Journals / Hacettepe Journal of Biology and Chemistry / 2008 / Cilt: 36 - Sayı: 1

Plasma modified foley catheters against to catheter associated urinary tract infection (CAUTI)

Pages
1–8
Publication Date
2022-10-17
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The obtained results showed that the plasma power affected hidrophilicity of the surface and wettability of the foley catheters was increased.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study; the foley catheters were modified by plasma polymerization technique and coated with alginate gels.
📊
Key Findings & Data:The obtained results showed that the plasma power affected hidrophilicity of the surface and wettability of the foley catheters was increased.
💡
Conclusion & Impact:As the numerical values of the obtained data; while the amount of bacterial colony formation unit was at 108 level initially, it was decreased down to 104-103 level by changing the surface hydrophilicities as expected.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

In this study; the foley catheters were modified by plasma polymerization technique and coated with alginate gels. This modification processes were applied to prevent bacterial adhesion onto the foley catheter surfaces. Here the most effective parameters were evaluated as the plasma polymerization system power and plasma exposure time for the effective catheter surface modification. The obtained results showed that the plasma power affected hidrophilicity of the surface and wettability of the foley catheters was increased. The plasma exposure time increased the amount of EDA deposition over the catheter surfaces and then caused more hydrophilicity for the foley catheter surfaces also. In this study, the bacterial strain of E. Coli had a hydrophobic nature and therefore the increase in hydrophilicity of the surface of foley catheters decreased the adhesion risk for the E. Coli onto the catheter surfaces. As the numerical values of the obtained data; while the amount of bacterial colony formation unit was at 108 level initially, it was decreased down to 104-103 level by changing the surface hydrophilicities as expected.

🔖

Cite This Article

EROĞLU, M., ÖZTÜRK, E., ATİLLA, P., ERDOĞAN, G., DENKTAŞ, E. B., AĞALAR, C. (2022). Plasma modified foley catheters against to catheter associated urinary tract infection (CAUTI). Hacettepe Journal of Biology and Chemistry, Cilt: 36 - Sayı: 1, 1–8. https://ajindex.com/articles/527847

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (15)

  1. Riedl C.R., Witkowski M., Plas E., Pflueger H., Heparin coating reduces encrustation of ureteral stents: a preliminary report, International Journal of Antimicrobial Agents, 19 (2002) 507
  2. Schierholz J.M., Yücel N., Rump A.F.E., Beuth J, Pulverer G., Antiinfective and encrustation-inhibiting materials/myth and facts, International Journal of Antimicrobial Agents, 19 (2002) 511
  3. Reid G., Davidson R., Denstedt D. XPS, SEM and EDX analysis of conditioning lm deposition onto ureteral stents, Surf Interface Anal, 21 (1994) 58
  4. Keane P.F., Bonner M.C., Johnston S.R., Zafar A., Gorman S.P. Characterization of bio"lm and encrustation on ureteric stents in vivo, Br J Urol, 73 (1994) 687
  5. Santin M., Motta A., Denyer S.P., Cannas M., Effect of the urine conditioning film on ureteral stent encrustation and characterization of its protein composition, Biomaterials, 20 (1999) 1245
  6. Elves AWS, Feneley RCL. Long-term urethral catheterization and the urine biomaterial interface, Br J Urol, 80 (1997) 1
  7. Schierholz JM, Beuth J. Sophisticated medical devices as local drug delivery systems, Med Dev Tech, 11(2) (2000) 12
  8. Schierholz JM, Beuth J. Implant infections haven for opportunistic bacteria, J Hosp Inf, 49 ( 2001) 87
  9. DiTizio V., Ferguson G.W., Mittelman M.W., Khoury A.E., Bruce A.W., DiCosmo F., A liposomal hydrogel for the prevention of bacterial adhesion to catheters, Biomaterials, 19 (1998) 1877
  10. Park J.H., Cho Y.W., Kwon I.C., Jeong S.Y., Bae Y.H., Assessment of PEO/PTMO multi block copolymer segmented polyurethane blends as coating materials for urinary catheters: in vitro bacterial adhesion and encrustation behavior, Biomaterials, 23 (2002) 399
  11. Kim C.K. and Lee E. J. Int. J. Pharm, 79 (1992) 11
  12. Downs E.C., Robertson N.E., Riss, T.L. and Plunkett M.L., J. Cell Phys., 152 (1992) 422
  13. Edelman E.R., Mathiowitz E., Langer R. and Klagsbrun M. Biomaterials, 12 (1991) 619
  14. Mumper R.J., Hoffman A.S., Puolakkainen P.A., Bouchard L.S. and Gombotz W.R., J. Control. Release, 30 (1994) 241
  15. Sandford P.A. and Hutchings G.P. In: Yalpani, M. (ed.), Industrial Polysaccharides, Genetic Engineering, Structure/Property Relations and Applications, (1987) 363.