Journals / Turkish Journal of Medical Sciences / 1998 / Cilt: 28 - Sayı: 2

Transvaginal Color Doppler Analysis of Benign Uterine Leiomyomas

Pages
179–181
Publication Date
2022-11-04
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

These values were significantly high in control group (p

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, the blood flow velocity waveforms of the leiomyoma, uterine artery and myometrium with color doppler ultrasound were analyzed in patients with postoperative diagnosis of benign uterine leiomyomas and 15 healthy volunteers as a control group were enrolled into the study.
📊
Key Findings & Data:The lowest RI and PI values obtained from uterine leiomyomas were 0.39 and 0.93.
💡
Conclusion & Impact:These values were significantly high in control group (p
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Uterine · Leiomyoma · Ultrasonography

Abstract

In this study, the blood flow velocity waveforms of the leiomyoma, uterine artery and myometrium with color doppler ultrasound were analyzed in patients with postoperative diagnosis of benign uterine leiomyomas and 15 healthy volunteers as a control group were enrolled into the study. The lowest RI and PI values obtained from uterine leiomyomas were 0.39 and 0.93. Mean RI and PI values obtained from uterine leiomyomas were 0.39 and 0.93. Mean RI of mometrial blood flow was 0.57, while mean PI was 0.98. These measurements were done by using the color flows that were obtained from either center visualized and values of RI and PI were averaged both in myo-ma and control groups In patients with uterine leiomyomas mean RI and PI of uterine artery were 0.63 and 1.32 respectively. In control group mean RI was 0.82 and mean PI was 2.21. These values were significantly high in control group (p

Özet

In this study, the blood flow velocity waveforms of the leiomyoma, uterine artery and myometrium with color doppler ultrasound were analyzed in patients with postoperative diagnosis of benign uterine leiomyomas and 15 healthy volunteers as a control group were enrolled into the study. The lowest RI and PI values obtained from uterine leiomyomas were 0.39 and 0.93. Mean RI and PI values obtained from uterine leiomyomas were 0.39 and 0.93. Mean RI of mometrial blood flow was 0.57, while mean PI was 0.98. These measurements were done by using the color flows that were obtained from either center visualized and values of RI and PI were averaged both in myo-ma and control groups In patients with uterine leiomyomas mean RI and PI of uterine artery were 0.63 and 1.32 respectively. In control group mean RI was 0.82 and mean PI was 2.21. These values were significantly high in control group (p

🔖

Cite This Article

GÖKMEN, O., EKİCİ, E., ZORLU, C. G., IŞIK, A. Z., DANIŞMAN, N. (2022). Transvaginal Color Doppler Analysis of Benign Uterine Leiomyomas. Turkish Journal of Medical Sciences, Cilt: 28 - Sayı: 2, 179–181. https://ajindex.com/articles/612598

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...