Journals / İnönü Üniversitesi Tıp Fakültesi Dergisi / 2008 / Cilt: 15 - Sayı: 3

Evaluation of the vertebral artery using color duplex sonography in patients with vertebrobasilar insuffiency symptoms

Vertebrobaziller yetmezlik semptomları olan hastalarda vertebral arterin dupleks doppler us yöntemiyle değerlendirilmesi

Pages
163–168
Publication Date
2022-10-17
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Group 1 consist of patients with severely damped VA flow volume (

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Background: Hemodynamic changes of vertebral artery (VA) are aimed to be investigated in vertebrobasilar insuffiency patients.
📊
Key Findings & Data:Material And Methods: Velocity, volume, total volume, resistivity index (RI) and pulsatility index (PI) parameters of every two VA are utilized with Doppler US method in the VBI total 100 patients as 48 of male and 52 of female.
💡
Conclusion & Impact:Group 1 consist of patients with severely damped VA flow volume (
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Background: Hemodynamic changes of vertebral artery (VA) are aimed to be investigated in vertebrobasilar insuffiency patients. Material And Methods: Velocity, volume, total volume, resistivity index (RI) and pulsatility index (PI) parameters of every two VA are utilized with Doppler US method in the VBI total 100 patients as 48 of male and 52 of female. According to their volumes, the patients are divided to 3 groups. Group 1 consist of patients with severely damped VA flow volume (

Özet

Amaç: Vertebrobaziller yetmezliği olan hastalarda (VBY) vertebral arter (VA) hemodinamisindeki değişikliklerin araştırılmasıdır. Gereç ve Yöntem: VBY li 48’i erkek, 52’si kadın toplam 100 hastada Doppler US yöntemi ile her iki VA’in hız, volüm, toplam volüm, RI ve PI parametreleri değerlendirildi. Hastalar VA volumlerine göre 3 gruba ayrıldı. Grup 1 de VA volümünde şiddetli derecede azalma (200 ml/dk) normal olan hastalar yer aldı. Bulgular: Tüm olguların ortalama VA akım volümü 256 ± 51.80 mL/min (24–280 mL/min) olarak hesaplandı. VA pik sistolik akım hızında sağ tarafta ortalama 35.07±12.57 cm/s ve sol tarafta ortalama 42.99±12.99 cm/s idi. Akım volümü açısından taraflar karşılaştırıldığında sol taraf sağ taraftan belirgin olarak önemli derecede yüksekti (127.34 ± 54.69 mL/min vs. 83.46 ± 37.82 mL/min, P= 0.001). Sonuç: VBY tanısında doppler US kullanışlı bir tanı yöntemdir. VBY’ li hastalarda VA akım hızı ölçümlerine ek olarak volüm ölçümlerinin de yapılmasının tanıya katkısı mevcuttur.

🔖

Cite This Article

KAFADAR, H., BURAKGAZİ, G., ÇOLAK, C., KAFADAR, S., AYDIN, A. M. (2022). Evaluation of the vertebral artery using color duplex sonography in patients with vertebrobasilar insuffiency symptoms. İnönü Üniversitesi Tıp Fakültesi Dergisi, Cilt: 15 - Sayı: 3, 163–168. https://ajindex.com/articles/548612

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (3)

  1. Bradshaw P, McQuaid P. The syndrome of vertebrobasilar insufficiency. Q J Med 1963; 128: 279–96 2. Zwiebel WJ, Pellerito JS. Vasküler Ultrasona Giriş. Mihmanlı İ (Çeviren
  2. Baskı, İstanbul. İstanbul Medikal Yayıncılık 2006: 586–609 3. Yamasoba T, Kikuchi S, Higo R. Deafness associated with vertebrobasilar insufficiency. Journal of the Neurological Sciences 2001; 187: 69–75 4. Bulsara KR, Velez DA., Villavicencio A. Rotational vertebral artery insufficiency resulting from cervical spondylosis: case report and review of the literature. Surgical Neurology 2006; 65: 625– 7 5. Takayuki N, Hideo Y, Yoshiaki N, Toshinobu S, Tadayoshi T. Evaluation of the vertebrobasilar artery system by magnetic resonance angiography in the diagnosis of vertebrobasilar ınsufficiency. Acta Oto-Laryngologica. 1998; 118 (6): 54–7 6. Yazıcı B, Erdoğmuş B, Tugay A. Sağlıklı erişkinlerde serebral kan akımının karotid ve vertebral arter doppler ultrasonografi yoluyla ölçülmesi. Diagn interv radiol 2005; 11: 195–8 7. Baloh RW. Vertigo. Lancet 1998; 352: 1841–46 8. Rumack CM, Wilson SR, Charboneau JW. Diagnostic Ultrasound
  3. Baskı, St Louis: Mosby 1998; 1: 87–153 9. Trattnig S, Hubsch P, Schuster H. Color-coded Doppler imaging of normal vertebral arteries. Stroke 1999; 21: 1222–25 10. Bendick PJ, Jackson VP. Evaluation of the vertebral arteries with duplex sonography. J Vasc Surg 1986; 3: 523–30 11. Acar M, Yücel A, Değirmenci B, Albayrak R, Haktanır A. Tektaraflı vertebral arter hipoplazisine bağlı vertebrobaziler yetmezlik tanısında renkli Doppler sonografi. Tıp araştırmaları dergisi 2004; 2(1): 1–4 12. Bendick PJ, Glover JL. Vertebrobasilar insufficiency: evaluation by quantitative duplex flow measurements. A preliminary report. J Vasc Surg 1987; 5: 594–600 13. Yazıcı B, Erdoğmuş B, Tugay A. Sağlıklı erişkinlerde serebral kan akımının karotid ve vertebral arter doppler ultrasonografi yoluyla ölçülmesi. Diagn interv radiol 2005; 11: 195–8 14. Seidel E, Eicke BM, Tettenborn B, Krummenauer F. Reference values for vertebral artery flow volume by duplex sonography in young and elderly adults. Stroke 1999; 30: 2692–6 15. Özdemir ST, Yıldız C, Cankur ŞN. Sağlıklı popülasyonda vertebral arter sisteminin renkli Doppler ultrasonografi ile değerlendirilmesi. Uludağ Üniversitesi Tıp Fakültesi Dergisi 2002; 28 (3): 95–9 16. Acar M, Degirmenci B, Yucel A, Albayrak R, Haktanır A, Yaman M. Comparison of vertebral artery velocity and flow volume measurements for diagnosis of vertebrobasilar ins