Journals / Turkish Journal of Chemistry / 2020 / Cilt: 44 - Sayı: 5

Determination of blood glucose parameter from human blood serum by using a quartz crystal microbalance sensor coated with phthalocyanines compounds

Pages
1293–1302
Publication Date
2022-11-01
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

As a result of the study, human glucose values were determined with an average error of 3.25%.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Determining the blood glucose level is important for the prevention and treatment of diabetes mellitus.
📊
Key Findings & Data:In the first stage of the study, the QCM sensor with the highest performance was identified using artificial glucose solution concentrations.
💡
Conclusion & Impact:As a result of the study, human glucose values were determined with an average error of 3.25%.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Determining the blood glucose level is important for the prevention and treatment of diabetes mellitus. We developed a sensor system using Quartz Crystal Microbalance (QCM) to determine the blood glucose level from human blood serum. This study consists of two experimental stages: artificial glucose/pure water solution tests and human blood serum tests. In the first stage of the study, the QCM sensor with the highest performance was identified using artificial glucose solution concentrations. In the second stage of the study, human blood serum measurements were performed using QCM to determine blood glucose levels. QCM sensors were coated with phthalocyanines (Pcs) by jet spray method. The blood glucose values of 96 volunteers, which ranged from 71 mg/dL to 329 mg/dL, were recorded. As a result of the study, human glucose values were determined with an average error of 3.25%.

🔖

Cite This Article

KOÇAK, F. E., SADIK, E. Ş., GÜROL, İ., EBEOĞLU, M. A., SARAOĞLU, H. M. (2022). Determination of blood glucose parameter from human blood serum by using a quartz crystal microbalance sensor coated with phthalocyanines compounds. Turkish Journal of Chemistry, Cilt: 44 - Sayı: 5, 1293–1302. https://ajindex.com/articles/601610

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Da Rocha Fernandes J, Ogurtsova K, Linnenkamp U, Guariguata L, Seuring T et al. IDF Diabetes Atlas estimates of 2014 global health expenditures on diabetes. Diabetes Research and Clinical Practice 2016
  2. doi: 10.1016/j.diabres.2016.04.016 2. King WH. Piezoelectric sorption detector. Analytical Chemistry 1964
  3. 36 (9): 1735-1739. doi: 10.1021/ac60215a012 3. Konash PL, Bastiaans GJ. Piezoelectric crystals as detectors in liquid chromatography. Analytical Chemistry 1980
  4. 52 (12): 1929-1931. doi: 10.1021/ac50062a033 4. Kanazawa KK, Gordon JG. Frequency of a quartz microbalance in contact with liquid. Analytical Chemistry 1985
  5. 57 (8): 1770-1771. doi: 10.1021/ac00285a062 5. Kanazawa KK, Gordon JG. The oscillation frequency of a quartz resonator in contact with liquid. Analytica Chimica Acta 1985
  6. doi: 10.1016/S0003-2670(00)82721-X 6. Martin SJ, Granstaff VE, Frye GC. Characterization of a quartz crystal microbalance with simultaneous mass and liquid loading. Analytical Chemistry 1991
  7. 63 (20): 2272-2281. doi: 10.1021/ac00020a015 7. Cheng TJ, Lin TM, Wu TH, Chang HC. Determination of heparin levels in blood with activated partial thromboplastin time by a piezoelectric quartz crystal sensor. Analytica Chimica Acta 2001
  8. 432 (1): 101-111. doi: 10.1016/S0003-2670(00)01346-5 8. Huang H, Zhou J, Chen S, Zeng L, Huang Y. A highly sensitive QCM sensor coated with Ag+-ZSM-5 film for medical diagnosis. Sensors and Actuators B: Chemical 2004
  9. 101 (3): 316-321. doi: 10.1016/j.snb.2004.04.001 9. Lin TY, Hu CH, Chou TC. Determination of albumin concentration by MIP-QCM sensor. Biosensors and Bioelectronics 2004
  10. 20 (1): 75-81. doi: 10.1016/j.bios.2004.01.028 10. Saraoglu HM, Kocan M. Determination of blood glucose level-based breath analysis by a quartz crystal microbalance sensor array. IEEE Sensors Journal 2010
  11. 10 (1): 104-109. doi: 10.1109/JSEN.2009.2035769 11. Muller L, Sinn S, Drechsel H, Ziegler C, Wendel HP et al. Investigation of prothrombin time in human whole-blood samples with a quartz crystal biosensor. Analytical Chemistry 2010
  12. 82 (2): 658-663. doi: 10.1021/ac9021117 12. Erbahar DD, Harbeck M, Gumus G, Gurol I, Ahsen V. Self-assembly of phthalocyanines on quartz crystal microbalances for QCM liquid sensing applications. Sensors and Actuators B: Chemical 2014
  13. doi: 10.1016/j.snb.2013.09.034 13. Tasaltin C, Gurol I, Harbeck M, Musluoglu E, Ahsen V et al. Synthesis and DMMP sensing properties of fluoroalkyloxy and fluoroar