Journals / Jinekoloji-Obstetrik ve Neonatoloji Tıp Dergisi / 2012 / Cilt: 9 - Sayı: 33

URETHRAL CATHETERISATION WITH ABDOMINAL ULTRASOUND IN THE MEASUREMENT OF RESIDUAL URINE VOLUME AFTER ANTI- INCONTINENCE OPERATIO

ANTİ-İNKONTİNANS OPERASYONLARI SONRASI REZİDÜEL İDRAR VOLÜMÜ ÖLÇÜMÜNDE ÜRETRAL KATETERİZASYON İLE ABDOMİNAL ULTRASONOGRAFİNİN KARŞILAŞTIRILMASI

Pages
1354–1357
Publication Date
2022-10-18
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Transabdominal ultrasonograhy is an alternative method to measurement by catheter.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Aim: In this study the accuracy of transabdominal ultrasonography in measuring residual urine volume after anti-incontinence operation was investigated.
📊
Key Findings & Data:Material and Methods: Total 74 patients were evaluated between May 2010 and July 2011.
💡
Conclusion & Impact:Transabdominal ultrasonograhy is an alternative method to measurement by catheter.
🔬Design:Research Article
📍Scope:2010 Verileri
⚙️Variables:Rezidü idrar · urethra kateterizazasyonu · transabdominal sonografi

Abstract

Aim: In this study the accuracy of transabdominal ultrasonography in measuring residual urine volume after anti-incontinence operation was investigated. Material and Methods: Total 74 patients were evaluated between May 2010 and July 2011. Bladder volümes were calculated using three different formulas by the same doctor and ultrasonography, were compared with the values obtained by urethral catheterisation. Results: A good correlation was found between the results of catheter and each of three formulas R1= 0.962, R2= 0.974, 0.986 by calculating with transabdominal ultrasonography. The mean measurement difference among groups were not statistically significant p = 0.451 . Conclusion: Transabdominal ultrasonography is a reliable method in measuring residual urine volume after anti-incontinence operation. The used three formu- las don’t have superiority or difference to each other. Transabdominal ultrasonograhy is an alternative method to measurement by catheter.

Özet

Amaç:Bu çalışmada anti-inkontinans ameliyatları sonrası rezidü idrar volümü hesaplanmasında transabdominal ultrasonografinin doğruluğu araştırıldı. Yöntem ve Gereçler: Mayıs 2010 ile Temmuz 2011 tarihleri arasında toplam 74 hasta çalışmaya dahil edilmiştir. Aynı doktor ve ultrason ile mesane volümleri 3 farklı formülle hesaplanıp, üretral kateterizasyonla elde edilen değerlerle karşılaştırıldı. Bulgular: Üretral kateter sonuçları ve transabdominal ultrasonografi eşliğinde her 3 formül ile hesaplanan sonuçlar arasında anlamlı bir ilişki saptandı R1= 0.962, R2= 0.974, R3= 0.986 . Ortalama ölçüm farkları gruplar arasında istatistiksel olarak anlamlı değildi p = 0.451 . Sonuç: Anti-inkontinans operasyonları sonrası rezidü idrar volümü ölçümünde transabdominal ultrasonografi güvenilir bir metodtur. Kullanılan her üç formülün birbirine üstünlüğü ve farkı yoktur. Transabdominal ult- rasonografi üretral kateterle ölçüme alternatif bir yöntemdir.

🔖

Cite This Article

ÖZAKŞİT, G., DOĞANAY, M., DUMANLI, H., AKSAKAL, O. (2022). URETHRAL CATHETERISATION WITH ABDOMINAL ULTRASOUND IN THE MEASUREMENT OF RESIDUAL URINE VOLUME AFTER ANTI- INCONTINENCE OPERATIO. Jinekoloji-Obstetrik ve Neonatoloji Tıp Dergisi, Cilt: 9 - Sayı: 33, 1354–1357. https://ajindex.com/articles/558974

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (1)

  1. Szabo V, Sobel M, Pajor L.Ultrasonic measurement of residual urine: A method requiring no catheter. Int Urol Nephrol. 1981; 13: 345 2.Smith DR. Estimation of theamount of residuelurine by means of phenosulphophthalcin test. J Urol. 1960; 83: 188-91. 3.Kalis E. Measurement of the volume of residual urine using 131 Hippuranand gamma camera. Br J Urol 1975; 47: 567-70. 4.Roehrborn C, et al. Diagnostic work-up of patients presentingwith symptoms suggestive of prostatism. In: The International Consultation on Benign Prostatic Hyperplasia. SCI, Paris,.1991; sayfa 93-136. 5.Aydın M, Güvendi A, Köse C ve ark. Rezidüel idrarın kantitatif tayini. Ultrasonografi ile mi yoksa kateterle mi? Türk Üroloji Dergisi. 1998; 24(1): 57-60. 6.Hartnell GG, Kiely EA, Williams G, et al: Real time ultrasound measurement of bladder volume: A comparative study of three methods. Br J Radiol. 1987; 60: 1063-65. 7.Hakanberg OW, Ryal RL, Langlois SL, et al: The estimation of bladder volume by sonocystography. J Urol 1983; 130: 249-51. 8.Poston GJ, Joseph AEA, Rieddle PR: The accuracy of ultrasound in the measurement of changes in bladder volume. Br J Urol 1983; 55: 361-63. 9.Griffiths CJ, Murray A, Ramsden PD: Accuracy and repeatability of bladder volume measurement using ultrasound imaging. J Urol 1986; 136: 808-12. 10.Dinçel Ç, Akbulut H, İslim F ve ark: Rezidüel idrar ölçümü: Transabdominal ultrasonografi ve üretral kateterizasyonun karşılaştırılması. Türk Üroloji Dergisi: 1999; 25(3): 314-18. 11.Thomas C, Mainpriza MD, Harold D: Accuracy of total bladder volume and residual urine measurements: Comparison between real time ultrasonography and catheterization. Am J Obstet Gynecol. 1989; 160: 1013-5. 12.Lertbunnaphong T,Inthasorn P, Boriboonhirunsam D, Chuchotirot M, Russameecharoen K, Phattanachindakun B. Transabdominal ultrasound in the assessment of postvoid residual urine volume in patients after hysterectomy. J Med Assoc Thai. 2006; 89 (4): 152-7. 13.Watanabe A, Ichimatsu K, Ito T, Morii A, Yasuda K, Fujiuchi Y, Mizuno I, Fuse H. The efficacy of portable 3-dimensional ultrasound scanning device (Bladder Scan BVI6100) for measurement of residual urine volume-comparison with transabdominal ultrasound estimation. Hinyokika Kiyo. 2008; 54(3): 203-6.