Journals / Geosound / 1997 / Cilt: 1 - Sayı: 30

Model tank work with mechanic relay separator

Mekanik röle separatörlü iletken tank modeli çalışması

Journal
Geosound
Pages
319–329
Publication Date
2022-10-18
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Moreover, an approximate measurement ratio was determined depending on the dimentions of the model tank considering the effects of the model tank walls and the disturbances at the discontinuities.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study,the resistivity and induced polarization (IP) effect of a conducting model in anticlinal shape were determined by using Schlumberger, Wenner and dipol- dipol elektrode configurations.The response of the conducting model was compared individualy by applying the current with unipole and bipole polarities in the resistivity measurements.
📊
Key Findings & Data:In this model work, a mechanic relay which switches the unipole and bipole measuring units was developed.
💡
Conclusion & Impact:Moreover, an approximate measurement ratio was determined depending on the dimentions of the model tank considering the effects of the model tank walls and the disturbances at the discontinuities.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

In this study,the resistivity and induced polarization (IP) effect of a conducting model in anticlinal shape were determined by using Schlumberger, Wenner and dipol- dipol elektrode configurations.The response of the conducting model was compared individualy by applying the current with unipole and bipole polarities in the resistivity measurements. In this model work, a mechanic relay which switches the unipole and bipole measuring units was developed. The IP model was applied to the conducting model and the relations among the metal factor and resistivity parameters versus depths including critical anomalies were determined. A good consistency were observed between the resistivity profiles of Schlumberger and dipol-dipol systems at certain depths. Moreover, an approximate measurement ratio was determined depending on the dimentions of the model tank considering the effects of the model tank walls and the disturbances at the discontinuities.

Özet

Bu çalışmada; Schlumberger, Wenner ve dipol- dipole dizilimleri ile doğru akım özdirenç ve l.P (Induced Polarized) yöntemleri kullanılarak, antiklinal şeklindeki iletken bir modelin yanal ve düşey uzaklıktaki özdirenç etkileri belirlenmiştir. Özdirenç ölçümlerinde, ortama Unipol (eş kutuplu) ve Bipol (zıt kutuplu) akım uygulanarak, iletken modelin tepkisi ayrı ayrı kıyaslanmıştır. Yapılan bu model çalışmalarında, her iki ölçüm sistemi için mekanik röleli bir ayırıcı düzenek (separator) geliştirilmiştir. İletken antiklinal modele, dipole - dipole açılımlı IP yöntemi de uygulanarak, değişen derinliklerdeki metal faktör (MF) ile özdirenç (p) parametreleri arasındaki ilişkiler ve kritik anomali belirlenmiştir. Deneysel çalışmaların sonucunda, Schlumberger ile Dipole-Dipole ölçüm sistemleri ile ilgili özdirenç profilleri arasında belirli derinliklerde iyi bir uyum görülmüştür. Ayrıca , bir anomali kaynağı olarak alınan antiklinal modelin ortam-süreksizlik geçişindeki bozulmaları ve model tankının duvar etkileri de incelenerek, model tankı boyutlarına göre yaklaşık bir ölçüm oranı belirlenmiştir.

🔖

Cite This Article

YEKEN, T., KURTULUŞ, C. (2022). Model tank work with mechanic relay separator. Geosound, Cilt: 1 - Sayı: 30, 319–329. https://ajindex.com/articles/525119