Journals / Turkish Journal of Chemistry / 2016 / Cilt: 40 - Sayı: 1

Square wave voltammetric determination of valproic acid in pharmaceuticalPreparations

Pages
106–116
Publication Date
2022-11-05
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Recovery studies for the accuracy of the method were performed byadding known amounts of VAL and it was found to be 109.67 4.85%.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The electrochemical behavior of valproic acid (VAL) was investigated using square wave voltammetry, cyclicvoltammetry, and sampled direct current polarography and a new square wave voltammetric method was developed fordetermination of VAL in pharmaceutical preparations.
📊
Key Findings & Data:VAL showed two reduction peaks at about {0.2 V and {0.8 V vs.Ag/AgCl 3 M KCl with a hanging mercury drop electrode in 0.05 M pH 3.3 Britton{Robinson (BR) buffer.
💡
Conclusion & Impact:Recovery studies for the accuracy of the method were performed byadding known amounts of VAL and it was found to be 109.67 4.85%.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

The electrochemical behavior of valproic acid (VAL) was investigated using square wave voltammetry, cyclicvoltammetry, and sampled direct current polarography and a new square wave voltammetric method was developed fordetermination of VAL in pharmaceutical preparations. VAL showed two reduction peaks at about {0.2 V and {0.8 V vs.Ag/AgCl 3 M KCl with a hanging mercury drop electrode in 0.05 M pH 3.3 Britton{Robinson (BR) buffer. These peakswere named peak I and peak II, respectively. The types of limiting current of both peaks were determined as diffusioncontrolled based on cyclic voltammetry studies. A linear calibration graph was obtained in the range 1.46 104{1.0 103M. The limit of detection (LOD) and limit of quanti cation (LOQ) were 1.09 104M (21.05 g/mL) and1.10 104M (144.20 g/mL), respectively. Recovery studies for the accuracy of the method were performed byadding known amounts of VAL and it was found to be 109.67 4.85%. The proposed method was successfully appliedto pharmaceutical products on the market.

🔖

Cite This Article

ACAR, E. T., ONAR, A. N. (2022). Square wave voltammetric determination of valproic acid in pharmaceuticalPreparations. Turkish Journal of Chemistry, Cilt: 40 - Sayı: 1, 106–116. https://ajindex.com/articles/601966

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. Darlington, D. N.; Gonzales, M. D.J. Liq. Chromatogr. R. T.2013,36, 2209{2219. 2.Kiencke, V.; Streichert, H. A.; Muller, A.; Bergmann, S. I.Int. J. Legal. Med.2013,127, 1101{1107. 3.Krogh, M.; Johansen, K.; T nnesen, F.; Rasmussen, K. E.J. Chromatogr. B.1995,673, 299{305. 4.Hara, S.; Kamura, M.; Inoue, K.; Fukuzawa, M.; Ono, M.; Kuroda, T.Biol. Pharm. Bull.1999,22, 975{977. 5.Chesler, M.Physiol. Rev.2003,83, 1183{1221. 6.Ogungbenro, K.; Aarons, L.Eur. J. Pharm. Sci.2014,63, 45{52. 7.Lagace, D. C.; O'Brien, T.; Gurvich, N.; Nachtigal, M. W.; Klein, P. S.Clin. Neurosci. Res.2004,4, 215{225. 8.Rhoden, L.; Antunes, M. V.; Hidalgo, P.; Silva, C. A.; Linden, R.J. Pharmaceut. Biomed.2014,96, 207{212. 9.Nakajima, M.; Yamato, S.; Shimada, K.; Sato, S.; Kitagawa, S.; Honda, A.; Miyamoto, J.; Shoda, J.; Ohya, M.;Miyazaki, H.Ther. Drug Monit.2000,22, 716{722. 10.Correman, S.; Cuypers, E.; Doncker, M. D.; Van Hee, P.; Uyttenbroeck, W.; Neels, H.Immuno-Anal. Biol. Spe.2008,23, 240{244. 11.Shahdousti, P.; Mohammadi, A.; Alizadeh, N.J. Chromatogr. B.2007,850, 128{133. 12.Matin, A. A.; Biparva, P.; Amanzadeh, H.; Farhadi, K.Talanta2013,103, 207{213. 13.Campos, F. F.; Calpena, A.; Soy, D.; Colom, H.J. Liq. Chromatogr. R. T.2012,35, 1171{1183. 14.Gao, S.; Miao, H.; Tao, X.; Jiang, B.; Xiao, Y.; Cai, F.; Yun, Y.; Li, J.J. Chromatogr. B.2011,879, 1939{1944. 15.Jain, D. S.; Subbaiah, G.; Sanyal, M.; Shrivastas, P.Talanta2007,72, 80{88. 16.Cheng, H.; Liu, Z.; Blum, W.; Byrd, J. C.; Klisovic, R.; Grever, M. R.; Marcucci, G.; Chan, K. K.J. Chromatogr.B.2007,850, 206{212. 17.Vancea, S.; Imre, S.; Vari, C.; Dogaru, M. T.; Muntean, D. L.; Caldararu, C.; Dogaru, G., Donath-Nagy, G.ActaMedica Marisiensis2012,58, 57{61. 18.Sorouraddin, M. H.; Nabiyyi, A. I.; Gehraz, S. A. N.; Rashidi, M. R.J. Lumin.2014,145, 253{258. 19.Bousquet, E.; Cavrini, V.; Gatti, R.; Spadar, A.J. Liq. Chromatogr. R. T.1998,21, 2873{2886. 20.Proenca, P.; Franco, J. M.; Mustra, C.; Marcos, M.; Pereira, A. R.; Corte-Real, F.; Vieira, D. N.J. Forensic. LegalMed.2011,18, 320{324. 21.Pham, T. T. T.; See, H. H.; Morand, R.; Krahenbuhl, S.J. Chromatogr. B.2012,907, 74{78. 22.Belin, G. K.; Krahenbuhl, S.; Hauser, P. C.J. Chromatogr. B.2007,847, 205{209. 23.Sava, M.; Chiriac, V. A.; Vlascic, D.Annals of West University of Timisoara, Series of Chemistry,2010,19,91{96. 24.Huang, L. S.; Gunawan, C.; Yen, Y. K.; Chang, K. F.Biosensors2015,5, 37{50. 25.Uslu, B.;Ozkan, S. A.Electrochim. Acta2004,49, 4321{4329. 26.Gupt