Journals / Turkish Journal of Chemistry / 2018 / Cilt: 42 - Sayı: 3

An ionic liquid/bismuth film-mo dified sensor for the electro chemical detection of cefixime

Pages
826–838
Publication Date
2022-11-05
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

These results showed that this simple analytical method can findpotential application in the clinical field instead of highly expensive and time-consuming processes

📌 3 Key Takeaways

🎯
Objective & Hypothesis:A highly sensitive and simple method based on an ionic liquid/ex situ bismuth film-modified single-use pencilgraphite electrode (IL/Bi/PGE) was offered for the electrochemical detection of cefixime (CEF) for the first time.
📊
Key Findings & Data:Anodic oxidation of CEF was observed at 0.9 V vs.
💡
Conclusion & Impact:These results showed that this simple analytical method can findpotential application in the clinical field instead of highly expensive and time-consuming processes
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

A highly sensitive and simple method based on an ionic liquid/ex situ bismuth film-modified single-use pencilgraphite electrode (IL/Bi/PGE) was offered for the electrochemical detection of cefixime (CEF) for the first time. Thesynergistic effects of the ionic liquid and bismuth film combination as the surface modifier remarkably improved theelectrochemical response of the modified sensor. Anodic oxidation of CEF was observed at 0.9 V vs. Ag/AgCl/3 MKCl as one well-defined irreversible oxidation peak. Under optimum experimental conditions, the IL/Bi/PGE exhibiteda linear relationship for CEF concentrations in the range of 0.005–0.5 µ M (R 2 = 0.996) with a detection limit as 0.22nM with square wave voltammetry. The IL/Bi/PGE had excellent sensor properties to electrochemically detect CEFwhen compared to the literature. This method was successfully applied for practical use with pharmaceutical samplesby standard addition method with high accuracy. These results showed that this simple analytical method can findpotential application in the clinical field instead of highly expensive and time-consuming processes

🔖

Cite This Article

YAMAN, Y. T., YARDIMCI, C., BOLAT, G., ABACI, S. (2022). An ionic liquid/bismuth film-mo dified sensor for the electro chemical detection of cefixime. Turkish Journal of Chemistry, Cilt: 42 - Sayı: 3, 826–838. https://ajindex.com/articles/601776

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (29)

  1. Brittain, D. C.; Scully, B. E.; McElrath, M. J.; Steinman, R.; Labthavikul, P.; Neu, H. C. J. Clin. Pharmacol. 1985, 25, 82-88
  2. Brogden, R. N.; Campoli-Richards, D. M. Drugs 1989, 38, 524-550
  3. Al-Momani, I. J. Pharm. Biomed. Anal. 2001, 25, 751-757
  4. Najmul, S.; Azmi, H.; Iqbal, B.; Said, N.; Al-Humaimi, H. J. Pharm. Anal. 2012, 3, 1-9
  5. Bebawy, L. I., El Kelani, K.; Fattah, L. A. J. Pharm. Biomed. Anal. 2003, 32, 1219-1225
  6. Shah, J.; Rasul Jan, M.; Tasmia, Yousaf, M. J. Appl. Spectrosc. 2016, 83, 248-253
  7. Honda, S.; Taga, A.; Kakehi, K.; Koda, S.; Okamoto, Y. J. Chromatogr. A 1992, 590, 364-368
  8. White, L. O.; Reeves, D. S.; Lovering, A. M.; MacGowan, A. P. J. Antimicrob. Chemother. 1992, 31, 450-450
  9. Gonz´alez-Hern´andez, R.; Nuevas-Paz, L.; Soto-Mulet, L.; L´opez-L´opez, M.; Hoogmartens, J. J. Liq. Chromatogr. Relat. Technol. 2001, 24, 2315-2324
  10. Meng, F.; Chen, X.; Zeng, Y.; Zhong, D. J. Chromatogr. B Anal. Technol. Biomed. Life Sci. 2005, 819, 277-282
  11. Madhusudana Reddy, T.; Sreedhar, M.; Jayarama Reddy, S. J. Pharm. Biomed. Anal. 2003, 31, 811-818
  12. Afkhami, A.; Soltani-Felehgari, F.; Madrakian, T. Electrochim. Acta 2013, 103, 125-133
  13. Golcu, A.; Dogan, B.; Ozkan, S. Talanta 2005, 67, 703-712
  14. Ensafi, A.; Allafchian, A. R. Colloid. Surface. B 2013, 102, 687-693
  15. Karimian, N.; Gholivand, M. B.; Malekzadeh, G. J. Electroanal. Chem. 2016, 771, 64-72
  16. Asadollahi-Baboli, M.; Mani-Varnosfaderani, A. Measurement 2014, 47, 145-149
  17. Wang, J.; Kawde, N.; Sahlin, E. Analyst 2000, 125, 5-7
  18. Gao, W.; Song, J.; Wu, N. J. Electroanal. Chem. 2005, 576, 1-7
  19. Jadon, N.; Jain, R.; Pandey, A. J. Electroanal. Chem. 2017, 788, 7-13
  20. Fard, G. P.; Alipour, E.; Sabzi, R. E. A. Anal. Methods 2016, 8, 3966-3974
  21. Dilgin, D. G.; Karakaya, S. Mater. Sci. Eng. C 2016, 63, 570-576
  22. Dede, E.; Saglam, O.; Dilgin, Y. Electrochim. Acta 2014, 127, 20-26
  23. Prasad, B. B.; Fatma, S. Electrochim. Acta 2017, 232, 474-483
  24. David, I. G.; Popa, D. E.; Calin, A. A.; Buleandra, M.; Iorgulescu, E. E. Turk. J. Chem. 2016, 40, 125-135
  25. Altay, C.; Eksin, E.; Congur, G.; Erdem, A. Talanta 2015, 144, 809-815
  26. Economou, A. TrAC-Trend. Anal. Chem. 2005, 24, 334-340
  27. Gonzalo, V. P. B.; Borgnino, L.; Ortiz, P. I. Sens. Actuators B Chem. 2014, 203, 396-405
  28. Sopha, H.; Hocevar, S. B.; Pihlar, B.; Ogorevc, B. Electrochim. Acta 2012, 60, 274-277
  29. Svancara, I.; Prior, C.; Hoˇcevar, S. B.; Wang, J.ˇ Electroanaly