Journals / European Journal of Technique / 2020 / Cilt: 10 - Sayı: 2

NUMERICAL INVESTIGATION OF THE EFFECTS OF CONE TIP DIAMETERS ON THE EFFICIENCY OF A CYCLONE SEPARATOR

Pages
295–401
Publication Date
2022-10-12
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

As a result of the study, it has been observed that the effect of the cone tip diameter has a non-ignorable importance at varying fluid inlet velocities and particle sizes.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Cyclone separators, which are widely used in the cement industry, are very important in terms of preventing air pollution.
📊
Key Findings & Data:Geometries with four different cone tip diameters (60, 90, 120 and 150 mm) designed for this purpose were examined in three different flow rates and three different particle sizes (2, 4 and 6 µm).
💡
Conclusion & Impact:As a result of the study, it has been observed that the effect of the cone tip diameter has a non-ignorable importance at varying fluid inlet velocities and particle sizes.
🔬Design:Modeling & Simulation
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Cyclone separators, which are widely used in the cement industry, are very important in terms of preventing air pollution. Many studies on cyclone separators have been done for a long time by means of different models and with considering various parameters. Although much work has been done on the separators, there is no general agreement about the effect of the cone tip diameter on cyclone collection efficiency and / or a pressure drop. In this study, the effect of the cone tip diameter on the cyclone efficiency and the pressure drop was investigated in order to contribute to the literature in this regard. Geometries with four different cone tip diameters (60, 90, 120 and 150 mm) designed for this purpose were examined in three different flow rates and three different particle sizes (2, 4 and 6 µm). In Computational Fluid Dynamics (CFD) analysis, the turbulence was modeled using the Reynolds Stress Model (RSM). As a result of the study, it has been observed that the effect of the cone tip diameter has a non-ignorable importance at varying fluid inlet velocities and particle sizes.

🔖

Cite This Article

ÖZKAN, M., KAYA, A. M. (2022). NUMERICAL INVESTIGATION OF THE EFFECTS OF CONE TIP DIAMETERS ON THE EFFICIENCY OF A CYCLONE SEPARATOR. European Journal of Technique, Cilt: 10 - Sayı: 2, 295–401. https://ajindex.com/articles/512012

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. A. Kçpa. (2010). Division of outlet flow in a cyclone vortex finder - The CFD calculations, Sep. Purif. Technol., vol. 75, no. 2, pp. 127–131, 2010, doi: 10.1016/j.seppur.2010.08.009
  2. P. Silva, C. Briens, and A. Bernis. (2003). Development of a new rapid method to measure erosion rates in laboratory and pilot plant cyclones, Powder Technol. - POWDER TECHNOL, vol. 131, pp. 111–119, Apr. 2003, doi: 10.1016/S0032-5910(02)00338-8
  3. B. Zhao, H. Shen, and Y. Kang. (2004). Development of a symmetrical spiral inlet to improve cyclone separator performance, Powder Technol., vol. 145, no. 1, pp. 47–50, 2004, doi: 10.1016/j.powtec.2004.06.001
  4. A. Avci and I. Karagoz. (2003). Effects of flow and geometrical parameters on the collection efficiency in cyclone separators, J. Aerosol Sci., vol. 34, pp. 937–955, Jul. 2003, doi: 10.1016/S0021-8502(03)00054-5
  5. J. Chen, X. Lu, H. Liu, and C. Yang. (2006). Effect of the bottom-contracted and edge-sloped vent-pipe on the cyclone separator performance, Chem. Eng. J. - CHEM ENG J, vol. 129, pp. 85–90, May 2007, doi: 10.1016/j.cej.2006.11.005
  6. F. Qian and M. Zhang. (2005). Study of the natural vortex length of a cyclone with response surface methodology, Comput. Chem. Eng., vol. 29, no. 10, pp. 2155–2162, 2005, doi: 10.1016/j.compchemeng.2005.07.011
  7. B. Wang, D. L. Xu, K. W. Chu, and A. B. Yu. (2006). Numerical study of gas-solid flow in a cyclone separator, Appl. Math. Model., vol. 30, no. 11, pp. 1326–1342, 2006, doi: 10.1016/j.apm.2006.03.011
  8. M. E. Caliskan, I. Karagoz, A. Avci, and A. Surmen. (2019). Investigation into the effects of various parameters on the performance and classification potential of a cyclone classifier, Powder Technol., vol. 356, pp. 102–111, 2019, doi: 10.1016/j.powtec.2019.07.104
  9. Y. Zhu and K. W. Lee. (1999). Experimental study on small cyclones operating at high flowrates, J. Aerosol Sci., vol. 30, no. 10, pp. 1303–1315, 1999, doi: 10.1016/S0021-8502(99)00024-5
  10. M. Azadi, M. Azadi, and A. Mohebbi. (2010). A CFD study of the effect of cyclone size on its performance parameters, J. Hazard. Mater., vol. 182, no. 1–3, pp. 835–841, 2010, doi: 10.1016/j.jhazmat.2010.06.115
  11. K. W. Chu, B. Wang, D. L. Xu, Y. X. Chen, and A. B. Yu. (2010). CFD-DEM simulation of the gas-solid flow in a cyclone separator, Chem. Eng. Sci., vol. 66, no. 5, pp. 834–847, 2011, doi: 10.1016/j.ces.2010.11.026
  12. K. Elsayed and C. Lacor. (2011). Numerical modeling of the flow field and pe