Journals / Düzce Üniversitesi Bilim ve Teknoloji Dergisi / 2020 / Cilt: 8 - Sayı: 1

Accuracy and Repeatability Performance of Prototype Linear Delta Robot

Prototip olarak Tasarlanan Lineer Delta Robotun Doğruluk ve Tekrarlanabilirlik Performansı

Pages
869–879
Publication Date
2022-10-12
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

As a result, the tests are similar to those in the literature because they are performed by open loop control method.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:The linear delta robot, which is a family of parallel kinematic mechanisms, is a robot consisting of a fixed and a moving platform, driven by 3 linear actuators.
📊
Key Findings & Data:In this study, accuracy and repeatability performance of linear delta robot was performed.
💡
Conclusion & Impact:As a result, the tests are similar to those in the literature because they are performed by open loop control method.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

The linear delta robot, which is a family of parallel kinematic mechanisms, is a robot consisting of a fixed and a moving platform, driven by 3 linear actuators. In this study, accuracy and repeatability performance of linear delta robot was performed. Experimental design for linear delta robots was established and average accuracy and repeatability parameters according to ISO 9283 standard were found to be robot's performance by using Microscribe G2X coordinate measuring device. In the tests, the average accuracy of the robot is 1.25 mm and the average repeatability is 1.45 mm. As a result, the tests are similar to those in the literature because they are performed by open loop control method.

Özet

Paralel kinematik mekanizmalar ailesinden olan lineer delta robot, 3 adet lineer aktüatör ile hareket ettirilen, birsabit ve bir hareketli platformdan oluşan bir robottur. Bu çalışmada, lineer delta robotun prototipi yapılarakdoğruluk ve tekrarlanabilirlik performansı gerçekleştirilmiştir. Lineer delta robot için deney tasarımı düzeneğikurulmuş ve ISO 9283 standardına göre ortalama doğruluk ve tekrarlanabilirlik parametreleri Microscribe G2Xkoordinat ölçme cihazı kullanılarak robotun performansı bulunmuştur. Yapılan testlerde robotun ortalamadoğruluğu 1,25 mm ve ortalama tekrarlanabilirliği ise 1,45 mm bulunmaktadır. Sonuç olarak yapılan testler açıkçevrim kontrol metoduyla yapıldığı için literatürdeki çalışmalara benzerlik göstermektedir.

🔖

Cite This Article

AYYILDIZ, M., AYYILDIZ, E. A. (2022). Accuracy and Repeatability Performance of Prototype Linear Delta Robot. Düzce Üniversitesi Bilim ve Teknoloji Dergisi, Cilt: 8 - Sayı: 1, 869–879. https://ajindex.com/articles/494079

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (13)

  1. D. Ku, “Direct displacement analysis of a stewart platform mechanism,” Mechanism and Machine Theory, vol. 34, no. 3, pp. 453-465, 1999
  2. H. Alp, “Sezgisel yöntemlerle paralel mekanizmaların çalışma uzayı analizi,” Doktora Tezi, Fen Bilimleri Enstitüsü, İstanbul Teknik Üniversitesi, İstanbul, Türkiye, 2007
  3. M. Weck and D. Staimer, “Parallel kinematic machine tools – current state and future potentials,” CIRP Annals - Manufacturing Technology, vol. 51, no. 2, pp. 671-683, 2002
  4. X. Hu, “Design and analysis of a three degrees of freedom parallel kinematic machine,” M. Sc. Thesis, The Faculty of Engineering and Applied Science Mechanical Engineering Program University of Ontario Institute of Technology, North Oshawa, 2008
  5. S. Yiğit, “Paralel manipülatörlerin uzaysal vektör cebri yöntemiyle kinematik modellemesi,” Yüksek Lisans Tezi, Fen Bilimleri Enstitüsü, İstanbul Üniversitesi, İstanbul, Türkiye, 2013
  6. Y. Karabulut, “Dokunmatik ekranlı cihazlar için görüntü işlemeye dayalı robotik test otomasyon sistemi geliştirilmesi,” Yüksek Lisans Tezi, Fen Bilimleri Enstitüsü, Manisa Celal Bayar Üniversitesi, Manisa, Türkiye, 2016
  7. C. He, K. Olds, I. Iordachita and R. Taylor, “A new ENT microsurgery robot: error analysis and implementation,” IEEE International Conference on Robotics and Automation, Germany, 2013, pp. 1221-1227
  8. Y. Meng and Z. Zhuang, “Self-calibration of camera-equipped robot manipulators,” The International Journal of Robotics Research, vol. 20, no. 11, pp. 909-921, 2001
  9. M.R. Driels, L.W. Swayze and L.S. Potter, “Full-pose calibration of a robot manipulator using a coordinate-measuring machine,” The International Journal of Advanced Manufacturing Technology, vol. 8, no. 1, pp. 34-44, 1993
  10. C. Lightcap, S. Hamner, T. Schmitz and S. Banks, “Improved positioning accuracy of the PA10-6CE robot with geometric and flexibility calibration,” IEEE Transactions on Robotics, vol. 24, no. 2, pp. 452-456, 2008
  11. A. Nubiola, “Calibration of a serial robot using a laser tracker,” PhD Thesis, École De Technologie Supérieure, Canada, 2011
  12. M. Slamani, A. Joubair and I.A. Bonev, “A comparative evaluation of three industrial robots using three reference measuring techniques,” Industrial Robot: An International Journal, vol. 42, no. 6, pp. 572-585, 2015
  13. J. Semjon, M. Sukop, M. Vagas, R. Janos, P. Tuleja, L. Koukolova and J. Varga, “Comparison of the delta robot ABB IRB 360 properties after collisions,” Communications-S