A new spectrophotometric study with ortho hydroxy schiff base for the determination of aluminum in drug

Pages
456–461
Publication Date
2022-10-12
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

TheLOD and LOQ values of the developed method were 0.01139 μg mL-1 and 0.0345 μg mL-1,respectively for the ligand.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:In this study, a Schiff base called (E)-2-((2- hydroxy -3- methoxy benzylidene)amino)-5-methylphenol (L) was used as a ligand.
📊
Key Findings & Data:The absorbance of Al(III)-L complex obeys Beer’s law between 1.4 μgmL–1 and 13.5 μg mL–1 for the aluminium in the optimum conditions.
💡
Conclusion & Impact:TheLOD and LOQ values of the developed method were 0.01139 μg mL-1 and 0.0345 μg mL-1,respectively for the ligand.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

In this study, a Schiff base called (E)-2-((2- hydroxy -3- methoxy benzylidene)amino)-5-methylphenol (L) was used as a ligand. Spectrophotometric properties of the ligand have beendefined and the optimum conditions for determining aluminium by complex by UV-Vis.spectrophotometry. The absorbance of Al(III)-L complex obeys Beer’s law between 1.4 μgmL–1 and 13.5 μg mL–1 for the aluminium in the optimum conditions. Under optimumconditions, the determination of aluminium in Kompensan® drug was done successfully. TheLOD and LOQ values of the developed method were 0.01139 μg mL-1 and 0.0345 μg mL-1,respectively for the ligand.

🔖

Cite This Article

GÜRAY, T., UYSAL, Ü. D., ERCENGİZ, D. (2022). A new spectrophotometric study with ortho hydroxy schiff base for the determination of aluminum in drug. Cumhuriyet Science Journal, Cilt: 41 - Sayı: 2, 456–461. https://ajindex.com/articles/477713

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. Farndon, J. The elements. Aluminum. Benchmark Books, 2001, New York
  2. Nayak, P. Aluminium: impacts and disease. Environmental Research. 89(2) (2002) 101– 115
  3. Santarossa, D. G., Talio, M. C. and Fernández, L. P. Aluminium traces determination in biological and water samples using a novel extraction scheme combined with molecular fluorescence. Microchem. J., 129 (2016) 274- 280
  4. Minshall, C., Nadal, J. and Exley, C. Aluminium in human sweat. J.Trace Elem. Med. and Bio., 28 (1) (2014) 87-88
  5. Antoine, J. M. R., HooFung, L. A., Grant, C. N. Assessment of the potential health risks associated with the aluminium, arsenic, cadmium and lead content in selected fruits and vegetables grown in Jamaica. Toxicology Reports, 4 (2017) 181 -187
  6. Frankowski, M. Aluminium and Its Complexes in Teas and Fruity Brew Samples, Speciation and Ions Determination by Ion Chromatography and High-Performance Liquid Chromatography–Fluorescence Analytical Methods. Food Analy. Met., 7 (5) (2014) 1109– 1117
  7. Kalogria, E., Varvaresou, A., Papageorgiou, S., Protopapa, E., Tsaknis, I., Matikas, A. and Panderi, I. Pre-Column Derivatization HPLC Procedure for the Quantitation of Aluminium Chlorohydrate in Antiperspirant Creams Using Quercetin as Chromogenic Reagent. Chromatographia, 77 (19-20) (2014) 1275- 1281
  8. Hydes, D. J. and Liss, P. S. Fluorimetric Method for the Determination of Low Concentrations of Dissolved Aluminium in Natural Waters. Analyst, 101 (1976) 922- 931
  9. Pedrozo-Peñafiel, M.J., Doyle, A., Mendes, L.A.N., Tristão, M.L.B., Saavedra, A. and Aucelio, R.Q. Methods for the determination of silicon and aluminum in fuel oils and in crude oils by X-ray fluorescence spectrometry. Fuel, 243 (2019) 493- 500
  10. Qiong, L., Lirong, W., Danli, X. and Guanghan L. Determination of trace aluminum in foods by stripping voltammetry. Food Chem., 97(1) (2006) 176-180
  11. Ritchie, G.S.P., Posner, A.M., and Ritchie, I.M. The determination of trace levels of aluminum by differential pulse polarography. Anal. Chim. Acta, 117, (1980) 233-239, [12] Eroglu E. I., Gulec, A. and Ayaz A. Determination of aluminium leaching into various baked meats with different types of foils by ICP‐MS. J. Food Process. Preserv., 42 (12) (2018) 1-9