Journals / Cumhuriyet Dental Journal / 2013 / Cilt: 16 - Sayı: 1

Fabricating a hollow bulb obturator

Pages
61–65
Publication Date
2022-10-11
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The patient s functional and esthetic expectations were satisfied.

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Obturators are generally used in the rehabilitation of the maxillectomy defects.
📊
Key Findings & Data:In this case, a 65-year-old male patient underwent surgical removal of left part of the maxilla due to the squamous cell carcinoma.
💡
Conclusion & Impact:The patient s functional and esthetic expectations were satisfied.
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Obturators are generally used in the rehabilitation of the maxillectomy defects. Ideally, obturators should be light, properly fit and construction should be made easily. By decreasing the weight of the prosthesis, the retention and stability may be optimized to allow the obturator for function comfortably during mastication, phonation, and deglutition. In this case, a 65-year-old male patient underwent surgical removal of left part of the maxilla due to the squamous cell carcinoma. In this technique fabrication of a hollow bulb obturator prosthesis as a single unit in heat-cured acrylic resin using a single-step flasking procedure was described. The patient s functional and esthetic expectations were satisfied.

🔖

Cite This Article

SARI, F., TUNÇDEMİR, A. R. (2022). Fabricating a hollow bulb obturator. Cumhuriyet Dental Journal, Cilt: 16 - Sayı: 1, 61–65. https://ajindex.com/articles/477171

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (16)

  1. Andrew KS, Rothenberger S, Minsley GE. An innovative investment method for the fabrication of a closed hollow obturator prosthesis. J Prosthet Dent 1998;80:129-132
  2. Asher ES, Psillakis J, Piro JD, Wright RF. Technique for quick conversion of an obturator into a hollow bulb. J Prosthet Dent 2001;85:419-420
  3. Athel M, Jagger R, Jagger D. Effect of ageing on the bond strength of a permanent denture soft lining material. J Oral Rehabil 2002;29:992-996
  4. Ortegon SM, Martin JW, Lewin JS. A hollow delayed surgical obturator for a bilateral subtotal maxillectomy patient: a clinical report. J Prosthet Dent 2008;99:14-18
  5. Oh W, Roumanas E. Dental implant– assisted prosthetic rehabilitation of a patient with a bilateral maxillectomy defect secondary to mucormycosis. J Prosthet Dent 2006;96:88-95
  6. Beumer J, Curtis TA. Marunick MT. Maxillofacial rehabilitation: Prosthodontic and surgical considerations. St. Louis: Ishiyaku Euro America 1996;240-282
  7. Chalian VA., Drane JB., Standısh SM., Maxillofacial Prosthetics. Multidisciplinary practice, The Williams & Wilkins Co., Baltimore. 197, p.133-148
  8. Keyf F. Obturator prostheses for hemimaxillectomy patients: Review. J Oral Rehabil 2001;28;821-829 9. Mutluay MM, Oguz S, Fløystrand F, Saxegaard E, Dogan A, Bek B, Ruyter IE. A prospective study on the clinical performance of polysiloxane soft liners: one-year results. Dent Mater J 2008;27:440- 447
  9. Phankosol P, Martin JW. Hollow obturator with removal lid. J Prosthet Dent 1985;54:98-100
  10. Elangovan S, Loibi E. Two-piece hollow bulb obturator. Indian J Dent Res 2011;22:486-488 12. Rilo B, Dasilva JL, Ferros I, Mora MJ, Santana U. A hollow-bulb interim obturator for maxillary resection. A case report. J Oral Rehabil 2005;32:234-236
  11. Schneider A. Method of fabricating a hollow obturator. J Prosthet Dent 1978;40:351
  12. Urban VM, Machado AL, Oliveira RV, Vergani CE, Pavarina AC, Cass QB. Residual monomer of reline acrylic resins. Effect of water-bath and microwave post-polymerization treatments. Dent Mater 2007;23:363- 368
  13. Wang RR, Hirsch RF. Refining hollow obturator base using light- activated resin J Prosthet Dent 1997;78:327-329
  14. Wang RR. Sectional prosthesis for total maxillectomy patients: a clinical report. J Prosthet Dent 1997;78:241
  15. Wu YL, Schaaf NG. Comparison of weight reduction in different designs of solid and hollow obturator prostheses. J Prosthet Dent 1989 62:214-217
  16. Habib BH, Driscoll CF. Fabrication of a closed