Journals / Clinical and Experimental Health Sciences / 2020 / Cilt: 10 - Sayı: 4

Is Standard Urine Bag or Urofix? Which is More Usefull in Surgical Nursing Care? Accuracy of Urine Output Monitoring

Pages
423–427
Publication Date
2022-10-11
DOI
—
🏛️Bibliographic metadata and full text access for this article are provided via DergiPark.
DergiPark Record ↗
✨

AI Summary & Key Takeaways

AI Insight
⚡ TL;DR(Too Long; Didn't Read)

The difference was statistically significant in all measurements (p

📌 3 Key Takeaways

🎯
Objective & Hypothesis:Objective: The aim of this study is to evaluate and compare the accuracy of urine output measurement performed by standard urine bags and urofix.
📊
Key Findings & Data:Methods: This is a prospective study conducted at a 22-bed urology unit.
💡
Conclusion & Impact:The difference was statistically significant in all measurements (p
🔬Design:Research Article
📍Scope:Comprehensive Sample
⚙️Variables:Domain Parameters

Abstract

Objective: The aim of this study is to evaluate and compare the accuracy of urine output measurement performed by standard urine bags and urofix. Methods: This is a prospective study conducted at a 22-bed urology unit. Urine volume was measured either by a standard urine bag or urofix, verified by scaled container measurements in patients dressed with urinary catheter and expected to stay with it for 24 hours or more. In total, 1048 measurements were obtained for 131 patients. Results: The difference between median, maximum and minimum values of urine volumes from the scaled container and nurse’s forecast was evaluated for each of 4 measurements. When the urine volume was measured with the standard urine bag, the average volume was 550 cc in the first measurement while it was 300 cc with urofix. Mean values for the second, third and fourth measurements with standard urine bag and urofix were as follows respectively; 590 cc and 335 cc, 500 cc and 300 cc, 600 cc and 300 cc. The difference was statistically significant in all measurements (p

🔖

Cite This Article

Onler, E., Yildiz, T., Yazici, C. M., Turker, P., Malak, A., Eren, E. (2022). Is Standard Urine Bag or Urofix? Which is More Usefull in Surgical Nursing Care? Accuracy of Urine Output Monitoring. Clinical and Experimental Health Sciences, Cilt: 10 - Sayı: 4, 423–427. https://ajindex.com/articles/474315

📄 Full Text PDF Viewer

📄

PDF görüntüleyici hazırlanıyor...

References (12)

  1. Brugnolli A, Canzan F, Bevilacqua A, Marognolli O, Verlato G, Vincenzi S, Ambrosi E. Fluid therapy management in hospitalized patients: Results from a cross-sectional study. Clin Ther 2017; 39(2): 311-321
  2. Watson F, Austin P. Physiology of human fluid balance.Anaest Intensive Care Med 2018; 19(9): 494-501
  3. Lee J. Fluid and electrolyte disturbances in critically ill patients. Electrolyte Blood Press 2010; 8: 72-81
  4. Lobo DN, Dube MG, Neal KR, Allison SP, Rowlands BC. Perioperative fluid and electrolyte management: A survey of consultant surgeons in the UK. Ann R Coll Surg Engl 2002; 84: 156-160
  5. Lopes MR, Oliveira MA, Pereira VO, Lemos IP, Auler JO, Michard F. Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: a pilot randomized controlled trial. Crit Care 2007; 11(5): R1006
  6. Azhar RA, Bochner B, Catto J, Goh AC, Kelly J, Patel surgery: a contemporary systematic review of outcomes, key elements, and research needs. Eur Urol 2016; 70(1): 176-187
  7. Hersch M, Ainav S, Izbicki G. Accuracy and ease of use of a novel electronic urine output monitoring device compared with standard manual urinometer in the intensive care unit. J Crit Care 2009; 24: 629.e13-629
  8. Tok Özen A, Enç N. The role of nurses for changes in fluid- electrolyte balance in critical diseases. Turk J Card Nur 2013;4(5):9-13 (In Turkish)
  9. Joosten A, Huynh T, Suehiro K, Canales C, Cannesson M, Rinehart J. Goal-Directed fluid therapy with closed-loop assistance during moderate risk surgery using noninvasive cardiac output monitoring: A pilot study. Br J Anaesth 2015;114(6):886-892
  10. Grover C, Barney K. Operating safely in surgery and critical care with perioperative automation. JHIM 2004;18: 56-61
  11. Ricci Z, Cruz D, Ronco C. The RIFLE criteria and mortality in acute kidney injury: A systematic review. Kidney Int 2008; 73:538-546
  12. Otero A, Palacios F, Akinfiev T, Fernandez R. A device for automatically measuring and supervising the critical care patient’s urine output. Sensors (Basel). 2010; 10 (1): 934-951.