Journals / Florence Nightingale journal of nursing (Online) / 2020 / Cilt: 28 - Sayı: 2

The Effect of Cuff Size on Blood Pressure Measurement in Obese Surgical Patients: A Prospective Crossover Clinical Trial

Pages
205–212
Publication Date
2022-10-12
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Systolic blood pressure of the patients with a small adult cuff was 20.78 mmHg higher than that obtained with a cuff properly sized for mid-upper arm circumference, and their diastolic blood pressure was 10.15 mmHg higher on average (p

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Aim: This study aimed to determine the effect of a cuff properly sized for mid-upper arm circumference on blood pressure measurement in obese surgical patients.Method: This prospective crossover clinical trial was conducted with 100 patients who had body mass index ≥30 kg/m2 and mid-upper arm circumference ≥27 cm and were admitted to the general surgery unit of a medical faculty hospital in İstanbul, Turkey between January 1, 2015, and December 31, 2015.
📊
Key Findings & Data:Blood pressure of the patients was measured using a small-sized adult cuff and a cuff properly sized for mid-upper arm circumference.Results: Among the patients, 39% were morbidly obese and 67% had mid-upper arm circumference between 35 and 44 cm.
💡
Conclusion & Impact:Systolic blood pressure of the patients with a small adult cuff was 20.78 mmHg higher than that obtained with a cuff properly sized for mid-upper arm circumference, and their diastolic blood pressure was 10.15 mmHg higher on average (p
🔬Design:Research Article
📍Scope:2015 Verileri
⚙️Variables:Domain Parameters

Abstract

Aim: This study aimed to determine the effect of a cuff properly sized for mid-upper arm circumference on blood pressure measurement in obese surgical patients.Method: This prospective crossover clinical trial was conducted with 100 patients who had body mass index ≥30 kg/m2 and mid-upper arm circumference ≥27 cm and were admitted to the general surgery unit of a medical faculty hospital in İstanbul, Turkey between January 1, 2015, and December 31, 2015. Blood pressure of the patients was measured using a small-sized adult cuff and a cuff properly sized for mid-upper arm circumference.Results: Among the patients, 39% were morbidly obese and 67% had mid-upper arm circumference between 35 and 44 cm. Systolic blood pressure of the patients with a small adult cuff was 20.78 mmHg higher than that obtained with a cuff properly sized for mid-upper arm circumference, and their diastolic blood pressure was 10.15 mmHg higher on average (p

🔖

Cite This Article

UĞRAŞ, G. A., YÜKSEL, S., ALTINOK, N., DEMİR, N. (2022). The Effect of Cuff Size on Blood Pressure Measurement in Obese Surgical Patients: A Prospective Crossover Clinical Trial. Florence Nightingale journal of nursing (Online), Cilt: 28 - Sayı: 2, 205–212. https://ajindex.com/articles/517388

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (5)

  1. Akpolat, T., Kaya, C., Utaş, C., Arinsoy, T., Taşkapan, H., Erdem, E., et al. (2013). Arm circumference: Its importance for dialysis patients in the obesity era. International Urology and Nephrology, 45(4), 1103-1110. [Crossref] Alpar, R. (2018). Sınıf içi güvenirlik katsayısı. In Spor, sağlık ve eğitim bilimlerinden örneklerle uygulamalı istatistik ve geçerlik güvenirlik. (5.ed., pp.560). Ankara:
  2. Detay Yayıncılık. Arıcı, M., Birdane, A., Güler, K., Yıldız, B. O., Altun, B., Ertürk, Ş., et al. (2015). Turkish hypertension consensus report. Archives of the Turkish Society of Cardiology, 43(4), 402–409. [Crossref] Aşık, M., Aydoğdu, A., Bayram, F., Bilen, H., Can, S., Cesur, M., et al. (2018). Hipertansiyon tanı ve tedavi kılavuzu. (pp. 1-5). Ankara:
  3. Miki Matbaacılık. Bilo, G., Sala, O., Perego, C., Faini, A., Gao, L., Głuszewska, A., et al. (2017). Impact of cuff positioning on blood pressure measurement accuracy: May a specially designed cuff make a difference? Hypertension Research, 40(6), 573-580. [Crossref] Bonso, E., Saladini, F., Zanier, A., Benetti, E., Dorigatti, F., & Palatini, P. (2010). Accuracy of a single rigid conical cuff with standard-size bladder coupled to an automatic oscillometric device over a wide range of arm circumferences. Hypertension Research, 33(11), 1186-1191. [Crossref] http://dx.doi.org/10.1038/hr.2010.146
  4. Eley, V. A., Christensen, R., Guy, L., & Dodd, B. (2019). Perioperative blood pressure monitoring in patients with obesity. Anesthesia & Analgesia, 128(3), 484-491. [Crossref] Fonseca-Reyes, S., de Alba-Garcia, J. G., Parra-Carrillo, J. Z., & Paczka-Zapata, J.A. (2003). Effect of standard cuff on blood pressure readings in patients with obese arms. How frequent are arms of a ‘large circumference’? Blood Press Monitoring, 8(3), 101-106. Retrieved from: https://www.ncbi.nlm.nih.gov/pubmed/12900586.
  5. Irving, G., Holden, J., Stevens, R., & McManus, R.J. (2016). Which cuff should I use? Indirect blood pressure measurement for the diagnosis of hypertension in patients with obesity: A diagnostic accuracy review. BMJ Open, 6(11), e012429. [Crossref] Loenneke, J. P., Loprinzi, P. D., Abe, T., Thiebaud, R. S., Allen, K. M., Grant-Mouser, J., et al. (2016). Arm circumference influences blood pressure even when applying the correct cuff size: Is a further correction needed? International Journal of Cardiology, 202, 743-744. [Crossref] McFarlane, J. (2012). Blood pressure measurement in obese patients. Critical Care Nurse, 32(6), 70-73. [