Journals / Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi / 2019 / Cilt: 12 - Sayı: 3

Lβ/LD Intensity Ratios of Antimony at Different Azimuthal and Polar Angles

Farklı Azimuthal ve Saçılma Açılarında Antimonun Lβ/LD Şiddet Oranları

Pages
1504–1512
Publication Date
2022-10-11
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

In the purpose of exciting to Sband detecting the X-rays emitted from Sb, 241 Am point source and Si(Li) detector have been used, respectively.The data was analysed by means of Origin 9 Software and it was determined that Lβ/LD change by polarscattering angle at a fixed azimuthal scattering angle and by azimuthal scattering angle at a fixed polar scatteringangle.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Lβ/LD X-ray intensity ratios of antimony (Sb) were investigated at different azimuthal (-30° ≤ φ ≤+30°, atintervals of 10°) and polar scattering angles (85°≤ θ ≤135° at intervals of 10°).
📊
Key Findings & Data:Lβ/LD X-ray intensity ratios of antimony (Sb) were investigated at different azimuthal (-30° ≤ φ ≤+30°, atintervals of 10°) and polar scattering angles (85°≤ θ ≤135° at intervals of 10°).
💡
Conclusion & Impact:In the purpose of exciting to Sband detecting the X-rays emitted from Sb, 241 Am point source and Si(Li) detector have been used, respectively.The data was analysed by means of Origin 9 Software and it was determined that Lβ/LD change by polarscattering angle at a fixed azimuthal scattering angle and by azimuthal scattering angle at a fixed polar scatteringangle.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Lβ/LD X-ray intensity ratios of antimony (Sb) were investigated at different azimuthal (-30° ≤ φ ≤+30°, atintervals of 10°) and polar scattering angles (85°≤ θ ≤135° at intervals of 10°). In the purpose of exciting to Sband detecting the X-rays emitted from Sb, 241 Am point source and Si(Li) detector have been used, respectively.The data was analysed by means of Origin 9 Software and it was determined that Lβ/LD change by polarscattering angle at a fixed azimuthal scattering angle and by azimuthal scattering angle at a fixed polar scatteringangle.

Özet

Sb’ nin Lβ / LD X-ışını şiddet oranları farklı azimuthal ve saçılma açılarında ölçüldü. Sb’ yi uyarmak amacıyla ve Sb’den gelen X-ışınların saymak amacıyla 241 Am nokta kaynak ve Si(Li) dedektör sırasıyla kullanıldı. Datalar Origin 9 programı aracılığıyla analiz edildi ve Lβ / LD şiddet oranlarının farklı azimuthal açı ve saçılma açısı değerleriyle değiştiği belirlendi.

🔖

Cite This Article

UĞURLU, M. (2022). Lβ/LD Intensity Ratios of Antimony at Different Azimuthal and Polar Angles. Erzincan Üniversitesi Fen Bilimleri Enstitüsü Dergisi, Cilt: 12 - Sayı: 3, 1504–1512. https://ajindex.com/articles/505476

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (11)

  1. Akkuş, T. Şahin, Y. Yılmaz, D. Tuzluca, F. N. 2016. The K-beta/K-alpha intensity ratios of some elements at different azimuthal scattering angles at 59.54 keV. Canadian Journal of Physic, 94, 1–5.
  2. Akkuş, T. Şahin, Y. Yılmaz, D. 2016. Azimuthal and polar angle dependence of L X-ray differential cross-sections of Yb at 59.54keV photon energy. Nuclear Instruments and Methods in Physics Research B, 366, 145–149.
  3. Cesareo, R. Rizzutto, M. A. Brunetti, A. Rao, D. V. 2009. Metal location and thickness in a multilayered sheet by measuring KD/Kβ, LD/Lβ and LD/Lγ X-ray ratios. Nuclear Instruments and Methods in Physics Research B, 267, 2890-2896.
  4. Cooper, J. Zare, N. 1969. Photoelectron angular distribution. Lectures on Theoretical Physics. X1C, 317–337.
  5. Demir, D. Şahin, Y. 2007. Measurement of L X-Ray Intensity Ratios for 92U and 90Th Elements Using Photoionization in an External Magnetic Field. Chinese Physics Letters, 24, 668-671.
  6. Doğan, O. Şimşek, Ö. Turgut, Ü. Ertuğrul, M. 1998. L X-ray intensity ratios in heavy elements at 59.5 and 122 keV photons. Journal of Radioanalytical and Nuclear Chemistry, 232, 143-146.
  7. Ertuğrul, M. 1996. Measurement of crosssections and Coster-Kronig transition effect on L subshell X-rays of some heavy elements in the atomic range 79 ≤ Z ≤92 at 59.5 keV. Nuclear Instruments and Methods in Physics Research B, 119, 345- 351. Flügge, S. Melhorn, W. Schmidt, V. 1972. Angular distribution of auger electrons following photoionization. Physical Review Letter, 29, 7–9.
  8. Gerward, L. Guilbert, N. Jensen, K. B. Levring, H. 2001. X-ray absorption in matter, reengineering XCOM. Radiation Physics and Chemistry, 60, 23-24.
  9. Gerward, L. Guilbert, N. Jensen, K. B. Levring, H. 2004. WinXCom-a program for calculating X-ray attenuation coefficients. Radiation Physic and Chemistry, 71, 653– 654. Han, I. Sahin, M. Demir, L. 2008. Angular variations of K and L X-ray fluorescence cross sections for some lanthanides. Canadian Journal of Physic, 86, 361–367.
  10. Han, I. Sahin, M. Demir, L. 2009. The polarization of X-rays and magnetic photoionization cross-sections for L3 subshell. Applied Radiaion and Isotopes, 67, 1027–1032.
  11. Kawai, J. 2001.Intensıty Ratıo of Transıtıon-Metal La and Lb Lınes. The Rigaku Journal, 18, 31-37Krause, M. O. 1979. X-Ray Fluorescence Cross Sections for K and L X Rays of the Elements. Journal of Physical and Chemical Reference Data, 8, 3307. Kahlon, K. S. Aulakh, H. S. Singh, N. Mittal, R. Allawadhi, K.L. Sood, B. S. 1991. Measurement of angu