Journals / Mühendislik Bilimleri Dergisi / 2001 / Cilt: 7 - Sayı: 2

Tıbbi uygulamalar için boru şeklindeki saç örgülerinin elastik deformasyonunun incelenmesi

Analysis of elastic deformation of braided tubular structures for medical applications

Pages
277–285
Publication Date
2022-10-18
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Therefore, the geometry of the three dimensional tubular braided fabric is analyzed to give an optimum radial force for medical applications.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, self-expanding stents were fabricated and analyzed.
📊
Key Findings & Data:These stents are in the form of 3-D tubular braided structures made of polymeric materials.
💡
Conclusion & Impact:Therefore, the geometry of the three dimensional tubular braided fabric is analyzed to give an optimum radial force for medical applications.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

In this study, self-expanding stents were fabricated and analyzed. These stents are in the form of 3-D tubular braided structures made of polymeric materials. This type of structures is used in medicine to open clogged artheries and veins by exerting radial force. The amount of radial force exerted into the membrane should not give any damage to the veins. Therefore, the geometry of the three dimensional tubular braided fabric is analyzed to give an optimum radial force for medical applications.

Özet

Bu çalışmada kendinden uzamalı katedırlar üretilip analiz edilmiştir. Katedırlar üç boyutlu saç örgüsü yapısında olup, polimer yada metal malzemeden imal edilirler. Bu tip yapılar tıbbi alanda tıkanmış olan atardamarların açılmasında merkezden dışa doğru bir kuvvet uygulanması prensibine göre kullanılır. Katedır tarafından damar çeperlerine uygulanan kuvvetin damarlara bir zarar vermeyecek miktarda olması zaruridir. Bundan dolayı, bu tür üç boyutlu hortumsal saç örgülerin yapısı tıbbi uygulamalar için optimum radial kuvvet elde edilebilmesi için incelenmiştir.

🔖

Cite This Article

YÜKSEKKAYA, M. E. (2022). Tıbbi uygulamalar için boru şeklindeki saç örgülerinin elastik deformasyonunun incelenmesi. Mühendislik Bilimleri Dergisi, Cilt: 7 - Sayı: 2, 277–285. https://ajindex.com/articles/583354

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (7)

  1. Anonymous, 1993. American Society for Testing and Materials (ASTM). Standard Test Methods for Tension and Elongation of Elastic Fabrics (Constant Rate-of-Extension Type Tensile Testing Machine), ASTM Designation D4964 in ASTM Book of Standards, Section 7, Vol. 07.02, Philadelphia, Pennsylvania, ASTM. Dieter, G. E. 1976. Mechanical Metallurgy, 2nd Edition Tokyo: McGraw-Hill. Du, G. W. and Popper, P. 1990.
  2. Process Model of Circular Braiding, Processing of Polymers and Polymeric Composites, ASME, 19, 119-125.
  3. Gere, J. M. and Timoshenko, S. 1984. Mechanics of Materials, 2nd Edition,
  4. PWS Engineering, Boston, Massachusetts. Goff, J. M. 1976. The Geometry of Tubular Braided Structures, Master Thesis, Georgia Institute of Technology, Atlanta, Georgia. Jedwab, M. R., and Clerc, C. O. 1992. A Study of the Geometrical and Mechanical Properties of a Self-Expanding Metallic Stent-Theory and Experiment, Journal of Applied Biomaterials, (4), 77-85.
  5. Ko, F. K., Pastore, C. M., and Head, A. A. 1976.
  6. Handbook of Industrial Braiding, Atkins & Pearce. Montgomery, D. C. 1991. Design and Analysis of Experiments, 3rd Edition, John Wiley & Sons, New York, New York. Paris, E., King, M. W., Guidoin, R. G., Delermo, J., Deng, X., and Douville, Y. 1994. Innovations and Deviations in Therapeutic Vascular Devices, Polymeric Biomaterials, Marcel Dekker, Inc, New York, New York, 245-275.
  7. Schmitt, P. J. 1992. A Radially Self-Expanding Implantable Intraluminal Device, US Patent No: PCT/US93/08649. Wahl, A. M. 1963. Mechanical Spring, 2nd Edition New York, New York.