Journals / European Mechanical Science / 2018 / Cilt: 2 - Sayı: 2

A Short Survey on Currently Used Experimental Setupsfor Testing Glaucoma Drainage Devices

Pages
60–67
Publication Date
2022-10-12
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In this study,one branch of them, in-vitroexperimental setups currently usedin testing of glaucoma drainage devices are surveyed.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Commonly used glaucoma drainage devices have many disadvantageouscircumstancesespecially inpostoperative period such as hypotony, flammation, etc.
📊
Key Findings & Data:There are great efforts to overcome these problemsin literature.
💡
Conclusion & Impact:In this study,one branch of them, in-vitroexperimental setups currently usedin testing of glaucoma drainage devices are surveyed.
🔬Design:Survey & Empirical Study
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Commonly used glaucoma drainage devices have many disadvantageouscircumstancesespecially inpostoperative period such as hypotony, flammation, etc. There are great efforts to overcome these problemsin literature. Researchershave investigated glaucoma drainage devicesby in-vivo, ex-vivo and in-vitroexperimental setups and tried to overcome their disadvantages. In this study,one branch of them, in-vitroexperimental setups currently usedin testing of glaucoma drainage devices are surveyed.

🔖

Cite This Article

GÜNGÖR, K., KARA, E., TURHAN, S., KUTLAR, A. İ. (2022). A Short Survey on Currently Used Experimental Setupsfor Testing Glaucoma Drainage Devices. European Mechanical Science, Cilt: 2 - Sayı: 2, 60–67. https://ajindex.com/articles/512480

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. Jyoti G.K. (2006). Numerical Solution of Flow Resistance In Outflow Pathway And Intravitreal Drug Delivery In Vitrectomised Eyes Mechanical Engineering. M.S. Thesis, Louisiana State University
  2. Moon S., Im S., An J., Ju Park C., Kim H. G., Park S. W., Kim H. I., Lee J.H. (2011). Selectively bonded polymeric glaucoma drainage device for reliable regulation of intraocular pressure. Biomed Microdevices, 14:325-335
  3. Schwartz K. S., Lee R. K., Gedde S.J., (2006). “Glaucoma drainage implants: critical comparison of types”, Current Opinion in Ophthalmology, 101(5), 872-5
  4. Kara, E. (2008). “Design of an alternative glaucoma drainage device using CFD tools”. M.S. Thesis, Universty of Gaziantep
  5. DeCroos F.C., Kondo Y., Mordes D., Lee M.R., Ahmad S., Asrani S., Allingham R.R., Olbrich K.C., Klitzman B. (2011) “In vitro fluid Dynamics of the ahmed glaucoma valve modified with expandedpolytetrafluoroethylene”, Current Eye Research, 36:2,112-117
  6. Maleki T., Member,IEEE, Chitnis G., Park J.H., Cantor L.B, Ziaie B.,Senior Member, IEEE. (2012). “Biodegradable microfabricated plug-filters for glaucoma drainage devices”,IEEE Trans Biomed Eng. 2012 Jun;59(6):1507-13
  7. Siewert S., Schultze C., Schmidt W., Hinze U., Chichkov B., Wree A., Sternberg K., Allemann R., Guthoff R., Schmitz KP. (2012) “Development of a micro-mechanical valve in a novel glaucoma implant”, Biomed Microdevices. 2012 Oct;14(5):907-20
  8. Schmidt W., Quosdorf D., Siewert S., Hinze U., Chichkov B., Brede M., Leder A., Guthoff R., Schmitz K.-P. (2012). “Micro particle-image-velocimetry for characterization of a micro-mechanical valve in a glaucoma implant”, Biomed Tech 2012; 57 (Suppl. 1)
  9. Siewert s., Schultze C., Schmidt W., Hinze U., Schmitz K.-P. (2010). “Adaptierte biegesteifigkeit und micromechanische ventile in einem neuartigen glaukomimplantat – finite-elemente-analyse und experimentelle untersuchungen, Biomed Tech 2010; 55 (Suppl
  10. DOI 10.1515/BMT.2010.363 [10] Paschalis El., Chodosh J., Sperling RA., Salvador-Culia B., Dohlman C., (2013). “A novel implantable glaucoma valve using ferrofluid”, PLoS ONE 8(6): e67404
  11. Luong Q.M., Shang L., Kong J.F., Peng Y., Wong T.T., Venkatraman S.S. (2013) “A new design and application of bioelastomers for beter control of intraocular pressure in a glaucoma drainage device”, Adv Healthc Mater. 2014 Feb;3(2):205-13. doi: 10.1002/adhm.201300113. Epub 2013 Jul 9
  12. Villamarin A., Roy S., Bigler S., Stergiopulos N., (2014). “ A