To familiarize non-imaging specialists with the role of MDCTin TAVR, we provide a concise overview of our approach to using this modality for the pre-proceduralassessment of TAVR candidates.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Transcatheter aortic valve replacement (TAVR) initially emerged as an alternative option to surgical aorticvalve replacement (SAVR) for patients with severe aortic stenosis who were considered either inoperable orhigh-risk for surgery.
📊
Key Findings & Data:However, since its advent the role of TAVR has been continuously evolving on the basisof clinical trials which showed that TAVR is non-inferior to SAVR in patients with moderate as well as lowrisk for surgery.
💡
Conclusion & Impact:To familiarize non-imaging specialists with the role of MDCTin TAVR, we provide a concise overview of our approach to using this modality for the pre-proceduralassessment of TAVR candidates.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Transcatheter aortic valve replacement (TAVR) initially emerged as an alternative option to surgical aorticvalve replacement (SAVR) for patients with severe aortic stenosis who were considered either inoperable orhigh-risk for surgery. However, since its advent the role of TAVR has been continuously evolving on the basisof clinical trials which showed that TAVR is non-inferior to SAVR in patients with moderate as well as lowrisk for surgery. Because of recent technological advances, multidetector computer tomography (MDCT) isinherently suitable for the pre-procedural assessment of patients being considered for TAVR within a veryshort imaging time, MDCT can measure the diameter of the aortic annulus, provide detailed informationregarding the status of the entire thoracoabdominal aorta, and assess the caliber of the peripheral vasculature used for transcatheter heart valve delivery. This information helps interventionists make optimal preprocedural decisions and avoid complications. To familiarize non-imaging specialists with the role of MDCTin TAVR, we provide a concise overview of our approach to using this modality for the pre-proceduralassessment of TAVR candidates.

🔖

Cite This Article

DURAN, C., DURAN, A., MASOOD, I., FRANK, L., SALEEM, A., MUTHUPILLAI, R., CHEONG, B. Y. C. (2022). Multidetector Computed Tomography (MDCT) Angiography in the Pre-Procedural Assessment of Patients Undergoing Transcatheter Aortic Valve Replacement. Eurasian Journal of Medicine, Cilt: 52 - Sayı: 1, 86–93. https://ajindex.com/articles/508906

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. Carabello BA, Paulus WJ. Aortic stenosis. Lancet 2009
  2. [CrossRef] 2. Go AS, Mozaffarian D, Roger VL, et al. Heart disease and stroke statistics--2014 update: a report from the American Heart Association. Circulation 2014
  3. e28-e292. 3. Brennan JM, Edwards FH, Zhao Y, O'Brien SM, Douglas PS, Peterson ED. Long-term survival after aortic valve replacement among high-risk elderly patients in the United States: insights from the Society of Thoracic Surgeons Adult Cardiac Surgery Database, 1991 to 2007. Circulation 2012
  4. [CrossRef] 4. Leon MB, Smith CR, Mack M, et al. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med 2010
  5. [CrossRef] 5. Aksoy M, Ince I, Ahiskalioglu A, Dogan N, Colak A, Sevimli S. Transcatheter Aortic Valve Implantation: First Applications and Short Term Outcomes in Our Clinic. Eurasian J Med 2015
  6. [CrossRef] 6. Leon MB, Smith CR, Mack MJ, et al. Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients. N Engl J Med 2016
  7. [CrossRef] 7. Popma JJ, Deeb GM, Yakubov SJ, et al. Transcatheter Aortic-Valve Replacement with a SelfExpanding Valve in Low-Risk Patients. N Engl J Med 2019
  8. [CrossRef] 8. Mack MJ, Leon MB, Thourani VH, et al. Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients. N Engl J Med 2019
  9. [CrossRef] 9. Tanaka R, Yoshioka K, Niinuma H, Ohsawa S, Okabayashi H, Ehara S. Diagnostic value of cardiac CT in the evaluation of bicuspid aortic stenosis: comparison with echocardiography and operative findings. AJR Am J Roentgenol 2010
  10. [CrossRef] 10. Wijesinghe N, Ye J, Rodés-Cabau J, et al. Transcatheter aortic valve implantation in patients with bicuspid aortic valve stenosis. JACC Cardiovasc Interv 2010
  11. [CrossRef] 11. Koos R, Mahnken AH, Dohmen G, et al. Association of aortic valve calcification severity with the degree of aortic regurgitation after transcatheter aortic valve implantation. Int J Cardiol 2011
  12. [CrossRef] 12. John D, Buellesfeld L, Yuecel S, et al. Correlation of device landing zone calcification and acute procedural success in patients undergoing transcatheter aortic valve implantations with the self-expanding CoreValve prosthesis. JACC Cardiovasc Interv 2010
  13. [CrossRef] 13. Haensig M, Lehmkuhl L, Rastan AJ, et al. Aortic valve calcium scoring is a predicto