Journals / Turkish Journal of Medical Sciences / 2016 / Cilt: 46 - Sayı: 1

The utility of EBUS-TBNA in mediastinal or hilar lymph node evaluation in extrapulmonary malignancy

Pages
112–119
Publication Date
2022-11-05
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The diagnostic sensitivity, accuracy, and negative predictive value of EBUSTBNA per patient were 78.2%, 91.8%, and 88.3%, respectively.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Background/aim: The aim of this study was to determine the diagnostic performance of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) in the diagnosis of mediastinal and hilar lymph nodes (LNs) in patients with known extrapulmonary malignancy.
📊
Key Findings & Data:Materials and methods: Between March 2011 and August 2013, 378 EBUS-TBNA procedures were performed.
💡
Conclusion & Impact:The diagnostic sensitivity, accuracy, and negative predictive value of EBUSTBNA per patient were 78.2%, 91.8%, and 88.3%, respectively.
🔬Design:Research Article
📍Scope:2011 Verileri
⚙️Variables:Domain Parameters

Abstract

Background/aim: The aim of this study was to determine the diagnostic performance of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) in the diagnosis of mediastinal and hilar lymph nodes (LNs) in patients with known extrapulmonary malignancy. Materials and methods: Between March 2011 and August 2013, 378 EBUS-TBNA procedures were performed. Sixty-three (16.6%) of these were performed on known extrapulmonary malignancy patients. Results: There were 28 male and 35 female patients, with median ages of 65 years (min max: 53 87) and 57 years (min max: 39 76), respectively. From the 63 cases, 138 lymph nodes (LNs) were sampled with EBUS-TBNA (median: 2 LNs/patient; min max: 1 4). Results of EBUS-TBNA revealed malignancy in 18 (28.5%) and nonmalignancy in 45 (71.5%). In the nonmalignant group, there were false negatives in 5 (7.9%), anthracosis in 13 (20.6%), reactive adenitis in 16 (25.3%), sarcoidosis in 7 (11.1%), and tuberculosis in 2 (3.1%), and 2 were not evaluated (lost to follow-up) (3.1%). The diagnostic sensitivity, accuracy, and negative predictive value of EBUSTBNA per patient were 78.2%, 91.8%, and 88.3%, respectively.

🔖

Cite This Article

EROL, S., ÖZKAN, S., ANAR, C. M., ERER, O. F. (2022). The utility of EBUS-TBNA in mediastinal or hilar lymph node evaluation in extrapulmonary malignancy. Turkish Journal of Medical Sciences, Cilt: 46 - Sayı: 1, 112–119. https://ajindex.com/articles/610690

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. Gu P, Zhao YZ, Jiang LY, Zhang W, Xin Y, Han BH. Endobronchial ultrasound-guided transbronchial needle aspiration for staging of lung cancer: a systematic review and meta-analysis. Eur J Cancer 2009; 45: 1389–1396
  2. Lee HS, Lee GK, Lee HS, Kim MS, Lee JM, Kim HY, Nam BH, Zo JI, Hwangbo B. Real-time endobronchial ultrasoundguided transbronchial needle aspiration in mediastinal staging of non-small cell lung cancer: how many aspirations per target lymph node station? Chest 2008; 134: 368–374
  3. Yasufuku K, Nakajima T, Motoori K, Sekine Y, Shibuya K, Hiroshima K, Fujisawa T. Comparison of endobronchial ultrasound, positron emission tomography, and CT for lymph node staging of lung cancer. Chest 2006; 130: 710–718
  4. Detterbeck FC, Jantz MA, Wallace M, Vansteenkiste J, Silvestri GA. Invasive mediastinal staging of lung cancer: ACCP evidence based clinical practice guidelines (2nd edition). Chest 2007; 132: 202S–220S
  5. Cameron SE, Andrade RS, Pambuccian SE. Endobronchial ultrasound-guided transbronchial needle aspiration cytology: a state of the art review. Cytopathology 2010; 21: 6–26
  6. Chong S, Lee KS, Chung MJ, Han J, Kwon OJ, Kim TS. Pneumoconiosis: comparison of imaging and pathologic findings. Radiographics 2006; 26: 59–77
  7. De Leyn P, Dooms C, Kuzdzal J, Lardinois D, Passlick B, RamiPorta R, Turna A, Schil PV, Venuta F, Waller D et al. Revised ESTS guidelines for preoperative mediastinal lymph node staging for non-small-cell lung cancer. Eur J Cardiothorac Surg 2014; 45: 787–798
  8. Tremblay A, Stather DR, Maceachern P, Khalil M, Field SK. A randomized controlled trial of standard vs endobronchial ultrasonography-guided transbronchial needle aspiration in patients with suspected sarcoidosis. Chest 2009; 136: 340–346
  9. Nakajima T, Yasufuku K, Kurosu K, Takiguchi Y, Fujiwara T, Chiyo M, Shibuya K, Hiroshima K, Nakatani Y, Yoshino I. The role of EBUS–TBNA for the diagnosis of sarcoidosis comparisons with other bronchoscopic diagnostic modalities. Respir Med 2009; 103: 1796–1800
  10. Hong G, Lee KJ, Jeon K, Koh WJ, Suh GY, Chung MP, Kim H, Kwon OJ, Han J, Um SW. Usefulness of endobronchial ultrasound-guided transbronchial needle aspiration for diagnosis of sarcoidosis. Yonsei Med J 2013; 54: 1416–1421
  11. Sun J, Teng J, Yang H, Li Z, Zhang J, Zhao H, Garfield DH, Han B. Endobronchial ultrasound-guided transbronchial needle aspiration in diagnosing intrathoracic tuberculosis. Ann Thorac Surg 2013; 96: 2021–2027
  12. Ren S, Zhang Z, Jiang H, Wu