Journals / Glokom Katarakt / 2021 / Cilt: 16 - Sayı: 3

Objective Evaluation of Corneal Clarity in Pigment Dispersion Syndrome and Pigmentary Glaucoma

Pages
138–143
Publication Date
2022-10-18
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion: The presence of Krukenberg spindle, higher age in PG and the probable effects of glaucoma might cause corneal backscatter of light and increased CD particularly in anterior layers in central zones of cornea.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Purpose: To compare the corneal densitometry (CD) measurements in patients with pigment dispersion syndrome (PDS) and pigmentary glaucoma (PG).
📊
Key Findings & Data:Materials and Methods: This prospective comparative study included 22 eyes with PG, 19 eyes with PDS and 21 control individuals.
💡
Conclusion & Impact:Conclusion: The presence of Krukenberg spindle, higher age in PG and the probable effects of glaucoma might cause corneal backscatter of light and increased CD particularly in anterior layers in central zones of cornea.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Purpose: To compare the corneal densitometry (CD) measurements in patients with pigment dispersion syndrome (PDS) and pigmentary glaucoma (PG). Materials and Methods: This prospective comparative study included 22 eyes with PG, 19 eyes with PDS and 21 control individuals. After complete ophthalmological examination, all the eyes had central corneal thickness (CCT) and CD measurements by densitometry software of Pentacam HR-Scheimpflug corneal topography over a 12-mm diameter of the cornea. Chi-Square, Kolmogorov-Smirnov, analysis of variance, and Tukey’s post-hoc tests were used for statistical analysis. Results: All the eyes with PG were under prostaglandin monotherapy. The mean CCT was significantly higher in PG cases than the other groups (p=0.01). The mean CD of anterior layer at the 0-2 mm was significantly higher in PG than PDS cases and normal subjects (p=0.007). The mean CD of total layer at the 0-2 mm was significantly higher in PG cases than control subjects (p=0.03). The mean CD of anterior layer at the 2-6 mm was significantly higher in PG than PDS cases (p=0.04). There were no significant differences of CD in other zones and layers between the groups. Conclusion: The presence of Krukenberg spindle, higher age in PG and the probable effects of glaucoma might cause corneal backscatter of light and increased CD particularly in anterior layers in central zones of cornea.

🔖

Cite This Article

ŞİMŞEK, M., ELGİN, U., ŞEN, E., YEŞİLYAPRAK, N., YILDIRIM, D. (2022). Objective Evaluation of Corneal Clarity in Pigment Dispersion Syndrome and Pigmentary Glaucoma. Glokom Katarakt, Cilt: 16 - Sayı: 3, 138–143. https://ajindex.com/articles/525754

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (15)

  1. Okafor K, Vinod K, Gedde SJ. Update on pigment dispersion syndrome and pigmentary glaucoma. Curr Opin Ophthalmol 2017;28:154-60
  2. Scuderi G, Contestabile MT, Scuderi L, et al. Pigment dispersion syndrome and pigmentary glaucoma: a review and update. Int Ophthalmol 2019;39:1651-62
  3. Tandon A, Zhang Z, Fingert JH, et al. The heritability of pigment dispersion syndrome and pigmentary glaucoma. Am J Ophthalmol 2019;202:55-61
  4. Cankaya AB, Tekin K, Kiziltoprak H, et al. Assessment of corneal backward light scattering in the healthy cornea and factors affecting corneal transparency. Jpn J Ophthalmol 2018;62:335- 41
  5. Garzón N, Poyales F, Illarramendi I, et al. Corneal densitometry and its correlation with age, pachymetry, corneal curvature, and refraction. Int Ophthalmol 2017;37:1263-8
  6. Pekel G, Özbakış F, Bahar A, et al. Correlations of corneal optical densitometry, endothelial hexagonality percentage and epithelium thickness. Curr Eye Res 2018;43:170-4
  7. Tekin K, Sekeroglu MA, Kiziltoprak H, et al. Corneal densitometry in healthy corneas and its correlation with endothelial morphometry. Cornea 2017;36:1336-42
  8. Simsek M, Cakar Ozdal P, Cankurtaran M, et al. Analysis of corneal densitometry and endothelial cell function in Fuchs uveitis syndrome. Eye Contact Lens 2021;47:196-202
  9. Lord FD, Pathanapitoon K, Mikelberg FS. Keratometry and axial length in pigment dispersion syndrome: a descriptive case- control study. J Glaucoma 2001;10:383-5
  10. Yip LW, Sothornwit N, Berkowitz J, et al. A comparison of interocular differences in patients with pigment dispersion syndrome. J Glaucoma 2009;18:1-5
  11. Murrell WJ, Shihab Z, Lamberts DW, et al. The corneal endothelium and central corneal thickness in pigmentary dispersion syndrome. Arch Ophthalmol 1986;104:845-6
  12. Cankaya AB, Tekin K, Inanc M. Effect of pseudoexfoliation on corneal transparency. Cornea 2016;35:1084-8
  13. Sekeroglu MA, Anayol MA, Gulec M, et al. Corneal densitometry: a new technique for objective assessment of corneal corneal clarity in pseudoexfoliation syndrome. J Glaucoma 2016;25:775-9
  14. Di Staso S, Agnifili L, Cecannecchia S, et al. In vivo analysis of prostaglandins-induced ocular surface and periocular adnexa modifications in patients with glaucoma. In Vivo 2018;32:211- 20
  15. Meda R, Wang Q, Paoloni D, et al. The impact of chronic use of prostaglandin analogues on the biomechanical properties of the cornea in patients with primary open-angle glaucoma. Br J Ophthalmol