Konvansiyonel sirkuler sistemle koaksiyel sirkuler sistemin karşılaştırılması

Comparison of the coaxial circle circuit with the conventional circle circuit

Pages
92–98
Publication Date
2022-10-18
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The temperature of inspired gas (Centigrade) in the treated group was higher than in the control group (p

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: The coaxial circle system helps prevent heat loss during surgery, and it also acts as a humidifier.
📊
Key Findings & Data:The coaxial circle system was used in the treated group (n=20), whereas the conventional circuit system was used in the control group (n=20).
💡
Conclusion & Impact:The temperature of inspired gas (Centigrade) in the treated group was higher than in the control group (p
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Objective: The coaxial circle system helps prevent heat loss during surgery, and it also acts as a humidifier. This study aimed to compare the coaxial breathing system and the conventional system in their ability to warm and moisturize inhaled gases, and we also analyzed lung function protection and saccharin clearance time in patients who underwent tympanomastoidectomy (TMT) with the aid of these two systems. Materials and Methods: Forty adult patients of ASA physical status I-II were scheduled for elective TMT. A standard volume-dependent ventilator setting was used to establish normocapnia. The coaxial circle system was used in the treated group (n=20), whereas the conventional circuit system was used in the control group (n=20). Saccharin clearance, VC (vital capacity), FRC (functional residual capacity), FEV1 (forced expiratory volume in 1 second), airway pressure, relative humidity and temperature of inspired gas, body temperature and adverse and hemodynamic effects were measured at different perioperative periods. Results: The relative humidity (mg H2O Lt -1) of inspired gas in the treated group was higher than in the control group at 5, 15, 30, 45, 60 and 90 minutes after anesthesia induction. The temperature of inspired gas (Centigrade) in the treated group was higher than in the control group (p

Özet

Amaç: Koaksiyel halka sisteminin kullanılması cerrahi sırasındaki ısı kaybını önler. Ki o bir nemlendirici olarak rol oynar. Bu çalışma timpanomastoidektomi (TMT) operasyonu geçiren hastalarda Konvensiyonel sistem ve koaksiyel sistemin, sakarin klirens zamanı ve akciğer fonsiyon testlerinin korunması ve inhale edilmiş gazın ısınma ve nemlenmesinin karşılaştırılmasını amaçlamıştır. Gereç ve Yöntem: Elektif timpanomastoidektomi yapılan ASA I-II fiziksel statüsünde yetişkin 40 hasta seçildi. Normokapniyi sağlamak için standart volüm ayarlı ventilatör kullanıldı.Tedavi grubunda (n=20), koaksiyel halka sistemi,kontrol grubunda (n=20) Konvensiyonel halka sistemi kullanıldı. Farklı peroperatif dönemlerde, Sakkarin klirens zamanı, VC, FRC, FEV1, hava yolu basıncı, inhale edilmiş gazın ısısı ve nisbi nemi, vücut ısısı hemodinamik etkiler ve yan etkiler ölçüldü. Bulgular: İnspire edilmiş gazın nisbi nemi anestezinin 5, 10,15, 30, 45 ve 90. dakikalarında tedavi grubunda kontrol grubundan daha yüksek bulundu. İnspire edilmiş gazın ısısı anestezinin 5, 10,15, 30, 45 ve 90. dakikalarında tedavi grubunda kontrol grubundan daha yüksek bulundu (p

🔖

Cite This Article

BİLGİ, M., GANİDAĞLI, S., KARATAŞ, E., KORUK, S., ŞAHİN, L., ÖNER, Ü., MIZRAK, A., GÜL, R. (2022). Konvansiyonel sirkuler sistemle koaksiyel sirkuler sistemin karşılaştırılması. Eurasian Journal of Medicine, Cilt: 43 - Sayı: 2, 92–98. https://ajindex.com/articles/509257

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (15)

  1. Deniz M, Uslu C, Ogredik EA, et al. Nasal mucociliary clearance in total laryngectomized patients. Eur Arch Otorhinolaryngol 2006; 263: 1099-104
  2. Kesımcı E, Bercın S, Kutluhan A, et al. Volatile anesthetics and mucociliary clearance. Minerva Anestesiol 2008; 74: 107-11
  3. Nakagawa NK, Franchını ML, Drıusso P, et al. Mucociliary clearance is impaired in acutely ill patients. Chest 2005; 128: 2772-7
  4. Naxakıs S, Athanasopoulos I, Vlastos IM, et al. Evaluation of nasal mucociliary clearance after medical or surgical treatment of chronic rhinosinusitis. Eur Arch Otorhinolaryngol 2009; 266: 1423-6
  5. Plaza VP, Carrıon VF, Marın PJ, et al. Saccharin test for the study of mucociliary clearance: reference values for a Spanish population. Arch Bronconeumol 2008; 44: 540-5
  6. Uslu H, Uslu C, Varoglu E, et al. Effects of septoplasty and septal deviation on nasal mucociliary clearance. International journal of clinical practice 2004; 58: 1108-11
  7. Bush A, Cole P, Harırı M, et al. Primary ciliary dyskinesia: diagnosis and standards of care. Eur Respir J 1998; 12: 982-8
  8. Tsang KW, Rutman A, Kanthakumar K, et al. Haemophilus influenzae infection of human respiratory mucosa in low concentrations of antibiotics. Am Rev Respir Dis 1993; 148: 201-7
  9. Yang J, Lıu B, Cao Z. The effects on nasal mucociliary clearance system of excising partial inferior turbinectomy with HUMMER or microwave. Lin Chung Er Bi Yan Hou Tou Jing Wai Ke Za Zhi 2007; 21: 213-6
  10. Chalon J, Tayyab MA, Ramanathan S. Cytology of respiratory epithelium as a predictor of respiratory complications after operation. Chest 1975; 67: 32-5
  11. Branson RD, Davıs K Jr, Campbell RS et al. Humidification in the intensive care unit. Prospective study of a new protocol utilizing heated humidification and a hygroscopic condenser humidifier. Chest 1993; 104: 1800-5
  12. Craven DE, Goularte TA, Make BJ. Contaminated condensate in mechanical ventilator circuits. A risk factor for nosocomial pneumonia? Am Rev Respir Dis 1984; 129: 625-8
  13. Chalon J, Simon R, Ramanathan S, et al. A high-humidity circle system for infants and children. Anesthesiology 1978; 49: 205-7
  14. Chalon J, Loew DA, Malebranche J. Effects of dry anesthetic gases on tracheobronchial ciliated epithelium. Anesthesiology 1972; 37: 338-43
  15. Szypula KA, Ip JK, Bogod D, et al. Detection of inner tube defects in co-axial circle and Bain breathing systems: a comparison of occlusion and Pethick tests. Anaesthesia 2008; 63: 1092-5