Objective & Hypothesis:A 43-year-old male with a history of dilatedcardiomyopathy and a cardiac resynchronization therapy(CRT) defibrillator (Unify Quadra; St.
📊
Key Findings & Data:Paul, MN, USA) implanted 5 years earlierfor primary prevention presented at the cardiac rhythmand device clinic for regular follow-up.
💡
Conclusion & Impact:What are the next steps?What caused the reduced biventricular pacing, and whatcircumstances should be considered in this case?
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

A 43-year-old male with a history of dilatedcardiomyopathy and a cardiac resynchronization therapy(CRT) defibrillator (Unify Quadra; St. Jude MedicalInc., St. Paul, MN, USA) implanted 5 years earlierfor primary prevention presented at the cardiac rhythmand device clinic for regular follow-up. Device interrogationshowed normal parameters (Table 1). The devicewas programmed in DDD mode at 60 ppm with sensedand paced atrioventricular (AV) delays of 120 millisecondsand 150 milliseconds, respectively. Biventricularpacing was at 50%. The patient’s clinical and echocardiographicsituation had not improved since CRT implantation.The echocardiogram revealed a severely dilatedleft ventricle with an ejection fraction of 20%. Thedevice diagnostic summary showed 48% prematureventricular complexes (PVCs), inhibiting biventricularpacing (Fig. 1). However, there were no PVCs observedduring device interrogation. What are the next steps?What caused the reduced biventricular pacing, and whatcircumstances should be considered in this case?

🔖

Cite This Article

Baranchuk, A., GUL, E., Melhem, M., Amoudi, O. A., Haseeb, S. (2022). Reduced biventricular pacing: What is the mechanism and how to manage it?. Türk Kardiyoloji Derneği Arşivi, Cilt: 47 - Sayı: 3, 216–217. https://ajindex.com/articles/632022

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (2)

  1. Sinner GJ, Gupta VA, Seratnahaei A, Charnigo RJ, Darrat YH, Elayi SC, et al. Atrioventricular dyssynchrony from empiric device settings is common in cardiac resynchronization therapy and adversely impacts left ventricular morphology and function. Echocardiography 2017;34:496–503
  2. Swerdlow CD, Asirvatham SJ, Ellenbogen KA, Friedman PA. Troubleshooting implanted cardioverter defibrillator sensing problems I. Circ Arrhythm Electrophysiol 2014;7:1237–61.