Effect of different crown removing procedures on the implant stability quotient and removal torque values of dental implants

Pages
314–319
Publication Date
2021-06-30
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

Conclusion: The crown-removal procedure has significantly unfavorable effect on the implant stability quotient values of the implants, whereas removal torque values of the implants was not affected crown-removal procedures.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: To investigate the effects of different crown-removal methods on the osseointegration of dental implants in implant-retained single crowns.
📊
Key Findings & Data:After 28 days, resonance frequency analysis was performed on the implants to detect the degree of osseointegration; 24 hours later, the sacrificed tibias were divided into 3 groups according to different crown-removal methods: crown removal with a diamond bur, the use of a spring-loaded crown remover, and the use of a pneumatic crown remover.
💡
Conclusion & Impact:Conclusion: The crown-removal procedure has significantly unfavorable effect on the implant stability quotient values of the implants, whereas removal torque values of the implants was not affected crown-removal procedures.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:dental implant · crown removal · RFA

Abstract

Objective: To investigate the effects of different crown-removal methods on the osseointegration of dental implants in implant-retained single crowns. Methods: Two implants were inserted in each tibia of each New Zealand rabbit’s rear legs. After 28 days, resonance frequency analysis was performed on the implants to detect the degree of osseointegration; 24 hours later, the sacrificed tibias were divided into 3 groups according to different crown-removal methods: crown removal with a diamond bur, the use of a spring-loaded crown remover, and the use of a pneumatic crown remover. Following the crown-removal procedures, the implants’ resonance frequency analysis values and removal torque values were measured. Results: No significant difference in implant stability quotient was measured after crown removal for either group of diamond bur or group of pneumatic crown remover (p=0.677 and p=0.918, respectively). However, there was a statistically significant difference in implant stability quotient after crown removal for group of spring-loaded crown remover (p=0.008). Moreover, no significant difference was detected between the groups’ removal torque values (p>0.05). Conclusion: The crown-removal procedure has significantly unfavorable effect on the implant stability quotient values of the implants, whereas removal torque values of the implants was not affected crown-removal procedures.

🔖

Cite This Article

AKIN, H., ÜNAL, Y., YİLMAZER, K. (2021). Effect of different crown removing procedures on the implant stability quotient and removal torque values of dental implants. Clinical and Experimental Health Sciences, Cilt: 11 - Sayı: 2, 314–319. https://ajindex.com/articles/481598

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (14)

  1. Ma S, Fenton A. Screw- versus cement-retained implant prostheses: a systematic review of prosthodontic maintenance and complications. Int J Prosthodont 2015; 28:127-145
  2. Mehl C, Harder S, Schwarz D, et al. In vitro influence of ultrasonic stress, removal force preload and thermocycling on the retrievability of implant-retained crowns. Clin Oral Implants Res 2012; 23:930-937
  3. Lemos CA, de Souza Batista VE, Almeida DA, et al. Evaluation of cement-retained versus screw-retained implant-supported restorations for marginal bone loss: A systematic review and meta-analysis. J Prosthet Dent 2015; 115:419-427
  4. Sailer I, Mühlemann S, Zwahlen M, et al. Cemented and screw-retained implant reconstructions: a systematic review of the survival and complication rates. Clin Oral Implants Res 2012; 23(Suppl 6):163-201
  5. Garg P, Pujari M, Prithviraj DR, et al. Retentiveness of various luting agents used with implant-supported prosthesis: an in vitro study. J Oral Implantol 2014; 40:649-654
  6. Akin H, Guney U. Effect of various surface treatments on the retention properties of titanium to implant restorative cement. Lasers Med Sci 2012; 27:1183-1187
  7. Worni A, Gholami H, Marchand L, et al. Retrievability of implant-supported crowns when using three different cements: a controlled clinical trial. Int J Prosthodont 2015; 28:22-29
  8. Mehl C, Harder S, Wolfart M, et al. Retrievability of implant-retained crowns following cementation. Clin Oral Impl Res 2008; 19:1304–1311
  9. Ormianer Z, Schiroli G. Maxillary single-tooth replacement utilizing a novel ceramic restorative system: results to 30 months. J Oral Implantol 2006; 32:190–199
  10. Freitas AC Jr, Bonfante EA, Martins LM, et al. Reliability and failure modes of anterior single-unit implant-supported restorations. Clin Oral Implants Res 2012; 23:1005–1011
  11. Mangano C, Mangano F, Piattelli A, et al. Prospective clinical evaluation of 307 singletooth morse taper-connection implants: amulticenter study. Int J Oral Maxillofac Implants 2010; 25:394–400
  12. Pjetursson BE, Bragger U, Lang NP, et al. Comparison of survival and complication rates of tooth-supported fixed dental prostheses (FDPs) and implant-supported FDPs and single crowns (SCs). Clin Oral Implants Res 2007; 18(Suppl 3):97–113
  13. Janardanan K, Varkey VK, Lovely M, et al. Coronal disassembly systems and techniques: An overview. J Interdiscip Dentistry 2014; 4:33-40
  14. Polat Sağsöz N, Yanıkoğlu N, Aladağ Lİ, et al. The investigation of reasons