Journals / İnönü Üniversitesi Turgut Özal Tıp Merkezi Dergisi / 2013 / Cilt: 20 - Sayı: 4

Perkutan Koroner Girişim Komplikasyonu: Koroner Perforasyon

A Percutaneous Coronary Intervention Complication: Coronary Perforation

Pages
338–340
Publication Date
2022-10-17
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Bleeding control was achieved with implantation of 3,0>

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Coronary perforation is the most feared and lethal complication in the catheterization laboratories.
📊
Key Findings & Data:Perforation incidence is reported to be between 0,2 O,6%.
💡
Conclusion & Impact:Bleeding control was achieved with implantation of 3,0>
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Coronary perforation is the most feared and lethal complication in the catheterization laboratories. Perforation incidence is reported to be between 0,2 O,6%. Sixty nine year-old patient with typical angina pectoris and having positive effort test was admitted to the catheter laboratory for coronary angiography. In the coronary angiography, Biomime stent was deployed with nominal pressure to the mid segment of the left anterior descending (LAD) artery which was found to have 80% stenosis. In order to obtain optimal expansion, postdilatation was performed with powerline balloon. After postdilatation, Ellis grade III perforation was developed. Bleeding control was achieved with implantation of 3,0>

Özet

Koroner perforasyon, kateterizasyon laboratuvarının en korkulan ve ölümcül olabilen komplikasyonudur. Perforasyon sıklığı %O,2--O,6 olarak bildirilmiştir. Koroner perforasyonda, işlemi yapan kardiyologun kılavuzlarda bildirilen yetkinliğe sahip olması, kateter laboratuvarında covered stent bulunması hayat kurtarıcı olmaktadır. Efor testi pozitif olan, tipik anjina tanımlayan 69 yaşındaki hasta koroner anjiografi için kateter laboratuvarın alındı. Koroner anjiografide sol Ön inen koroner arter (LAD) orta segmentte saptanan %80 darlığa Biomime stent nominal basınçla yerleştirildi. Optimal açılımı sağlamak için powerline balon ile postdilatasyon uygulandı. Postdilatasyon sonucu Ellis grade lll perforasyon gelişti. Perforasyon bölgesine 3,0X'l9 mm graft stent implante edildi. Yapılan ekokardiyografi incelemelerinde perikardial mayii ve tamponat bulguları saptanmayan hasta stabil olarak taburcu edildi.

🔖

Cite This Article

BAĞIRTAN, B., YILDIZ, A. (2022). Perkutan Koroner Girişim Komplikasyonu: Koroner Perforasyon. İnönü Üniversitesi Turgut Özal Tıp Merkezi Dergisi, Cilt: 20 - Sayı: 4, 338–340. https://ajindex.com/articles/549440

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (6)

  1. Ryan TJ, Faxon DP, Gunnar RM, Kennedy JW, King SB 3rd, Loop FD, et al. Guidelines for percutaneous transluminal coronary angioplasty. report of American College of Cardiology/American Heart Association task force of assessment of diagnostic and therapeutic cardiovasculer procedures (Subcommitee of percutaneous transluminal coronary angioplasty). Circulation 1988;78:486—502
  2. Ellis SG, Ajluni S, Arnold AZ, Popma JJ, Bittl JA, Eigler NL, et al. Increased coronary perforation in the new device era. Incidence, classification, management, and outcome. Circulation 1994;906:2725—30
  3. Gruberg L, Pinnow E, Flood R, Bonnet Y, Tebeica M, Waksman R, et al. Incidence, management and outcome of coronary artery perforation during percutaneous coronary intervention. Am Cardiol 2000;86:680—2
  4. Shimony A, Joseph L, Mottillo S, Eisenberg MJ. Coronary artery perforation during percutaneous coronary intervention: systematic review and meta-analysis. Can Cardiol 2011;27:843—50
  5. Demir I. Perkütan girişimsel işlemlerin komplikasyonları. Turkiye Klinikleri Int Med Sci 2006;2215-26
  6. Briguori C, Nishida T, Anzuini A, Di Mario C, Grube E, stent implantation to treat coronary ruptures. Circulation Colombo A. Emergency polytetrafluoroethylene covered 2000;102:3028-31