Journals / Turkish Journal of Medical Sciences / 2019 / Cilt: 49 - Sayı: 5

Is the version angle of the glenoid different in bone and cartilage? An MRI study

Pages
1317–1323
Publication Date
2022-11-05
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Therefore, in the preoperativeplanning and evaluation of glenoid-based pathologies, it would be more appropriate to evaluate both the bone and cartilage surface onMRI.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Background/aim: To determine whether or not there is a difference between the version of the bone and cartilage surfaces of theglenoid.
📊
Key Findings & Data:Axial magnetic resonance imaging (MRI) slices were examined in order to evaluate the measurements taken based on both thecartilage and bone joint surfaces.Materials and methods: A retrospective evaluation was made of the MRI scans of 182 patients.
💡
Conclusion & Impact:Therefore, in the preoperativeplanning and evaluation of glenoid-based pathologies, it would be more appropriate to evaluate both the bone and cartilage surface onMRI.
🔬Design:Review & Systematic Survey
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Background/aim: To determine whether or not there is a difference between the version of the bone and cartilage surfaces of theglenoid. Axial magnetic resonance imaging (MRI) slices were examined in order to evaluate the measurements taken based on both thecartilage and bone joint surfaces.Materials and methods: A retrospective evaluation was made of the MRI scans of 182 patients. All of the reviewers independentlymeasured the glenoid version angles of all of the patients from 1–182. The process was then repeated, with each reviewer takingsecond measurements of the angles from 1–182. Pearson correlation coefficient analysis was applied to evaluate the interactionand relationships between the measurements taken from the bone and cartilage. The intra- and interobserver interclass correlationcoefficients (ICCs) were assessed. Analysis of variance was applied to determine any interobserver significant differences.Results: The mean glenoid version was determined as –3.58 ± 4.08° in the bone-based measurements and –5.81 ± 4.30° in the cartilagebased measurements. The cartilage- and bone-based measurements were found to have inter- and intraobserver reliability. A statisticallysignificant difference was observed between the mean cartilage-based version and the mean bone-based version. Changes in thecartilage- and bone-based measurements were correlated; however, this change was not linear.Conclusion: The cartilage-based version showed a significant difference from the bone- based version. Therefore, in the preoperativeplanning and evaluation of glenoid-based pathologies, it would be more appropriate to evaluate both the bone and cartilage surface onMRI.

🔖

Cite This Article

KULAKOĞLU, B., DEVECİ, A., CEYHAN, E., KILIÇ, E., DURA, Y. C., TURAN, S., ÖZDEMİR, G., CILIZ, D. S. (2022). Is the version angle of the glenoid different in bone and cartilage? An MRI study. Turkish Journal of Medical Sciences, Cilt: 49 - Sayı: 5, 1317–1323. https://ajindex.com/articles/610123

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Hoenecke HR, Hermida JC, Flores-Hernandez C, D’Lima DD. Accuracy of CT-based measurements of glenoid version for total shoulder arthroplasty. Journal of Shoulder and Elbow Surgery 2010; 19 (2): 166-171
  2. Van de Bunt F, Pearl ML, Lee EK, Peng L, Didomenico P. Glenoid version by CT scan: an analysis of clinical measurement error and introduction of a protocol to reduce variability. Skeletal Radiology 2015; 44 (11): 1627-1635
  3. Zale CL, Pace GI, Lewis GS, Chan J, Kim HM. Interdepartmental imaging protocol for clinically based three-dimensional computed tomography can provide accurate measurement of glenoid version. Journal of Shoulder and Elbow Surgery 2018; 27 (7): 1297-1305
  4. Churchill RS, Brems JJ, Helmuth Kotschi H. Glenoid size, inclination, and version: an anatomic study. Journal of Shoulder and Elbow Surgery 2001; 10 (4): 327-332
  5. Daggett M, Werner B, Collin P, Gauci MO, Chaoui J et al. Correlation between glenoid inclination and critical shoulder angle: a radiographic and computed tomography study. Journal of Shoulder and Elbow Surgery 2015; 24 (12): 1948-1953
  6. Frankle MA, Teramoto A, Luo ZP, Levy JC, Pupello D. Glenoid morphology in reverse shoulder arthroplasty: classification and surgical implications. Journal of Shoulder and Elbow Surgery 2009; 18 (6): 874-85
  7. Fulin P, Kysilko M, Pokorny D, Padr R, Kasprikova N et al. Study of the variability of scapular inclination and the glenoid version - considerations for preoperative planning: clinicalradiological study. BMC Musculoskeletal Disorders 2017; 18 (1): 16. doi: 10.1186/s12891-016-1381-84 8. Lewis GS, Armstrong AD. Glenoid spherical orientation and version. Journal of Shoulder and Elbow Surgery 2011; 20 (1): 3-11
  8. Piponov HI, Savin D, Shah N, Domenic Esposito D, Schwartz B et al. Glenoid version and size: does gender, ethnicity, or body size play a role? International Orthopaedics 2016; 40 (11): 2347-2353
  9. Staeubli HU, Bosshard C, Porcellini P, Rauschning W. Magnetic resonance imaging for articular cartilage: cartilage-bone mismatch. Clinics in Sports Medicine 2002; 21(3): 417-433
  10. Friedman RJ, Hawthorne KB, Genez BM. The use of computerized tomography in the measurement of glenoid version. Journal of Bone and Joint Surgery-American Volume 1992; 74 (7): 1032-37
  11. Brewer B, Wubben R, Carrera G. Excessive retroversion of the glenoid cavity. A cause of non-traumatic posterior instability of the shoulder. Journal of Bone and Joint Surgery-American Volume 1986; 68 (5): 7