Journals / Joint diseases and related surgery / 2020 / Cilt: 31 - Sayı: 2

Do three-dimensional modeling and printing technologies have an impact on the surgical success of percutaneous transsacral screw fixation?

Pages
273–280
Publication Date
2022-10-19
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The amount of deviation from the ideal wire entry site was significantly reduced in the template group compared to the conventional method group (p=0.001).Conclusion: With the use of 3D modeling and printing technology, CT-derived templates can be produced and utilized for transsacral screw fixation procedures and their use increases surgical success by reducing the surgical margin of error.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objectives: This study aims to determine the role of computed tomography (CT)-derived templates, produced by three-dimensional (3D) modeling, image processing and printing technology, in percutaneous transsacral screw fixation and evaluate the effects of their use on surgical success.Materials and methods: This prospective study conducted between June 2018 and December 2019 utilized 15 composite pelvis models for transsacral-transiliac screw fixation.
📊
Key Findings & Data:In the computed tomography images acquired after wiring, appropriate wire position was evaluated.Results: The placed wires held the S1 body appropriately in all of the procedures with or without template use.
💡
Conclusion & Impact:The amount of deviation from the ideal wire entry site was significantly reduced in the template group compared to the conventional method group (p=0.001).Conclusion: With the use of 3D modeling and printing technology, CT-derived templates can be produced and utilized for transsacral screw fixation procedures and their use increases surgical success by reducing the surgical margin of error.
🔬Design:Modeling & Simulation
📍Scope:2018 Verileri
⚙️Variables:Domain Parameters

Abstract

Objectives: This study aims to determine the role of computed tomography (CT)-derived templates, produced by three-dimensional (3D) modeling, image processing and printing technology, in percutaneous transsacral screw fixation and evaluate the effects of their use on surgical success.Materials and methods: This prospective study conducted between June 2018 and December 2019 utilized 15 composite pelvis models for transsacral-transiliac screw fixation. For the procedure, modeled templates were utilized for wiring on the left side of the pelvis models, while the conventional method was performed on the right side of the pelvis models. In the computed tomography images acquired after wiring, appropriate wire position was evaluated.Results: The placed wires held the S1 body appropriately in all of the procedures with or without template use. With the template use, the wires were placed appropriately in the surgical bone corridor suitable for the transsacral-transiliac screw fixation in all of the models. However, with the conventional methods, the wires were not placed in the safe surgical bone corridor in four models. The wire deviation angle in the axial plane was significantly lower in the template group (p=0.001), whereas it was not different between the template group and the conventional method group in the coronal plane (p=0.054). The amount of deviation from the ideal wire entry site was significantly reduced in the template group compared to the conventional method group (p=0.001).Conclusion: With the use of 3D modeling and printing technology, CT-derived templates can be produced and utilized for transsacral screw fixation procedures and their use increases surgical success by reducing the surgical margin of error.

🔖

Cite This Article

DURUSOY, S., PAKSOY, A. E., AKDOĞAN, V. (2022). Do three-dimensional modeling and printing technologies have an impact on the surgical success of percutaneous transsacral screw fixation?. Joint diseases and related surgery, Cilt: 31 - Sayı: 2, 273–280. https://ajindex.com/articles/559335

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Hermans E, Biert J, Edwards MJR. Epidemiology of Pelvic Ring Fractures in a Level 1 Trauma Center in the Netherlands. Hip Pelvis 2017;29:253-61
  2. Swaid F, Peleg K, Alfici R, Olsha O, Givon A, Kessel B, et al. A comparison study of pelvic fractures and associated abdominal injuries between pediatric and adult blunt trauma patients. J Pediatr Surg 2017;52:386-9
  3. Grotz MR, Allami MK, Harwood P, Pape HC, Krettek C, Giannoudis PV. Open pelvic fractures: epidemiology, current concepts of management and outcome. Injury 2005;36:1-13. 4. van den Bosch EW, van Zwienen CM, van Vugt AB. Fluoroscopic positioning of sacroiliac screws in 88 patients. J Trauma 2002;53:44-8
  4. Routt ML Jr, Kregor PJ, Simonian PT, Mayo KA. Early results of percutaneous iliosacral screws placed with the patient in the supine position. J Orthop Trauma 1995;9:207-14
  5. Tonetti J, Cazal C, Eid A, Badulescu A, Martinez T, Vouaillat H, et al. Neurological damage in pelvic injuries: a continuous prospective series of 50 pelvic injuries treated with an iliosacral lag screw. Rev Chir Orthop Reparatrice Appar Mot 2004;90:122-31
  6. Schweitzer D, Zylberberg A, Córdova M, Gonzalez J. Closed reduction and iliosacral percutaneous fixation of unstable pelvic ring fractures. Injury 2008;39:869-74
  7. Osterhoff G, Noser J, Sprengel K, Simmen HP, Werner CML. Rate of intraoperative problems during sacroiliac screw removal: expect the unexpected. BMC Surg 2019;19:39
  8. Lucas JF, Routt ML Jr, Eastman JG. A useful preoperative planning technique for transiliac-transsacral screws. J Orthop Trauma 2017;31:e25-e31
  9. Lindsay A, Tornetta P 3rd, Diwan A, Templeman D. Is closed reduction and percutaneous fixation of unstable posterior ring injuries as accurate as open reduction and internal fixation? J Orthop Trauma 2016;30:29-33
  10. Durusoy S, Paksoy AE, Korkmaz M, Solak AŞ, Dağlar B. Is pelvic mapping applicable in iliosacral screw fixation to determine screw entry point and screw trajectory? Eklem Hastalik Cerrahisi 2019;30:252-8
  11. Tidwell J, Cho R, Reid JS, Boateng H, Copeland C, Sirlin E. Percutaneous Sacroiliac Screw Technique. J Orthop Trauma 2016;30:S19-20
  12. Gardner MJ, Routt ML Jr. Transiliac-transsacral screws for posterior pelvic stabilization. J Orthop Trauma 2011;25:378-84
  13. Aprato A, Devivo S, Masse A. Ten tips to improve iliosacral screw placement. J Clin Exp Orthop 2018;4:59
  14. Routt ML Jr, Simonian PT, Mills WJ. Iliosacral screw fixation: early complications of the percutaneou