensional echocardiography. J Am Soc Echocardiogr 1989;2:358-67 8. Poulsen SH, Jensen SE, Tei C, Seward JB, Egstrup K. Value of Doppler index of performance in the early phase of acute myocardial infarction. J Am Sec Echocardİogr 2000;13:723-30 9. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurements. Lancet 1986;1:3O7-1O 10. Harada K, Tamum M, Toyono M, Yasuoka K. Comparison of the right ventricular Tei index by tissue Doppler imaging to that obtained by pulsed Doppler in children without heart disease. Am J Cardiol 2002;90:566-9 11. Harada K, Tamımı M, Toyono M, Oyama K, Takada G. Assessment of global left ventricular function by tissue Doppler imaging. Am J Cardiol 2001;88:927-32 12. Rushmer RE Cardiovascular Dynamics. 4th ed. Philadelphia: WB Saunders; 1976. p. 93 13. LundbackS. Cardiac pumping and the function of the ventricular septum. Acta Physiol Scand 1986;550 (Suppl) 1-101 14. Tci C, NLshimura AR, Seward JB, Tajik AJ. Nonİnvasive Doppler-derived myocardial performance index: Correlation with simultaneous measurements of cardiaccatheterization measurements. J Am Sac Echocardiogr 1997;10:169-78