Journals / Hacettepe Journal of Biology and Chemistry / 2019 / Cilt: 47 - Sayı: 3

A New, Sensitive and Disposable Electrochemical Immunosensor Based on Benzaldehyde Side Group Containing Phosphazene Polymer Modified ITO Substrate for Interleukin 1β Detection

Pages
305–315
Publication Date
2022-10-17
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The applicability of the suggested biosensor was tested by measuring IL 1β level in human serum and the suggested immunosensor had acceptable results for quantitative analysis.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, a novel electrochemical ultrasensitive immunosensor based on disposable benzaldehyde substituted phosp-hazene polymer (BSPP) modified ITO electrode was developed for interleukin 1β (IL 1β) detection.
📊
Key Findings & Data:These aldehyde groups pro-vided anchoring points for anti-IL 1β antibodies.
💡
Conclusion & Impact:The applicability of the suggested biosensor was tested by measuring IL 1β level in human serum and the suggested immunosensor had acceptable results for quantitative analysis.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

In this study, a novel electrochemical ultrasensitive immunosensor based on disposable benzaldehyde substituted phosp-hazene polymer (BSPP) modified ITO electrode was developed for interleukin 1β (IL 1β) detection. Aldehyde side groups containing phosphazene polymer (BSPP) synthesized via ring opening polymerization method. These aldehyde groups pro-vided anchoring points for anti-IL 1β antibodies. The production process of the proposed immunosensor was monitored by electrochemical techniques like Electrochemical Impedance Spectroscopy (EIS) and Cyclic Voltammetry (CV). In addition, these fabrication steps were characterized by utilizing Scanning Electron Microscopy (FE-SEM) and Atomic Force Micros-copy (AFM). Moreover, BSPP polymer layer on the polymer coated electrode surface was investigated by using Energy Dis-persive X-ray (EDX). The fabricated immunosensor had a low detection limit (9.3 fg/mL) and a wide linear detection range (0.03-7.5 pg/mL). Moreover, it had good reproducibility (1.82%), excellent repeatability (1.56%), good selectivity and high stability. The results of experiments showed that the BSPP polymer was desirable platform for IL 1β antigen detection in clinical diagnosis and practical applications. The applicability of the suggested biosensor was tested by measuring IL 1β level in human serum and the suggested immunosensor had acceptable results for quantitative analysis.

🔖

Cite This Article

AYDIN, M. (2022). A New, Sensitive and Disposable Electrochemical Immunosensor Based on Benzaldehyde Side Group Containing Phosphazene Polymer Modified ITO Substrate for Interleukin 1β Detection. Hacettepe Journal of Biology and Chemistry, Cilt: 47 - Sayı: 3, 305–315. https://ajindex.com/articles/529035

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. S. Kumar, R.K. Singh, R. Murthy, T. Bhardwaj, Synthesis and evaluation of substituted poly (organophosphazenes) as a novel nanocarrier system for combined antimalarial therapy of primaquine and dihydroartemisinin, Pharm. Res., 32 (8) (2015) 2736-2752
  2. H.R. Allcock, The synthesis of functional polyphosphazenes and their surfaces, Appl. Organomet. Chem., 12 (10-11) (1998) 659-666
  3. J. Dudás, A. Fullár, M. Bitsche, V. Schartinger, I. Kovalszky. G.M. Sprinzl, H.J.E.c.r. Riechelmann, Tumor-produced. active Interleukin-1 β regulates gene expression in carcinoma-associated fibroblasts, Exp. Cell. Res., 317 (2011) 2222-2229
  4. E.B. Aydın, M. Aydın, M.K. Sezgintürk, Highly sensitive electrochemical immunosensor based on polythiophene polymer with densely populated carboxyl groups as immobilization matrix for detection of interleukin 1β in human serum and saliva, Sens. Actuator. B, 270 (2018) 18-27
  5. E.B. Aydın, M.K. Sezgintürk, A disposable and ultrasensitive ITO based biosensor modified by 6-phosphonohexanoic acid for electrochemical sensing of IL-1β in human serum and saliva, Anal. Chim. Acta, 1039 (2018) 41-50
  6. C.E. Krause, B.A. Otieno, G.W. Bishop, G. Phadke, L. Choquette, R.V. Lalla, D.E. Peterson, J.F. Rusling, Ultrasensitive microfluidic array for serum pro-inflammatory cytokines and C-reactive protein to assess oral mucositis risk in cancer patients, Anal. Bioanal. Chem., 407 (2015) 7239-7243
  7. C.-Y. Chiang, M.L. Hsieh, K.W. Huang, L.K. Chau, C.M. Chang, S.-R. Lyu, Fiber-optic particle plasmon resonance sensor for detection of interleukin-1β in synovial fluids, Biosens. Bioelectron., 26 (2010) 1036-1042
  8. A. Baraket, M. Lee, N. Zine, M. Sigaud, J. Bausells, A. Errachid, A fully integrated electrochemical biosensor platform fabrication process for cytokines detection, Biosens. Bioelectron., 93 (2017) 170-175
  9. J. Amani, M. Maleki, A. Khoshroo, A. Sobhani-Nasab, M. Rahimi-Nasrabadi, An electrochemical immunosensor based on poly p-phenylenediamine and graphene nanocomposite for detection of neuron-specific enolase via electrochemically amplified detection, Anal. Biochem., 548 (2018) 53-59
  10. M. Aydın, E.B. Aydın, M.K. Sezgintürk, A disposable immunosensor using ITO based electrode modified by a star-shaped polymer for analysis of tumor suppressor protein p53 in human serum, Biosens. Bioelectron., 107 (2018) 1-9
  11. P. Khashayar, G. Amoabediny, B. Larijani, M. Hosseini, J. Vanfleteren, Fabrication and Verification of Conjugated AuNP-Antib