⚡ TL;DR(Too Long; Didn't Read)

Patients with recurrence were older and had higher rates of hypertension and diabetes (p

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: The aim of this research was to investigate the re- lationship between atrial fibrillation (AF) recurrence and sec- ond generation cryoballoon ablation (CBA) procedural pa- rameters in patients with non-valvular paroxysmal AF (PAF).Methods: A total of 131 patients with a PAF diagnosis who underwent second-generation CBA (59 male; mean age: 55.2±10.6 years) were enrolled.
📊
Key Findings & Data:Recurrence was defined as the detection of AF on a 12-lead electrocardiography (ECG) recording, or an attack lasting at least 30 seconds observed on Holter ECG records.
💡
Conclusion & Impact:Patients with recurrence were older and had higher rates of hypertension and diabetes (p
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Objective: The aim of this research was to investigate the re- lationship between atrial fibrillation (AF) recurrence and sec- ond generation cryoballoon ablation (CBA) procedural pa- rameters in patients with non-valvular paroxysmal AF (PAF).Methods: A total of 131 patients with a PAF diagnosis who underwent second-generation CBA (59 male; mean age: 55.2±10.6 years) were enrolled. Recurrence was defined as the detection of AF on a 12-lead electrocardiography (ECG) recording, or an attack lasting at least 30 seconds observed on Holter ECG records. CBA procedural data and echocar- diographic findings were recorded and compared.Results: After 1 year of follow-up, AF recurrence was de- tected in 27 patients. Patients with recurrence were older and had higher rates of hypertension and diabetes (p

Özet

Amaç: Bu çalışmada, valvüler olmayan paroksismal atriyal fibrilasyonu (PAF) olan hastalarda AF nüksü ile ikinci jene- rasyon kriyobalon ablasyon (KBA) prosedürü parametreleri arasındaki ilişkiyi araştırmayı planladık. Yöntemler: İkinci jenerasyon KBA (59 erkek; ort. yaş 55.2±10.6 yıl) yapılan PAF tanısı alan 131 hasta dahil edil- di. Nüks, 12 derivasyonlu elektrokardiyografide (EKG) AF görülmesiyle ya da ritim Holter kayıtlarında en az 30 saniye süren AF ataklarının saptanması olarak tanımlandı. Bazı KBA prosedür verileri ve ekokardiyografik bulgular kayde- dildi ve karşılaştırıldı. Bulgular: Bir yıl sonra izlemde 27 hastada AF nüks tes-pit edildi. Nüksü olan hastalar daha yaşlıydı ve daha yüksek hipertansiyon ve diyabet oranları vardı (hepsi için, p

🔖

Cite This Article

KOCA, H., İÇEN, Y. K., DÖNMEZ, Y., KOÇ, M., ŞAHİN, D. Y., DEMİRTAŞ, A. O., KAYPAKLI, O. (2022). Effect of cryoballoon ablation parameters on recurrence in patients with paroxysmal atrial fibrillation. Türk Kardiyoloji Derneği Arşivi, Cilt: 47 - Sayı: 6, 440–448. https://ajindex.com/articles/631839

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Stewart S, Hart CL, Hole DJ, McMurray JJ. Population preva- lence, incidence, and predictors of atrial fibrillation in the Renfrew/Paisley study. Heart 2001;86:516–21
  2. Kirchhof P, Benussi S, Kotecha D, Ahlsson A, Atar D, Casadei B, et al; ESC Scientific Document Group. 2016 ESC Guide- lines for the management of atrial fibrillation developed in collaboration with EACTS. Eur Heart J 2016;37:2893–962
  3. Su W, Kowal R, Kowalski M, Metzner A, Svinarich JT, Wheelan K, et al. Best practice guide for cryoballoon ablation in atrial fibrillation: The compilation experience of more than 3000 procedures. Heart Rhythm 2015;12:1658–66
  4. Fürnkranz A, Bordignon S, Dugo D, Perotta L, Gunawardene M, Schulte-Hahn B, et al. Improved 1-year clinical success rate of pulmonary vein isolation with the second-generation cryoballoon in patients with paroxysmal atrial fibrillation. J Cardiovasc Electrophysiol 2014;25:840–4
  5. Chierchia GB, Di Giovanni G, Ciconte G, de Asmundis C, Conte G, Sieira-Moret J, et al. Second-generation cryoballoon ablation for paroxysmal atrial fibrillation: 1-year follow-up. Europace 2014;16:639–44
  6. Akkaya E, Berkowitsch A, Zaltsberg S, Greiss H, Hamm CW, Sperzel J, et al. Second-generation cryoballoon ablation as a first-line treatment of symptomatic atrial fibrillation: Two- year outcome and predictors of recurrence after a single pro- cedure. Int J Cardiol 2018;259:76–81
  7. Ahmed H, Neuzil P, Skoda J, D’Avila A, Donaldson DM, Laragy MC, et al. The permanency of pulmonary vein isola- tion using a balloon cryoablation catheter. J Cardiovasc Elec- trophysiol 2010;21:731–7
  8. Ghosh J, Martin A, Keech AC, Chan KH, Gomes S, Singara- yar S, et al. Balloon warming time is the strongest predic- tor of late pulmonary vein electrical reconnection following cryoballoon ablation for atrial fibrillation. Heart Rhythm. 2013;10:1311–7
  9. Fürnkranz A, Köster I, Chun KR, Metzner A, Mathew S, Kon- stantinidou M, et al. Cryoballoon temperature predicts acute pulmonary vein isolation. Heart Rhythm 2011;8:821–5
  10. Ghosh J, Sepahpour A, Chan KH, Singarayar S, McGuire MA. Immediate balloon deflation for prevention of persistent phrenic nerve palsy during pulmonary vein isolation by bal- loon cryoablation. Heart Rhythm 2013;10:646–52
  11. Neumann T, Vogt J, Schumacher B, Dorszewski A, Kuniss M, Neuser H, et al. Circumferential pulmonary vein isolation with the cryoballoon technique results from a prospective 3-center study. J Am Coll Cardiol 2008;52:273–8. 1