⚡ TL;DR(Too Long; Didn't Read)

Without matrix effect, determination of pyrocatechol at lower peak potential (0.50 V) than oxidation peak potential (0.62 V) was carried out.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Determination of pyrocatechol was successfully achieved over polyaniline - poly(3-methylthiophene) - poly(3,3’-diaminobenzidine) (PANI - $P_3$MT - PDAB) coated Pt disc electrode using amperometric I-t method in $NaHSO_4/Na_2SO_4$ (SBS) (pH 2.0) solution.
📊
Key Findings & Data:The potential range of 0.45 V-0.65 V were implemented and a potential of 0.50 V was found to be an optimum potential.
💡
Conclusion & Impact:Without matrix effect, determination of pyrocatechol at lower peak potential (0.50 V) than oxidation peak potential (0.62 V) was carried out.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Determination of pyrocatechol was successfully achieved over polyaniline - poly(3-methylthiophene) - poly(3,3’-diaminobenzidine) (PANI - $P_3$MT - PDAB) coated Pt disc electrode using amperometric I-t method in $NaHSO_4/Na_2SO_4$ (SBS) (pH 2.0) solution. The potential range of 0.45 V-0.65 V were implemented and a potential of 0.50 V was found to be an optimum potential. Analytical parameters (LOD, LOQ and linear range) were 7.37×$10^{-5}$, 2.47×10-4 and 2.47×$10^{-4}$-25.0 mmol.$L^{-1}$, respectively. Furthermore, assay of pyrocatechol was performed in artificially contaminated river water samples over modified electrode at the pyrocatechol concentrations of 5.0 and 10.0 mmol.L-1 to check on the matrices interference and accuracy of the developed method. Recovery values were 101.1% and 101.2%, respectively. Without matrix effect, determination of pyrocatechol at lower peak potential (0.50 V) than oxidation peak potential (0.62 V) was carried out.

Özet

$NaHSO_4/Na_2SO_4$ (SBS) (pH 2.0) çözeltisi içerisinde amperometrik I-t yöntemi kullanılarak polianilin-poli(3- metiltiyofen)-poli(3,3’-diaminobenzidin) (PANI - 4P_3MT$ - PDAB) kaplı Pt disk elektrot üzerinden pirokatekol tayini başarılı bir şekilde gerçekleştirildi. 0,45 V–0,65 V aralığında potansiyel değerleri uygulandı ve 0.50 V optimum potansiyel olarak belirlendi. Analitik parametreler (gözlenebilme sınırı, alt tayin sınırı ve doğrusal çalışma aralığı) sırasıyla 7.37×10^{-5}$, 2.47×10^{-4}$ ve 2.47×10^{-4}$-25.0 mmol.$L^{-1}$ olarak bulundu. Ayrıca, matriks girişimini ve geliştirilen yöntemin doğruluğunu test etmek için, pirokatekol derişimi 5.0 ve 10.0 mmol.L-1 olacak şekilde yapay olarak kirletilmiş nehir sularında pirokatakol tayini gerçekleştirildi. Geri kazanım değerleri sırasıyla % 101.1 ve % 101.2, olarak elde edildi. Pirokatekolün yükseltgenme potansiyelinden (0.62 V) daha düşük potansiyelde (0.50 V) matriks etkisi olmaksızın pirokatakol tayini gerçekleştirildi.

🔖

Cite This Article

Kavanoz, M., Ülker, E. (2022). Electroanalysis of Pyrocatechol in River Water Over Pt Electrode Modified with Polyaniline-Poly(3-methylthiophene)- Poly(3,3’-diaminobenzidine) Film. Hacettepe Journal of Biology and Chemistry, Cilt: 44 - Sayı: 3, 339–347. https://ajindex.com/articles/529121

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. J. Wang, J.-N. Park, X.-Y. Wei, C.W. Lee, Roomtemperature heterogeneous hydroxylation of phenol with hydrogen peroxide over Fe2+, Co2+ ion-exchanged Naβ zeolite, Chem. Commun., 9 (2003) 628
  2. N. Alizadeh, H. Zarabadipour, A. Mohammadi, Headspace solid-phase microextraction using an electrochemically deposited dodecylsulfate-doped polypyrrole film to determine of phenolic compounds in water, Anal. Chim. Acta, 605 (2007) 159
  3. Q. Ameer, S.B. Adeloju, Development of a potentiometric catechol biosensor by entrapment of tyrosinase within polypyrrole film, Sens. Actuators B: Chem., 140 (2009) 5
  4. M. Castillo, R. Domingues, M.F. Alpendurada D. Barceló, Persistence of selected pesticides and their phenolic transformation products in natural waters using off-line liquid solid extraction followed by liquid chromatographic techniques, Anal. Chim. Acta, 353 (1997) 133
  5. R. Gatti, M.G. Gioia, A.M. Di Pietra V. Cavrini, Analysis of phenols in pharmaceuticals by liquid chromatography after pre-column labelling and online post-column photochemical derivatization, Anal. Chim. Acta, 447 (2001) 89
  6. C.D. Chriswell, R.C. Chang J.S. Fritz, Chromatographic determination of phenols in water, Anal. Chem., 47 (1975) 1325
  7. M. Naczk and F. Shahidi, Extraction analysis of phenolics in food, J. Chromatogr. A, 1054 (2004) 95
  8. G. Wang, X. He, F. Zhou, Z. Li, B. Fang, X. Zhang L. Wang, Application of gold nanoparticles/$TiO_2$ modified electrode for the electrooxidative determination of catechol in tea samples, Food Chem., 135 (2012) 446
  9. K. He, X. Wang, X. Meng, H. Zheng S.-i. Suye, Amperometric determination of hydroquinone and catechol on gold electrode modified by direct electrodeposition of poly(3,4-ethylene dioxythiophene), Sens. Actuators B: Chem., 193 (2014) 212
  10. M. Kavanoz N.Ö. Pekmez, Poly(vinylferrocenium) perchlorate–polyaniline composite film-coated electrode for amperometric determination of hydroquinone, J. Solid State Electrochem., 16 (2012) 1175
  11. Y. Tan, X. Guo, J. Zhang J. Kan, Amperometric catechol biosensor based on polyaniline–polyphenol oxidase, Biosens. Bioelectron., 25 (2010) 1681
  12. H. Zhang, A. Galal, J.F. Rubinson, I. Marawi, T.H. Ridgway, S.K. Lunsford, H. Zimmer H.B. Mark Jr, Flow injection amperometric detection of catechol using dual-band poly(3-methylthiophene) electrodes, Electrochim. Acta, 43 (1998) 3511
  13. M. Kavanoz, U. Bük E. Ülker, Determination of hydroquinone using poly(3-methylthiophene) synthesized electrochemica