Journals / Gazi University Journal of Science / 2018 / Cilt: 31 - Sayı: 1

Electrochemical Behaviour of Ofloxacin in Pharmaceutical and Biological Samples Using a Boron-Doped Diamond Electrode in Using Anionic Surfactant

Pages
66–80
Publication Date
2022-10-19
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In this way, BDD electrode may represent an efficient alternative towidely used modified electrodes in the determination of fluoroquinolone compounds.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:This paper examined use of a boron doped diamond electrode (BDDE) for the electroanalysis ofofloxacin (one of the fluoroquinolone compounds) by cyclic voltammetry (CV) and squarewave voltammetry (SWV) in the presence of anionic surfactant (sodium dodecyl sulfate, SDS).The current signal due to the oxidation process was a function of the amount of ofloxacin, pH ofthe medium, effect of SDS and scan rate.
📊
Key Findings & Data:Cyclic voltammetric studies indicated an irreversiblebehaviour of ofloxacin in phosphate buffer solution at pH 2.0 with well-defined oxidation peakat +1.24 V (absence SDS) and +1.21 V (presence of SDS) vs.
💡
Conclusion & Impact:In this way, BDD electrode may represent an efficient alternative towidely used modified electrodes in the determination of fluoroquinolone compounds.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

This paper examined use of a boron doped diamond electrode (BDDE) for the electroanalysis ofofloxacin (one of the fluoroquinolone compounds) by cyclic voltammetry (CV) and squarewave voltammetry (SWV) in the presence of anionic surfactant (sodium dodecyl sulfate, SDS).The current signal due to the oxidation process was a function of the amount of ofloxacin, pH ofthe medium, effect of SDS and scan rate. Cyclic voltammetric studies indicated an irreversiblebehaviour of ofloxacin in phosphate buffer solution at pH 2.0 with well-defined oxidation peakat +1.24 V (absence SDS) and +1.21 V (presence of SDS) vs. Ag/AgCl, respectively. Withoptimized experimental parameters, the current response of ofloxacin was proportionally linearin the concentration range from 1.0×10-7 to 3.5×10-6 M. A detection limit of 1.76×10-8 M wasobserved anodically electrochemical surface pretreatments. The practical applicability of thedeveloped method was demonstrated on the determination of ofloxacin in human urine andpharmaceutical samples. In this way, BDD electrode may represent an efficient alternative towidely used modified electrodes in the determination of fluoroquinolone compounds.

🔖

Cite This Article

PINAR, P. T. (2022). Electrochemical Behaviour of Ofloxacin in Pharmaceutical and Biological Samples Using a Boron-Doped Diamond Electrode in Using Anionic Surfactant. Gazi University Journal of Science, Cilt: 31 - Sayı: 1, 66–80. https://ajindex.com/articles/521406

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (9)

  1. Li, R., Lv, S., Shan, J., Zhang, J., “A novel electrochemical method for ofloxacin determination based on interaction of ofloxacin with cupric ion”, Ionics, 21(11): 3117–3124, (2015).
  2. Golcu, A., “Ofloxacin metal complexes: synthesis, characterization, analytical properties, and DNA binding studies”,Synthesis and Reactivity in Inorganic, Metal-Organic, and Nano-Metal Chemistry, 44(10): 1509-1520, (2014).
  3. Ballesteros, O., Vı́ lchez, J. L., Navalón, A. “Determination of the antibacterial ofloxacin in human urine and serum samples by solid-phase spectrofluorimetry”, Journal of Pharmaceutical and Biomedical Analysis, 30(4): 1103–1110, (2002).
  4. Okazaki, O., Aoki, H., Hakusui, H., “High-performance liquid chromatographic determination of (S)- (−)-ofloxacin and its metabolites in serum and urine using a solid-phase clean-up”,Journal of Chromatography B: Biomedical Sciences and Applications, 563(2): 313-322, (1991).
  5. Vosough, M., Rashvand, M., Esfahani, H.M., Kargosha, K., Salemi, A., “Direct analysis of six antibiotics in wastewater samples using rapid high-performance liquid chromatography coupled with diode array detector: A chemometric study towards green analytical chemistry”, Talanta, 135(1): 7– 17, (2015). Cañada-Cañada, F., Espinosa-Mansilla, A., Muñoz de la Peña, A., “Separation of fifteen quinolones by high performance liquid chromatography: Application to pharmaceuticals and ofloxacin determination in urine”, Journal of Separation Science, 30(9): 1242 – 1249, (2007).
  6. Espinosa-Mansilla, A., Muñoz de la Peña, A., González Gómez, D., Salinas, F., “HPLC determination of enoxacin, ciprofloxacin, norfloxacin and ofloxacin with photoinduced fluorimetric (PIF) detection and multiemission scanning: Application to urine and serum”, Journal of Chromatography B, 822(1- 2): 185-193, (2005).
  7. Immanuel, C., Hemanth Kumar, A. K., “Simple and rapid high-performance liquid chromatography method for the determination of ofloxacin concentrations in plasma and urine”, Journal of Chromatography B: Biomedical Sciences and Applications, 760(1): 91-95, (2001).
  8. Puranik, M., Bhawsar, D. V., Rathi, P., Yeole, P.G., “Simultaneous determination of ofloxacin and ornidazole in solid dosage form by RP-HPLC and HPTLC techniques”, The Indian Journal of Pharmaceutical Sciences, 72(4): 513-517, (2010).
  9. Kraemer, H., Gehrke, R., Breithaupt, A., Breithaupt, H., “Simultaneous quantification of cefotaxime, desacetylcefotaxime, ofloxacine and ciprofloxacine in ocular aqueous humor and in plasma by h